{"id":22027,"date":"2026-08-30T23:15:48","date_gmt":"2026-08-30T15:15:48","guid":{"rendered":"https:\/\/www.luleey.com\/?p=22027"},"modified":"2026-08-30T23:15:51","modified_gmt":"2026-08-30T15:15:51","slug":"can-you-use-two-identical-bidi-sfp-modules-together","status":"publish","type":"post","link":"https:\/\/www.luleey.com\/ar\/can-you-use-two-identical-bidi-sfp-modules-together\/","title":{"rendered":"\u0647\u0644 \u064a\u0645\u0643\u0646 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0648\u062d\u062f\u062a\u064a SFP \u0645\u062a\u0637\u0627\u0628\u0642\u062a\u064a\u0646 \u062a\u062f\u0639\u0645\u0627\u0646 \u0627\u0644\u0627\u062a\u062c\u0627\u0647\u064a\u0646 (BiDi) \u0645\u0639\u064b\u0627\u061f"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-9fc0c9c2\">In most common single-fiber Ethernet links, <strong>two identical <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/ar\/tag\/bidi-sfp\/\" title=\"View all posts in BiDi SFP\">SFP \u062b\u0646\u0627\u0626\u064a \u0627\u0644\u0627\u062a\u062c\u0627\u0647<\/a> modules<\/strong> will not work together. If both modules transmit at the same wavelength and listen at the same other wavelength, neither receiver sees the signal it is designed to receive.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8070d87e\">You normally need a complementary pair. For example, a module marked TX1310nm\/RX1550nm needs an opposite module marked TX1550nm\/RX1310nm.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-93019720\">The modules must also match in data application, line rate, reach class, connector and fiber type. Both host ports must support the required electrical mode and module coding.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-eec46cd5\">\u201cA\/B,\u201d \u201cU\/D\u201d and colored labels can help, but the safest method is to compare the actual TX and RX wavelength specifications.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-f5cf69c6\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22029\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-matched-pair-hero.avif\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-matched-pair-hero.avif 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-matched-pair-hero-800x800.avif 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-matched-pair-hero-400x400.avif 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-matched-pair-hero-768x768.avif 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-matched-pair-hero-12x12.avif 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-matched-pair-hero-150x150.avif 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ad92ef52\"><\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-6b46164d\">Two Identical BiDi SFP Modules: Quick Answer<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Local module<\/th><th>Remote module<\/th><th>Wavelength result<\/th><th>Expected outcome<\/th><\/tr><\/thead><tbody><tr><td>TX1310\/RX1550<\/td><td>TX1310\/RX1550<\/td><td>Both transmit 1310; both listen for 1550<\/td><td>No normal link<\/td><\/tr><tr><td>TX1310\/RX1550<\/td><td>TX1550\/RX1310<\/td><td>Each TX matches the other RX<\/td><td>Wavelength pairing is correct<\/td><\/tr><tr><td>TX1270\/RX1330<\/td><td>TX1330\/RX1270<\/td><td>Each TX matches the other RX<\/td><td>Wavelength pairing is correct<\/td><\/tr><tr><td>TX1310\/RX1550 at 1G<\/td><td>TX1550\/RX1310 at 2.5G<\/td><td>Wavelengths complement, rates do not<\/td><td>No normal link<\/td><\/tr><tr><td>Complementary wavelengths but different power classes<\/td><td>Wavelengths may match<\/td><td>Optical budget may be invalid<\/td><td>Verify exact specifications<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3a123bbb\">Correct wavelengths are necessary but not sufficient. A real link also depends on host SerDes mode, application rate, module coding, fiber, connector condition and received power.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-d0ecb218\">How a BiDi SFP Uses One Fiber Strand<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e48ac384\">A normal duplex optical link uses one fiber for each direction. A single-fiber BiDi module combines its transmitter and receiver onto one fiber through an internal wavelength-selective optical component.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a1fa330d\">One wavelength travels from Side A to Side B while a different wavelength travels from Side B to Side A.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1c768b39\">For one common vendor-specific pair:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Side A transmits at 1310nm and receives at 1550nm.<\/li>\n\n\n\n<li>Side B transmits at 1550nm and receives at 1310nm.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-09cbc3da\">Other products use different wavelength plans. Cisco documents 1000BASE-BX10-U as TX1310\/RX1490 and BX10-D as TX1490\/RX1310. Its 10G BXU\/BXD products use 1270nm and 1330nm in opposite directions. <a href=\"https:\/\/www.cisco.com\/c\/en\/us\/products\/collateral\/interfaces-modules\/gigabit-ethernet-gbic-sfp-modules\/datasheet-c78-366584.html\" target=\"_blank\" rel=\"noopener\">Cisco 1G BiDi specifications<\/a>, <a href=\"https:\/\/www.cisco.com\/c\/en\/us\/products\/collateral\/interfaces-modules\/transceiver-modules\/data_sheet_c78-455693.html\" target=\"_blank\" rel=\"noopener\">Cisco 10G BiDi specifications<\/a><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-fa17c5ca\">Do not assume that every BiDi pair uses 1310\/1550nm. Read the exact datasheet and label.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-4434d3f2\">Why Two Same-Side Modules Usually Fail<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-97a286c9\">Suppose both ends use TX1310\/RX1550 modules.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-aaec5c9f\">At the local end, the receiver is filtered for 1550nm. The remote module sends 1310nm, so the local receiver does not receive its intended wavelength.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d38ccc01\">The same mismatch happens in the other direction. Both transmitters send 1310nm, while both receivers wait for 1550nm.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-945cd1db\">The switch may still:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Detect the module EEPROM<\/li>\n\n\n\n<li>Display the vendor and part number<\/li>\n\n\n\n<li>Report temperature, voltage or TX power<\/li>\n\n\n\n<li>Show that the laser is enabled<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0afb3efa\">None of these proves that the remote optical wavelength reaches the correct receiver. Module detection and DDM communication are separate from successful optical traffic.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-e700bcac\">Does \u201cIdentical\u201d Always Mean the Link Cannot Work?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-523536c7\">For the common fixed-wavelength BiDi SFPs discussed here, two identical same-side modules normally do not form a link.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-29675325\">However, this should not be turned into a universal statement about every product called \u201cBiDi.\u201d Some advanced transceivers use multiple lanes, tunable wavelengths, automatic role selection or proprietary architectures.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1a536739\">The reliable field rule is:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-bb1e31cc\"><strong>For a fixed-wavelength single-fiber module, compare TX at one end with RX at the other in both directions.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5c419c7c\">Do not decide only from the words SFP, SFP+, BiDi, WDM, A, B, U or D.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-1723a21e\">A\/B and U\/D Labels Are Not Universal Definitions<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8bb9632d\">Suppliers may use:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Side A and Side B<\/li>\n\n\n\n<li><a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/ar\/tag\/bx-u\/\" title=\"View all posts in BX-U\">BX-U<\/a> \u0648 <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/ar\/tag\/bx-d\/\" title=\"View all posts in BX-D\">BX-D<\/a><\/li>\n\n\n\n<li>Upstream and downstream<\/li>\n\n\n\n<li>WDM-A and WDM-B<\/li>\n\n\n\n<li>Colored pull tabs or labels<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8e827ac1\">These names help identify a matched set, but they are not universal wavelength mappings.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5f0a9c05\">Cisco\u2019s 1G BX10-U\/D pair uses 1310nm and 1490nm, while its 10G BXU\/D pair uses 1270nm and 1330nm. A third-party 1.25G product may use 1310nm and 1550nm.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b913953b\">Never pair modules only because one says \u201cA\u201d and the other says \u201cB.\u201d Verify both TX\/RX wavelength lines, rate, reach and optical specifications.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-bfa270e1\">What Else Must Match Besides Wavelength?<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-8942f6b0\">1. Data application and actual line rate<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0d10e550\">Both modules and both hosts must operate in the same required mode. A complementary 1G module and 2.5G module do not create a working link merely because their wavelengths match.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9a193df4\">Physical SFP or SFP+ cage fit does not establish rate compatibility. Check the host SerDes mode, firmware, driver and port setting.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-d8584eb7\">2. Fiber type<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-86d9fead\">The LuLeey modules referenced here are specified for single-mode fiber. Do not substitute multimode fiber based only on connector fit.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-bf8933d8\">3. Connector type and polish<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ab0e97e9\">LC simplex and SC simplex are different physical interfaces. UPC and APC end faces must not be directly mated.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-95391b21\">4. Reach class and optical budget<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f31ce834\">Distance labels such as 10km, 20km and 40km describe an intended reach class, not a guarantee for every route.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c613697c\">\u062a\u062d\u0642\u0642 \u0645\u0646:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Minimum and maximum transmitter output<\/li>\n\n\n\n<li>Receiver sensitivity<\/li>\n\n\n\n<li>Receiver overload or maximum input<\/li>\n\n\n\n<li>Actual fiber, connector and splice loss<\/li>\n\n\n\n<li>Any required minimum attenuation<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-36579499\">Do not pair modules solely because both packages say \u201c20km.\u201d<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-0aee66cd\">5. Host recognition and coding<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2da27b37\">Some switches accept general coding; others warn about or reject unsupported transceivers. Verify the exact switch, router, NIC or media-converter model and firmware.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-345e8835\">6. Operating environment<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-dafa8e52\">Commercial and industrial modules may have different temperature ratings. Match the actual installation environment, not only the wavelength.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-1f8ea9f3\">How to Read a BiDi Module Label<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e80eb618\">Consider this example:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-64473b4f\"><strong>1.25G, TX1310nm\/RX1550nm, SMF, 20km, LC, DDM<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6e0cf6b0\">Read it as six separate checks:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>1.25G:<\/strong> intended application and host rate.<\/li>\n\n\n\n<li><strong>TX1310nm:<\/strong> wavelength leaving this module.<\/li>\n\n\n\n<li><strong>RX1550nm:<\/strong> wavelength this module expects.<\/li>\n\n\n\n<li><strong>SMF:<\/strong> single-mode fiber requirement.<\/li>\n\n\n\n<li><strong>20km:<\/strong> reach class under its specified budget.<\/li>\n\n\n\n<li><strong>LC and DDM:<\/strong> connector and diagnostic capability.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-66d640ac\">The opposite module should normally read TX1550nm\/RX1310nm while matching the other required conditions.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-43f480f8\">If the label shows only one wavelength, find the full datasheet. A single marketing wavelength may refer only to the transmitter.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-cebd1289\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22028\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-no-link-checklist.avif\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-no-link-checklist.avif 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-no-link-checklist-800x800.avif 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-no-link-checklist-400x400.avif 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-no-link-checklist-768x768.avif 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-no-link-checklist-12x12.avif 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-no-link-checklist-150x150.avif 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-1c2127ba\">BiDi SFP No-Link Troubleshooting<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-0ca37ed6\">Step 1: Record both exact part numbers<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-452de152\">Do not write only \u201ctwo 1G BiDi modules.\u201d Record both labels, host models, firmware and configured speeds.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-f92f383e\">Step 2: Build a two-direction wavelength table<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0627\u0644\u0627\u062a\u062c\u0627\u0647<\/th><th>Transmitter<\/th><th>Receiver<\/th><th>Match?<\/th><\/tr><\/thead><tbody><tr><td>Local to remote<\/td><td>Local TX<\/td><td>Remote RX<\/td><td>Yes\/No<\/td><\/tr><tr><td>Remote to local<\/td><td>\u0627\u0644\u0625\u0631\u0633\u0627\u0644 \u0639\u0646 \u0628\u064f\u0639\u062f<\/td><td>\u0648\u0635\u0641\u0629 \u0637\u0628\u064a\u0629 \u0645\u062d\u0644\u064a\u0629<\/td><td>Yes\/No<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1e7fc54e\">Both rows must match.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-e75ff5c2\">Step 3: Verify rate and host mode<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2bcf0b4a\">Check the configured and actual port speeds. Confirm that both hosts provide the mode required by the modules.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a5093b21\">For 2.5G modules, do not assume that an SFP+ cage provides 2.5G. The host chipset or PHY, firmware, driver and port configuration must support that SerDes mode.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-00649e45\">Step 4: Check the fiber path<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-aaf85c48\">Confirm that the cable is single-mode, reaches the intended endpoint and does not pass through an incompatible splitter, filter or PON network.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7345c35f\">A point-to-point Ethernet BiDi pair is not a substitute for a GPON or XGS-PON ONU and OLT pair.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-4fe1be19\">Step 5: Inspect and clean both connectors<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1d396218\">Use an inspect-clean-inspect process with tools matching LC or SC and the connector polish. Never look into an active fiber.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-d0ec4b65\">Step 6: Read DDM in the correct direction<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-78882a5c\">Compare the remote module\u2019s TX reading with the local module\u2019s RX reading. Repeat in the opposite direction.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a294ccdb\">An RX value reported as no signal or very low can support the diagnosis, but DDM accuracy depends on the module and host.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-83febded\">Step 7: Compare power with exact limits<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ed1f75a3\">If wavelengths and rates are correct, compare RX power with the receiver sensitivity and overload limits. Too little or too much light can prevent reliable operation.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-d8b18a27\">Step 8: Test a verified pair<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4135cb8e\">Use a known-good complementary pair with the correct coding and reach. Change one variable at a time and record the result.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-b599e1da\">Example with LuLeey BiDi SFP Modules<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a16cc2ad\">LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/ar\/product\/1-25g-bidi-sfp-module-gigabit-sc-smf-10km-ddm-transceiver-pair\/\">1.25G SC BiDi SFP pair for 10km<\/a> is listed as a matched 1310\/1550nm pair using one single-mode fiber, an SC simplex interface and DDM. Its page states that TX1310\/RX1550 must pair with TX1550\/RX1310.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-86fe1aad\">For a 2.5G host, LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/ar\/product\/2-5g-sc-smf-sfp-module-support-bidi\/\">2.5G SC BiDi SFP for 20km<\/a> is listed for a 1310\/1550nm complementary pair, SC simplex and single-mode fiber.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-401df3cf\">The 2.5G product page also states that the host must support 2.5G SFP operation. Do not order it for a fixed 1G port or assume every 10G SFP+ port supports native 2.5G.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a7ec2ce2\">Before ordering, provide:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Both host models and firmware<\/li>\n\n\n\n<li>Required data rate<\/li>\n\n\n\n<li>Local and remote coding requirements<\/li>\n\n\n\n<li>Fiber type and available core count<\/li>\n\n\n\n<li>Connector and polish at each end<\/li>\n\n\n\n<li>Route distance and estimated loss<\/li>\n\n\n\n<li>Required temperature range<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-2ee990fc\">\u0627\u0644\u0625\u062c\u0627\u0628\u0629 \u0627\u0644\u0646\u0647\u0627\u0626\u064a\u0629<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-690f3d1a\">Two identical fixed-wavelength BiDi SFP modules normally will not work together because their TX and RX wavelength directions are the same.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9a2b1213\">Use a complementary pair in which:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Local TX equals remote RX.<\/li>\n\n\n\n<li>Remote TX equals local RX.<\/li>\n\n\n\n<li>Both ends use the same application rate.<\/li>\n\n\n\n<li>Both hosts support the required SerDes mode and coding.<\/li>\n\n\n\n<li>Fiber, connector, reach and optical power are compatible.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9b37bfa1\">Matching the words \u201cBiDi\u201d and \u201c20km\u201d is not enough. The complete two-direction link must match.<\/p>","protected":false},"excerpt":{"rendered":"<p>Local module Remote module Wavelength result Expected outcome TX1310\/RX1550 TX1310\/RX1550 Both transmit 1310; both listen for 1550 No normal link<\/p>","protected":false},"author":1,"featured_media":22029,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[887],"tags":[1382,1386,1496,1495,1497,1494,1493,1492],"class_list":["post-22027","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-data-transmission-conversion","tag-optical-transceiver","tag-bidi-sfp","tag-bx-d","tag-bx-u","tag-fiber-link-troubleshooting","tag-sfp-wavelength","tag-single-fiber-sfp","tag-wdm-sfp-2"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/posts\/22027","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/comments?post=22027"}],"version-history":[{"count":0,"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/posts\/22027\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/media\/22029"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/media?parent=22027"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/categories?post=22027"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/tags?post=22027"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}