{"id":12665,"date":"2024-07-19T00:54:45","date_gmt":"2024-07-18T16:54:45","guid":{"rendered":"https:\/\/www.luleey.com\/?post_type=product&#038;p=12665"},"modified":"2026-10-03T23:56:56","modified_gmt":"2026-10-03T15:56:56","slug":"otdr-test-bare-fiber-coupler-fc-adapter-ll-bare-fiber-coupler","status":"publish","type":"product","link":"https:\/\/www.luleey.com\/ar\/product\/otdr-test-bare-fiber-coupler-fc-adapter-ll-bare-fiber-coupler\/","title":{"rendered":"\u0645\u062d\u0648\u0644 \u0627\u0644\u0623\u0644\u064a\u0627\u0641 \u0627\u0644\u0639\u0627\u0631\u064a\u0629 \u0645\u0646 \u0646\u0648\u0639 FC \u0644\u0623\u062c\u0647\u0632\u0629 OTDR \u0648\u0645\u0642\u064a\u0627\u0633 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0636\u0648\u0626\u064a\u0629"},"content":{"rendered":"<h2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"16vwcbe\" data-start=\"1632\" data-end=\"1665\">FC Bare Fiber Adapter Overview<\/h2>\n<p data-start=\"1667\" data-end=\"1843\">\u0627\u0644\u0640 <strong data-start=\"1671\" data-end=\"1696\">\u0645\u062d\u0648\u0644 \u0627\u0644\u0623\u0644\u064a\u0627\u0641 \u0627\u0644\u0639\u0627\u0631\u064a\u0629 \u0645\u0646 \u0646\u0648\u0639 FC<\/strong> is a reusable fiber testing accessory designed to provide a temporary connection between prepared bare optical fiber and an FC\/UPC test interface.<\/p>\n<p data-start=\"1845\" data-end=\"2202\">It allows technicians to connect bare fiber directly to an OTDR, optical power meter, optical light source, or compatible fiber test instrument without installing a permanent connector. The epoxy-free design makes the fiber easy to insert, remove, and test repeatedly during fiber inspection, troubleshooting, production testing, and laboratory measurement.<\/p>\n<p data-start=\"2204\" data-end=\"2431\">The adapter supports standard 125\u03bcm single mode and multimode fibers. Its ceramic alignment core helps maintain stable fiber positioning and low optical loss when the fiber is correctly stripped, cleaned, cleaved, and inserted.<\/p>\n<p data-start=\"2433\" data-end=\"2742\">With insertion loss of \u22640.2dB and a compact reusable structure, the adapter is suitable for field technicians, laboratories, fiber production facilities, and optical equipment maintenance. It provides a fast connection method for unterminated fiber without fusion splicing or permanent connector installation.<\/p>\n<p data-start=\"2433\" data-end=\"2742\">\n<h2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1ma7m6t\" data-start=\"2835\" data-end=\"2850\">\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n<ul data-start=\"2852\" data-end=\"3210\">\n<li data-section-id=\"1urkxlw\" data-start=\"2852\" data-end=\"2893\">FC\/UPC male to bare fiber configuration<\/li>\n<li data-section-id=\"1soein2\" data-start=\"2894\" data-end=\"2937\">Compatible with standard 125\u03bcm bare fiber<\/li>\n<li data-section-id=\"jjr116\" data-start=\"2938\" data-end=\"2982\">Supports single mode and multimode testing<\/li>\n<li data-section-id=\"wvjeni\" data-start=\"2983\" data-end=\"3010\">Low insertion loss \u22640.2dB<\/li>\n<li data-section-id=\"nit2ri\" data-start=\"3011\" data-end=\"3047\">Ceramic core for precise alignment<\/li>\n<li data-section-id=\"zoxtcr\" data-start=\"3048\" data-end=\"3067\">No epoxy required<\/li>\n<li data-section-id=\"137hr1i\" data-start=\"3068\" data-end=\"3102\">Easy fiber insertion and removal<\/li>\n<li data-section-id=\"1udt472\" data-start=\"3103\" data-end=\"3134\">Reusable temporary connection<\/li>\n<li data-section-id=\"1unfcno\" data-start=\"3135\" data-end=\"3166\">Compact handheld construction<\/li>\n<li data-section-id=\"keg8wu\" data-start=\"3167\" data-end=\"3210\">Suitable for field and laboratory testing<\/li>\n<\/ul>\n<h2 data-section-id=\"mu966k\" data-start=\"3212\" data-end=\"3227\">\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h2>\n<ul data-start=\"3229\" data-end=\"3516\">\n<li data-section-id=\"1eux7xv\" data-start=\"3229\" data-end=\"3243\">OTDR testing<\/li>\n<li data-section-id=\"oymzwx\" data-start=\"3244\" data-end=\"3271\">Optical power measurement<\/li>\n<li data-section-id=\"arlooh\" data-start=\"3272\" data-end=\"3302\">Optical light source testing<\/li>\n<li data-section-id=\"s79s7n\" data-start=\"3303\" data-end=\"3333\">Bare fiber continuity checks<\/li>\n<li data-section-id=\"1dq9mey\" data-start=\"3334\" data-end=\"3365\">Fiber attenuation measurement<\/li>\n<li data-section-id=\"7mgkkv\" data-start=\"3366\" data-end=\"3395\">Fiber production inspection<\/li>\n<li data-section-id=\"2dv3pu\" data-start=\"3396\" data-end=\"3425\">Telecom network maintenance<\/li>\n<li data-section-id=\"zfocuj\" data-start=\"3426\" data-end=\"3457\">FTTH and FTTX troubleshooting<\/li>\n<li data-section-id=\"1gxyhdd\" data-start=\"3458\" data-end=\"3486\">\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u0628\u0635\u0631\u064a\u0629 \u0627\u0644\u0645\u062e\u062a\u0628\u0631\u064a\u0629<\/li>\n<li data-section-id=\"8twcdo\" data-start=\"3487\" data-end=\"3516\">\u062a\u0648\u0635\u064a\u0644\u0627\u062a \u0627\u0644\u0623\u0644\u064a\u0627\u0641 \u0627\u0644\u0645\u0624\u0642\u062a\u0629<\/li>\n<\/ul>\n<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"vqosjl\" data-start=\"3628\" data-end=\"3656\">\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629<\/h1>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"3658\" data-end=\"4197\">\n<thead data-start=\"3658\" data-end=\"3687\">\n<tr data-start=\"3658\" data-end=\"3687\">\n<th class=\"last:pe-10\" data-start=\"3658\" data-end=\"3670\" data-col-size=\"sm\">\u0627\u0644\u0645\u0639\u0644\u0645\u0629<\/th>\n<th class=\"last:pe-10\" data-start=\"3670\" data-end=\"3687\" data-col-size=\"sm\">\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"3698\" data-end=\"4197\">\n<tr data-start=\"3698\" data-end=\"3716\">\n<td data-start=\"3698\" data-end=\"3706\" data-col-size=\"sm\">\u0627\u0644\u0639\u0644\u0627\u0645\u0629 \u0627\u0644\u062a\u062c\u0627\u0631\u064a\u0629<\/td>\n<td data-start=\"3706\" data-end=\"3716\" data-col-size=\"sm\">\u0644\u0648\u0644\u0648\u064a<\/td>\n<\/tr>\n<tr data-start=\"3717\" data-end=\"3759\">\n<td data-start=\"3717\" data-end=\"3732\" data-col-size=\"sm\">\u0646\u0648\u0639 \u0627\u0644\u0645\u0646\u062a\u062c<\/td>\n<td data-col-size=\"sm\" data-start=\"3732\" data-end=\"3759\">Bare Fiber Test Adapter<\/td>\n<\/tr>\n<tr data-start=\"3760\" data-end=\"3809\">\n<td data-start=\"3760\" data-end=\"3780\" data-col-size=\"sm\">\u0648\u0627\u062c\u0647\u0629 \u0627\u0644\u0645\u062d\u0648\u0644<\/td>\n<td data-col-size=\"sm\" data-start=\"3780\" data-end=\"3809\">FC\/UPC Male to Bare Fiber<\/td>\n<\/tr>\n<tr data-start=\"3810\" data-end=\"3842\">\n<td data-start=\"3810\" data-end=\"3827\" data-col-size=\"sm\">Connector Side<\/td>\n<td data-col-size=\"sm\" data-start=\"3827\" data-end=\"3842\">FC\/UPC \u0630\u0643\u0631<\/td>\n<\/tr>\n<tr data-start=\"3843\" data-end=\"3870\">\n<td data-start=\"3843\" data-end=\"3856\" data-col-size=\"sm\">Fiber Side<\/td>\n<td data-col-size=\"sm\" data-start=\"3856\" data-end=\"3870\">\u0627\u0644\u0623\u0644\u064a\u0627\u0641 \u0627\u0644\u0639\u0627\u0631\u064a\u0629<\/td>\n<\/tr>\n<tr data-start=\"3871\" data-end=\"3902\">\n<td data-start=\"3871\" data-end=\"3893\" data-col-size=\"sm\">\u0642\u0637\u0631 \u0627\u0644\u0623\u0644\u064a\u0627\u0641 \u0627\u0644\u0639\u0627\u0631\u064a\u0629<\/td>\n<td data-col-size=\"sm\" data-start=\"3893\" data-end=\"3902\">125 \u0645\u064a\u0643\u0631\u0648\u0645\u062a\u0631<\/td>\n<\/tr>\n<tr data-start=\"3903\" data-end=\"3953\">\n<td data-start=\"3903\" data-end=\"3926\" data-col-size=\"sm\">Supported Fiber Mode<\/td>\n<td data-col-size=\"sm\" data-start=\"3926\" data-end=\"3953\">Single Mode \/ Multimode<\/td>\n<\/tr>\n<tr data-start=\"3954\" data-end=\"3991\">\n<td data-start=\"3954\" data-end=\"3975\" data-col-size=\"sm\">\u0645\u0648\u0627\u062f \u0627\u0644\u0645\u062d\u0627\u0630\u0627\u0629<\/td>\n<td data-col-size=\"sm\" data-start=\"3975\" data-end=\"3991\">\u0642\u0644\u0628 \u062e\u0632\u0641\u064a<\/td>\n<\/tr>\n<tr data-start=\"3992\" data-end=\"4019\">\n<td data-start=\"3992\" data-end=\"4009\" data-col-size=\"sm\">\u062e\u0633\u0627\u0631\u0629 \u0627\u0644\u0625\u062f\u062e\u0627\u0644<\/td>\n<td data-col-size=\"sm\" data-start=\"4009\" data-end=\"4019\">\u22640.2 \u062f\u064a\u0633\u064a\u0628\u0644<\/td>\n<\/tr>\n<tr data-start=\"4020\" data-end=\"4062\">\n<td data-start=\"4020\" data-end=\"4044\" data-col-size=\"sm\">\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/td>\n<td data-col-size=\"sm\" data-start=\"4044\" data-end=\"4062\">\u0645\u0646 -40 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u0625\u0644\u0649 +85 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629<\/td>\n<\/tr>\n<tr data-start=\"4097\" data-end=\"4139\">\n<td data-start=\"4097\" data-end=\"4115\" data-col-size=\"sm\">\u0646\u0648\u0639 \u0627\u0644\u0627\u062a\u0635\u0627\u0644<\/td>\n<td data-col-size=\"sm\" data-start=\"4115\" data-end=\"4139\">Temporary \/ Reusable<\/td>\n<\/tr>\n<tr data-start=\"4140\" data-end=\"4163\">\n<td data-start=\"4140\" data-end=\"4157\" data-col-size=\"sm\">Epoxy Required<\/td>\n<td data-col-size=\"sm\" data-start=\"4157\" data-end=\"4163\">\u0644\u0627<\/td>\n<\/tr>\n<tr data-start=\"4164\" data-end=\"4197\">\n<td data-start=\"4164\" data-end=\"4191\" data-col-size=\"sm\">Fusion Splicing Required<\/td>\n<td data-col-size=\"sm\" data-start=\"4191\" data-end=\"4197\">\u0644\u0627<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1gzii63\" data-start=\"4344\" data-end=\"4358\">How to Use<\/h1>\n<ol data-start=\"4360\" data-end=\"4768\">\n<li data-section-id=\"pc7rly\" data-start=\"4360\" data-end=\"4431\">Strip the fiber coating to expose the required length of bare fiber.<\/li>\n<li data-section-id=\"1sme6bc\" data-start=\"4432\" data-end=\"4498\">Clean the exposed fiber with suitable fiber-cleaning materials.<\/li>\n<li data-section-id=\"1nqrkia\" data-start=\"4499\" data-end=\"4556\">Cleave the fiber to produce a clean and flat end face.<\/li>\n<li data-section-id=\"hu73q7\" data-start=\"4557\" data-end=\"4610\">Insert the prepared fiber gently into the adapter.<\/li>\n<li data-section-id=\"ynhfpd\" data-start=\"4611\" data-end=\"4667\">Connect the FC\/UPC side to compatible test equipment.<\/li>\n<li data-section-id=\"exolq0\" data-start=\"4668\" data-end=\"4727\">Complete the measurement and carefully remove the fiber.<\/li>\n<li data-section-id=\"xw6kyr\" data-start=\"4728\" data-end=\"4768\">Replace the protective cap after use.<\/li>\n<\/ol>\n<\/div>","protected":false},"excerpt":{"rendered":"<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"1074\" data-end=\"1225\">\u0627\u0644\u0644\u0648\u0644\u064a <strong data-start=\"1085\" data-end=\"1110\">\u0645\u062d\u0648\u0644 \u0627\u0644\u0623\u0644\u064a\u0627\u0641 \u0627\u0644\u0639\u0627\u0631\u064a\u0629 \u0645\u0646 \u0646\u0648\u0639 FC<\/strong> connects prepared 125\u03bcm bare fiber to FC\/UPC test equipment for OTDR, optical power meter, and laboratory testing.<\/p>\n<ul data-start=\"1227\" data-end=\"1552\">\n<li data-section-id=\"1ren4hu\" data-start=\"1227\" data-end=\"1265\">FC\/UPC male to bare fiber connection<\/li>\n<li data-section-id=\"vnga9y\" data-start=\"1266\" data-end=\"1302\">Supports standard 125\u03bcm bare fiber<\/li>\n<li data-section-id=\"1qj44s6\" data-start=\"1303\" data-end=\"1357\">Suitable for single mode and multimode fiber testing<\/li>\n<li data-section-id=\"wvjeni\" data-start=\"1358\" data-end=\"1385\">Low insertion loss \u22640.2dB<\/li>\n<li data-section-id=\"1xzi288\" data-start=\"1386\" data-end=\"1420\">Precision ceramic alignment core<\/li>\n<li data-section-id=\"u8qfnr\" data-start=\"1421\" data-end=\"1454\">Epoxy-free temporary connection<\/li>\n<li data-section-id=\"1mftmqq\" data-start=\"1455\" data-end=\"1490\">\u062a\u0635\u0645\u064a\u0645 \u0645\u062f\u0645\u062c \u0648\u0642\u0627\u0628\u0644 \u0644\u0625\u0639\u0627\u062f\u0629 \u0627\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645<\/li>\n<li data-section-id=\"c9ua0c\" data-start=\"1491\" data-end=\"1552\">Suitable for OTDRs, optical power meters, and light sources<\/li>\n<\/ul>","protected":false},"featured_media":12691,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[365],"product_tag":[1334,213,1340,1337,275,283,1336],"class_list":["post-12665","product","type-product","status-publish","has-post-thumbnail","product_cat-optical-adapters-and-flange-connectors-and-attenuator","product_tag-bare-fiber-adapter","product_tag-fc","product_tag-fc-fiber-adapter","product_tag-fiber-test-tool","product_tag-optical-adapter","product_tag-otdr","product_tag-otdr-test-adapter","first","instock","shipping-taxable","purchasable","product-type-variable","has-default-attributes"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/product\/12665","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/comments?post=12665"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/media\/12691"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/media?parent=12665"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/product_brand?post=12665"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/product_cat?post=12665"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/ar\/wp-json\/wp\/v2\/product_tag?post=12665"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}