{"id":22311,"date":"2026-09-21T11:16:16","date_gmt":"2026-09-21T03:16:16","guid":{"rendered":"https:\/\/www.luleey.com\/?p=22311"},"modified":"2026-09-20T11:20:47","modified_gmt":"2026-09-20T03:20:47","slug":"how-to-test-an-sfp-port-with-a-fiber-loopback","status":"publish","type":"post","link":"https:\/\/www.luleey.com\/de\/how-to-test-an-sfp-port-with-a-fiber-loopback\/","title":{"rendered":"So testen Sie einen SFP-Anschluss mit einem Glasfaser-Loopback"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-9d78ff3e\">An <strong>testen und <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/de\/tag\/sfp\/\" title=\"Alle Beitr\u00e4ge in SFP anzeigen\">SFP<\/a> Hafen mit einem <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/de\/tag\/fiber-loopback\/\" title=\"Alle Beitr\u00e4ge zu \u201eFiber Loopback\u201c anzeigen\">Glasfaser-Loopback<\/a><\/strong>, verbinden Sie den optischen Sender \u00fcber einen korrekt angepassten passiven Glasfaserpfad wieder mit dem Empf\u00e4nger. Das Ergebnis kann dabei helfen, den lokalen Host-Port, den Transceiver und den Steckverbinderpfad von der entfernten Glasfaserinfrastruktur und dem Gegenst\u00fcckger\u00e4t zu isolieren.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-acbb8b30\">Es handelt sich um eine begrenzte Diagnose und nicht um eine vollst\u00e4ndige Zertifizierung der Verbindung. Ein Loopback, der den LOS-Status aufhebt oder die Schnittstelle in Betrieb nimmt, ist kein Nachweis f\u00fcr die Funktionsf\u00e4higkeit des Fernkabels, des Gegenst\u00fccks, der VLAN-Konfiguration oder der Interoperabilit\u00e4t im Produktivbetrieb. Bevor Sie irgendetwas anschlie\u00dfen, vergewissern Sie sich au\u00dferdem, dass die zur\u00fcckgesendete optische Leistung die maximale Eingangsleistung des Empf\u00e4ngers nicht \u00fcberschreiten darf.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-c6fd394d\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22313\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/test-sfp-port-fiber-loopback-hero.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/test-sfp-port-fiber-loopback-hero.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/test-sfp-port-fiber-loopback-hero-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/test-sfp-port-fiber-loopback-hero-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/test-sfp-port-fiber-loopback-hero-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/test-sfp-port-fiber-loopback-hero-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/test-sfp-port-fiber-loopback-hero-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-dede1808\">Einen SFP-Anschluss mit einem Glasfaser-Loopback testen: Was dabei zu beachten ist<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-012700e3\">Ein optischer Duplex-Transceiver verf\u00fcgt \u00fcber eine Sendeseite und eine Empfangsseite. Ein passiver Duplex-Loopback leitet Folgendes weiter:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e60db6ed\"><strong>Lokaler Sender (TX) \u2192 kurzer Glasfaserweg \u2192 lokaler Empf\u00e4nger (RX)<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6844dc07\">Je nach Host, PHY, Ethernet-PMD und Portkonfiguration kann das Ger\u00e4t den RX-LOS-Status zur\u00fccksetzen, eine Empf\u00e4ngerverriegelung melden oder den Status \u201eLink Up\u201c anzeigen. Einige Plattformen ben\u00f6tigen einen speziellen Diagnosemodus oder einen zweiten Port, sodass der Status \u201eLink Up\u201c nicht f\u00fcr jede g\u00fcltige lokale optische Schleife garantiert ist.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f287cb85\">Der Test kann diese lokalen Elemente unter den folgenden Testbedingungen pr\u00fcfen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Die F\u00e4higkeit des Hosts, das Modul zu erkennen und mit Strom zu versorgen<\/li>\n\n\n\n<li>Der optische Sender und Empf\u00e4nger des Moduls<\/li>\n\n\n\n<li>Der Loopback-Anschluss und der kurze Glasfaserweg<\/li>\n\n\n\n<li>Der elektrische\/SerDes-Pfad des Hosts reicht aus, um den beobachteten Status zu erzeugen<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8f53a1d3\">Das stimmt <strong>nicht<\/strong> den Produktionsstamm, Patchfelder, Splei\u00dfstellen, Remote-Transceiver oder Remote-Host zu testen. Au\u00dferdem generiert oder \u00fcberpr\u00fcft es nicht automatisch n\u00fctzlichen Ethernet-Datenverkehr. Ein Switch sendet m\u00f6glicherweise keinen Frame \u00fcber einen Port hinaus und nimmt denselben Frame nicht als R\u00fcckmeldung entgegen, wie dies bei einem normalen End-to-End-Test der Fall ist. F\u00fcr Pakettests sind eine von der Plattform unterst\u00fctzte Diagnosefunktion, ein Datenverkehrgenerator oder eine dokumentierte Testmethode erforderlich.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-6719bf2a\">1. Passen Sie den Loopback genau an die optische Schnittstelle an<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5e634b87\">Beginnen Sie mit der Artikelnummer des Transceivers und dessen Datenblatt. Passen Sie den Stecker, die Polierung und den Fasertyp des Loopbacks an das optische PMD an \u2013 nicht nur an das Metallmodulformat.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e7724fdb\">Beispielsweise wird bei einem typischen Duplex-10GBASE-SR-Modul Multimode-Glasfaser verwendet, w\u00e4hrend bei einem typischen Duplex-10GBASE-LR-Modul Singlemode-Glasfaser zum Einsatz kommt. IEEE 802.3 definiert unterschiedliche Spezifikationen f\u00fcr physikalische Medien f\u00fcr verschiedene Ethernet-\u00dcbertragungsraten und -Medien; die <a href=\"https:\/\/ieeexplore.ieee.org\/document\/9844436\" target=\"_blank\" rel=\"noopener\">IEEE 802.3-2022-Eintrag<\/a> Das ist zwar die Referenz f\u00fcr die Standards, aber letztendlich legen die jeweiligen Host- und Modul-Dokumente fest, was Ihre Hardware unterst\u00fctzt.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2060bef8\">Kreuzen Sie alle folgenden Punkte an:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Host-Modell, Portnummer und unterst\u00fctzte elektrische\/SerDes-Modi<\/li>\n\n\n\n<li>Modul-Teilenummer, Revisionsnummer, Codierung und optisches PMD<\/li>\n\n\n\n<li>Tats\u00e4chlich konfigurierte oder ausgehandelte Rate<\/li>\n\n\n\n<li>Fasertyp, Stecker und Polierung<\/li>\n\n\n\n<li>Alle erforderlichen FEC-, Auto-Negotiation- oder Port-Modus-Einstellungen<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-230dcae2\">Ein SFP, <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/de\/tag\/sfp-2\/\" title=\"Alle Nachrichten in SFP+ anzeigen\">SFP+<\/a> Auch die Bezeichnung \u201eSFP28\u201c kl\u00e4rt diese Fragen nicht. Die physikalische Kompatibilit\u00e4t, die Unterst\u00fctzung durch den Host, der Betriebsmodus, die Verbindungsgeschwindigkeit und die nutzbare Daten\u00fcbertragungsleistung sind voneinander unabh\u00e4ngige Faktoren.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-4a230470\">Verwenden Sie f\u00fcr einen BiDi-Test keinen normalen passiven Loopback.<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6cb08dd8\">Ein g\u00e4ngiges BiDi-Paar mit einer einzigen Faser nutzt komplement\u00e4re Sende- und Empfangswellenl\u00e4ngen. Ein Modul kann bei einer bestimmten Wellenl\u00e4nge senden, w\u00e4hrend es am Empf\u00e4nger eine andere Wellenl\u00e4nge erwartet. Eine passive Faserschleife leitet lediglich die gesendete Wellenl\u00e4nge zur\u00fcck; sie wandelt sie nicht um.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-77800a71\">Daher kann es vorkommen, dass keine Verbindung hergestellt wird, selbst wenn das BiDi-Modul einwandfrei funktioniert. Verwenden Sie daher ein korrekt abgestimmtes Gegenst\u00fcck oder einen wellenl\u00e4ngenabh\u00e4ngigen Testaufbau.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-f6ecaf2a\">2. \u00dcberpr\u00fcfen Sie die Stromversorgung des Empf\u00e4ngers, bevor Sie eine kurze Schleife bilden.<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d841db02\">Dies ist die wichtigste Sicherheits\u00fcberpr\u00fcfung bei Optiken mit gro\u00dfer Reichweite. Eine Produktionsstrecke kann mehrere Kilometer Glasfaser und einen Verlust von mehreren Dezibel umfassen. Eine kurze R\u00fcckkopplung beseitigt den gr\u00f6\u00dften Teil dieses Verlusts und kann zu viel Leistung zum Empf\u00e4nger zur\u00fcckleiten.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8fc4c68c\">Verwenden Sie das genaue Datenblatt des Moduls und berechnen Sie den voraussichtlich st\u00e4rksten Empfangspegel:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6cd63786\"><strong>maximale Sendeleistung \u2013 minimaler Verlust im R\u00fcckkopplungspfad = maximal zu erwartende Empfangsleistung<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b78ca695\">Das Ergebnis darf den Wert des Empf\u00e4ngers nicht \u00fcberschreiten. <strong>maximale Betriebsleistung<\/strong> f\u00fcr diesen Modus. Ber\u00fccksichtigen Sie dabei die Toleranzen aller Steckverbinder, Loopbacks und D\u00e4mpfungsglieder. Ersetzen Sie den maximalen Betriebs-Eingangswert nicht durch eine Schadensschwelle; diese beiden Gr\u00f6\u00dfen beantworten unterschiedliche Fragen.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-aeaf3289\">Falls im Datenblatt der maximale Empf\u00e4ngerwert nicht angegeben ist, halten Sie inne und fragen Sie nach. Falls eine D\u00e4mpfung erforderlich ist, verwenden Sie eine korrekt spezifizierte ged\u00e4mpfte R\u00fcckkopplungsleitung oder einen optischen D\u00e4mpfer. Vermeiden Sie Verluste, indem Sie ein Patchkabel nicht zu stark biegen.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6e7f7bc1\">Nach dem Anschlie\u00dfen, <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/de\/tag\/ddm\/\" title=\"Alle Beitr\u00e4ge in DDM anzeigen\">DDM<\/a> kann eine n\u00fctzliche Gegenpr\u00fcfung bieten, wenn sowohl das Modul als auch der Host diese Schnittstelle bereitstellen. <a href=\"https:\/\/members.snia.org\/document\/dl\/25916\" target=\"_blank\" rel=\"noopener\">SFF-8472<\/a> definiert Felder f\u00fcr Temperatur, Versorgungsspannung, TX-Vorspannung, TX-Leistung und RX-Leistung und unterscheidet zwischen der durchschnittlichen Empfangsleistung und den OMA-Meldungen. Die Genauigkeit und die Schwellenwerte des DDM h\u00e4ngen weiterhin vom jeweiligen Modul ab; vergleichen Sie den Messwert mit den genauen Betriebsgrenzen.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9bb9f6bb\">LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/de\/what-is-ddm-dom-in-sfp-transceivers\/\">DDM\/DOM-Feldf\u00fchrer<\/a> erl\u00e4utert die f\u00fcnf gemeinsamen Werte, w\u00e4hrend der <a href=\"https:\/\/www.luleey.com\/de\/sfp-receiver-overload-can-optical-power-be-too-high\/\">Leitfaden zur \u00dcberlastung des Empf\u00e4ngers<\/a> behandelt die Obergrenzenpr\u00fcfung ausf\u00fchrlicher.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-42ecff89\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22312\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/safe-sfp-loopback-test-flow.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/safe-sfp-loopback-test-flow.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/safe-sfp-loopback-test-flow-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/safe-sfp-loopback-test-flow-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/safe-sfp-loopback-test-flow-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/safe-sfp-loopback-test-flow-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/safe-sfp-loopback-test-flow-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-d72e2a62\">3. F\u00fchren Sie den lokalen Loopback-Test durch<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d2565199\">Nutzen Sie ein genehmigtes Wartungsfenster. Das Trennen eines Produktionspfads f\u00fchrt zu einer Unterbrechung des Betriebs.<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Erfassen Sie den Ausgangswert.<\/strong> Speichern Sie das Host-Modell, die Portkonfiguration, die Modul-ID, die Firmware\/den Treiber, den aktuellen Link-\/LOS-Status, die DDM-Messwerte und die Fehlerz\u00e4hler.<\/li>\n\n\n\n<li><strong>\u00dcberpr\u00fcfen Sie die geplante Kombination.<\/strong> \u00dcberpr\u00fcfen Sie PMD, Leistung, Faserkategorie, Stecker\/Polierqualit\u00e4t und den sicheren Empfangspegel. Verlassen Sie sich nicht allein auf den Sitz des Steckers.<\/li>\n\n\n\n<li><strong>\u00dcberpr\u00fcfen und reinigen.<\/strong> \u00dcberpr\u00fcfen Sie die Loopback- und Transceiver-Schnittstelle mit zugelassenen Ger\u00e4ten und reinigen Sie sie bei Bedarf. Die <a href=\"https:\/\/foa.org\/tech\/ref\/testing\/test\/scope.html\" target=\"_blank\" rel=\"noopener\">Leitfaden zu Steckverbindern der Fiber Optic Association<\/a> erl\u00e4utert, wie Verunreinigungen zwischen zusammengef\u00fcgten Ferrulen \u00fcbertragen werden k\u00f6nnen. Schauen Sie niemals direkt in eine Faser oder einen optischen Anschluss; verwenden Sie stattdessen ein geeignetes Leistungsmessger\u00e4t und ein Videoinspektionsverfahren.<\/li>\n\n\n\n<li><strong>F\u00fcgen Sie den richtigen Loopback ein.<\/strong> Verbinden Sie den lokalen TX-Anschluss mit dem lokalen RX-Anschluss, ohne den Stecker zu \u00fcberdehnen oder zu verdrehen. Aktivieren Sie den vorgesehenen Portmodus gem\u00e4\u00df der Anleitung des Hosts.<\/li>\n\n\n\n<li><strong>Beobachten Sie den Status und die \u00c4nderungen.<\/strong> \u00dcberpr\u00fcfen Sie das Vorhandensein des Moduls, TX-Fehler, RX-LOS, den Link-\/PCS-Status, die DDM-Empfangsleistung, Link-Ereignisse und \u00c4nderungen des Fehlerz\u00e4hlers. Zeichnen Sie einen zeitgesteuerten Vorher-Nachher-Vergleich auf.<\/li>\n\n\n\n<li><strong>Verwenden Sie \u201eTraffic\u201c nur, wenn dies unterst\u00fctzt wird.<\/strong> Falls die Plattform eine dokumentierte Portdiagnose oder einen Datentr\u00e4gertest anbietet, befolgen Sie genau diese Vorgehensweise. Gehen Sie nicht davon aus, dass ein Ping an das Ger\u00e4t selbst den physischen Port durchl\u00e4uft.<\/li>\n\n\n\n<li><strong>Entfernen und wiederherstellen.<\/strong> Deaktivieren oder isolieren Sie den Port nach Bedarf, entfernen Sie den Loopback, sichern und bereinigen Sie die Schnittstellen, stellen Sie die genehmigte Konfiguration wieder her und \u00fcberpr\u00fcfen Sie, ob der normale Betrieb wiederhergestellt ist.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-f16ced4b\">4. Das Ergebnis interpretieren, ohne zu weit zu gehen<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Beobachtung<\/th><th>Was es unterst\u00fctzt<\/th><th>N\u00fctzliche n\u00e4chste \u00dcberpr\u00fcfung<\/th><\/tr><\/thead><tbody><tr><td>Modul wird nicht erkannt<\/td><td>Der Host kann das Modul in der aktuellen Konfiguration weder lesen noch akzeptieren.<\/td><td>Pr\u00fcfen Sie den K\u00e4fig, die Stromversorgung, die Codierung, die Liste der unterst\u00fctzten Module, die Firmware und den Portmodus<\/td><\/tr><tr><td>Das Modul wurde erkannt, aber \u201eRX LOS\u201c bleibt aktiviert<\/td><td>Der lokale Empf\u00e4nger empf\u00e4ngt kein akzeptables Signal.<\/td><td>\u00dcberpr\u00fcfung der TX-Freigabe\/Fehler, der Glasfaser- und Polierpassung, des Loopback-Anschlusses, des Wellenl\u00e4ngenverhaltens und der optischen Leistung<\/td><\/tr><tr><td>LOS wird gel\u00f6scht oder die Verbindung wird mit stabilen Z\u00e4hlern hergestellt<\/td><td>Der getestete lokale Lichtweg funktioniert unter diesen Bedingungen<\/td><td>Weiter zum Produktions-Patchkabel, zu den Schalttafeln, zum Trunk und zum Remote-Peer<\/td><\/tr><tr><td>Die Verbindung wird hergestellt, aber es treten vermehrt Fehler auf<\/td><td>Das Vorhandensein eines Signals bedeutet nicht, dass die Bilder fehlerfrei \u00fcbertragen werden<\/td><td>\u00dcberpr\u00fcfen Sie die Leistungsgrenzwerte, die Verschmutzung sowie die PMD-, Raten- und FEC-Einstellungen und den lokalen Modul-\/Host-Pfad.<\/td><\/tr><tr><td>Ein BiDi-Modul verweist nicht auf sich selbst.<\/td><td>Das kann normal sein, da sich die Wellenl\u00e4ngen von TX und RX unterscheiden.<\/td><td>Verwenden Sie den komplement\u00e4ren BiDi-Peer oder eine wellenl\u00e4ngenabh\u00e4ngige Konfiguration<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a56bc152\">Ein erfolgreicher Loop-Test schr\u00e4nkt den Fehlerbereich ein. Er liefert jedoch keine Gew\u00e4hr f\u00fcr die Temperaturreserve, das Langzeitfehlerverhalten oder die Kompatibilit\u00e4t mit dem Remote-Ger\u00e4t. Umgekehrt ist ein fehlgeschlagener Loop-Test kein unmittelbarer Beweis f\u00fcr ein defektes Modul: Auch der Testaufbau, das Verhalten des Hosts, die Portkonfiguration oder eine zu hohe bzw. zu geringe optische Leistung k\u00f6nnen daf\u00fcr verantwortlich sein.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-da0975f5\">Wenn die Schnittstelle zwar verbunden ist, aber Fehler auftreten, fahren Sie mit LuLeey\u2019s fort <a href=\"https:\/\/www.luleey.com\/de\/sfp-crc-errors-with-normal-rx-power-what-to-check\/\">Leitfaden zur Fehlerbehebung bei SFP-CRC<\/a> und vergleichen Sie die aktuellen Differenzen an der Theke statt einer historischen Gesamtsumme.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-bb1f8201\">Die Wahl eines LuLeey Loopback<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2eacb4f2\">LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/de\/produkt-2\/fiber-optic-loopback-lc-upc-om3-mm\/\">LC\/UPC OM3-Multimode-Glasfaser-Loopback<\/a> ist als 50\/125-\u00b5m-Multimode-Kabel mit einer LC\/UPC-Schnittstelle und einer Einf\u00fcgungsd\u00e4mpfung von h\u00f6chstens 0,2 dB angegeben. Diese Eigenschaften machen es jedoch nicht zu einem universellen Kabel.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7c2bc1e9\">Der ver\u00f6ffentlichte Wert ist ein <strong>maximale Einf\u00fcgungsd\u00e4mpfung<\/strong>, und keine garantierte Mindestd\u00e4mpfung. Dies allein reicht nicht aus, um nachzuweisen, dass eine kurze Schleife f\u00fcr ein unbekanntes Sender-Empf\u00e4nger-Paar sicher ist. Auf der Seite wird zudem eine allgemeine Formulierung hinsichtlich der \u00dcbertragungsrate verwendet; w\u00e4hlen Sie die Loopback-Schleife anhand der genauen PMD, der Lane-Anordnung, der Modulgrenzwerte und des Host-Verhaltens aus, anstatt sich allein auf den Namen einer SFP-Familie oder die Nennrate zu st\u00fctzen.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-14893bfa\"><strong>N\u00e4chster Schritt:<\/strong> Senden Sie LuLeey das Host-Modell und den Port, die Modul-Teilenummer\/Revision, den optischen PMD-Wert, den Glasfaser-\/Steckertyp, die konfigurierte \u00dcbertragungsrate, die Firmware sowie die TX\/RX-Betriebsgrenzen des Moduls. LuLeey kann dann den geeigneten Loopback-Typ best\u00e4tigen und feststellen, ob eine kontrollierte D\u00e4mpfung erforderlich ist.<\/p>","protected":false},"excerpt":{"rendered":"<p>Beobachtung Was wird unterst\u00fctzt? N\u00fctzliche n\u00e4chste \u00dcberpr\u00fcfung Modul wird nicht erkannt Der Host kann das Modul nicht lesen oder akzeptieren in<\/p>","protected":false},"author":1,"featured_media":22313,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1078],"tags":[69,444,1668,1670,1642,1669,71],"class_list":["post-22311","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-user-operation-guide","tag-sfp","tag-ddm","tag-fiber-loopback","tag-lc-loopback","tag-network-maintenance","tag-optical-troubleshooting","tag-sfp-2"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/posts\/22311","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/comments?post=22311"}],"version-history":[{"count":1,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/posts\/22311\/revisions"}],"predecessor-version":[{"id":22314,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/posts\/22311\/revisions\/22314"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/media\/22313"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/media?parent=22311"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/categories?post=22311"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/tags?post=22311"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}