{"id":22361,"date":"2026-09-24T12:37:44","date_gmt":"2026-09-24T04:37:44","guid":{"rendered":"https:\/\/www.luleey.com\/?p=22361"},"modified":"2026-09-23T12:59:19","modified_gmt":"2026-09-23T04:59:19","slug":"sfp-rx-los-vs-tx-fault-what-each-alarm-means","status":"publish","type":"post","link":"https:\/\/www.luleey.com\/de\/sfp-rx-los-vs-tx-fault-what-each-alarm-means\/","title":{"rendered":"SFP RX LOS vs. TX Fault: Was die einzelnen Alarme bedeuten"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-9ece3cbf\"><strong><a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/de\/tag\/sfp\/\" title=\"Alle Beitr\u00e4ge in SFP anzeigen\">SFP<\/a> <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/de\/tag\/rx-los\/\" title=\"Alle Beitr\u00e4ge in \u201eRX LOS\u201c anzeigen\">RX LOS<\/a> vs <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/de\/tag\/tx-fault\/\" title=\"Alle Beitr\u00e4ge zu \u201eTX Fault\u201c anzeigen\">TX-Fehler<\/a><\/strong> Es handelt sich um eine Frage zur gezielten Fehlersuche und nicht um zwei Bezeichnungen f\u00fcr denselben Fehler. \u201eRX LOS\u201c bedeutet, dass das lokale Modul einen Signalverlust beim Empfang meldet. \u201eTX Fault\u201c bedeutet, dass das lokale Modul ein Problem auf der Senderseite meldet.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-90a88710\">Keiner der beiden Status allein beweist, dass der gesamte Transceiver defekt ist. Beginnen Sie mit dem Ende, das den Status meldet, ermitteln Sie die betroffene Richtung und testen Sie dann jeweils einen Teil dieser Richtung.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2aafb900\">Dieser Leitfaden behandelt g\u00e4ngige optische Ethernet-SFP-Module f\u00fcr Punkt-zu-Punkt-Verbindungen und <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/de\/tag\/sfp-2\/\" title=\"Alle Nachrichten in SFP+ anzeigen\">SFP+<\/a> Links. Die genauen Bezeichnungen, die Polarit\u00e4t und die Statusanzeige k\u00f6nnen je nach Modul und Host variieren. Beziehen Sie sich daher auf die Handb\u00fccher der jeweiligen Hardware.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-36b3e9d8\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22362\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-847767e5\">SFP RX LOS vs. TX-Fehler: Der Unterschied in einer Minute<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3546919a\">Nehmen wir eine einfache Duplex-Verbindung zwischen Ger\u00e4t A und Ger\u00e4t B an.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>An Ger\u00e4t B angezeigter Status<\/th><th>Was das Modul meldet<\/th><th>Erster zu untersuchender Ansatz<\/th><th>Was es nicht beweist<\/th><\/tr><\/thead><tbody><tr><td>RX LOS aktiviert<\/td><td>Der Empf\u00e4nger von B erkennt kein akzeptables Eingangssignal.<\/td><td>Ein Sender \u2192 Glasfaserstrecke von A nach B \u2192 Empf\u00e4nger B<\/td><td>Der Empf\u00e4nger von B ist definitiv defekt.<\/td><\/tr><tr><td>TX-Fehler ausgel\u00f6st<\/td><td>Das Modul von B meldet einen lokalen Senderfehler<\/td><td>B-Host-Stromversorgung\/Steuerung \u2192 B-Modul-Sender<\/td><td>Die B-zu-A-Faser ist unterbrochen.<\/td><\/tr><tr><td>Beide behaupteten<\/td><td>B weist einen lokalen TX-Fehler auf und empf\u00e4ngt zudem kein akzeptables Signal.<\/td><td>Behandeln Sie die Richtungen separat und \u00fcberpr\u00fcfen Sie anschlie\u00dfend die gemeinsame Leistung, die Konfiguration und den Modulstatus.<\/td><td>Ein einziger Faserriss erkl\u00e4rt alle Symptome<\/td><\/tr><tr><td>Beides wurde nicht behauptet, aber der Link funktioniert nicht<\/td><td>Diese beiden Statussignale geben keinen Aufschluss \u00fcber die Ursache.<\/td><td>PMD, \u00dcbertragungsrate, FEC, Host-Modus, Codierung, Polarit\u00e4t und Peer-Status<\/td><td>Die physikalische und elektrische Konfiguration ist kompatibel<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6095e855\">Der aktuelle <a href=\"https:\/\/members.snia.org\/document\/dl\/25880\" target=\"_blank\" rel=\"noopener\">SNIA-Spezifikation SFF-8419<\/a> Karten <code>Tx_Fault<\/code> als Ausgang \u201eSenderfehler\u201c des Moduls und <code>Rx_LOS<\/code> als Anzeige f\u00fcr einen Signalverlust auf der Empf\u00e4ngerseite. Bei Ethernet kann das Empfangssignal auch dargestellt werden als <strong>Signalerfassung<\/strong>. Ein Moderator kann daher denselben Sachverhalt sowohl positiv als auch negativ formulieren, zum Beispiel <code>RX LOS: Ja<\/code> oder <code>Signalerkennung: Nein<\/code>.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3f341e3c\">Interpretieren Sie einen unbekannten <code>RX-Fehler<\/code> Bezeichnung, bis im Handbuch der Plattform angegeben ist, ob damit \u201eRX LOS\u201c, geringe Empfangsleistung, ein PCS-Fehler oder ein anderer Gesamtzustand gemeint ist.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-faabc045\">RX LOS zeigt zur\u00fcck in die Ankunftsrichtung<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-258b847d\">Wenn Ger\u00e4t B \u201eRX LOS\u201c signalisiert, beginne mit der optischen Richtung, aus der das Signal in B eintreten sollte:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8332752b\"><strong>A TX \u2192 A-Stecker \u2192 Glasfaserleitung \u2192 B-Stecker \u2192 B RX<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-96271753\">M\u00f6gliche Ursachen sind unter anderem ein deaktivierter oder ausgefallener Sender an A, vertauschte Duplex-Polarit\u00e4t, ein getrennter oder verschmutzter Stecker, \u00fcberm\u00e4\u00dfige Wegd\u00e4mpfung, der falsche Fasertyp, inkompatible Wellenl\u00e4ngen oder PMDs, ein falsches BiDi-A\/B-Paar oder ein Problem am Empf\u00e4nger von B. \u201eRX LOS\u201c grenzt die Richtung ein; es wird jedoch keine einzelne defekte Komponente identifiziert.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1b834363\">\u00dcberpr\u00fcfen Sie die entgegengesetzte Richtung separat. Es kann vorkommen, dass B keine Daten von A empf\u00e4ngt, w\u00e4hrend A weiterhin wie gewohnt Daten von B empf\u00e4ngt. Ein einzelnes Symbol f\u00fcr \u201eVerbindung unterbrochen\u201c verdeckt oft diesen Richtungsunterschied.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-36b41886\">Bei einer Duplex-Verbindung ist sicherzustellen, dass jeder Sender den gegen\u00fcberliegenden Empf\u00e4nger erreicht. Bei BiDi-Verbindungen mit einer einzigen Faser sind komplement\u00e4re Sende- und Empfangswellenl\u00e4ngen zu \u00fcberpr\u00fcfen; zwei Module, die in dieselbe Richtung senden, bilden kein normales Paar.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-773f86cd\">Der TX-Fehler liegt auf der Senderseite<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b18959a0\">Wenn Ger\u00e4t B einen TX-Fehler meldet, konzentrieren Sie sich zun\u00e4chst auf das Modul von B und darauf, wie dessen Host den Sender mit Strom versorgt und steuert. Pr\u00fcfen Sie, ob der Host absichtlich \u201eTX Disable\u201c gesetzt hat, ob die Diagnosedaten nach der Initialisierung g\u00fcltig sind und ob Spannung, Temperatur oder eine andere Senderwarnung f\u00fcr genau dieses Modul auff\u00e4llig ist.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-de56146d\">\u201eTX Disable\u201c und \u201eTX Fault\u201c sind unterschiedliche Signale. \u201eTX Disable\u201c ist ein Steuerungssignal vom Host zum Modul, das den Sender ausschaltet. \u201eTX Fault\u201c ist ein Statussignal vom Modul zum Host. Ein deaktivierter Sender kann dazu f\u00fchren, dass die Gegenstelle \u201eRX LOS\u201c meldet, ohne dass damit ein Ausfall des Senders nachgewiesen wird.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a94df145\">Sofern DDM verf\u00fcgbar ist, vergleichen Sie den TX-Fehler mit der Temperatur, der Versorgungsspannung, der TX-Vorspannung und der TX-Ausgangsleistung zum selben Zeitstempel. LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/de\/sfp-tx-bias-current-high-causes-and-fixes\/\">Leitfaden zum SFP-TX-Vorspannungsstrom<\/a> erkl\u00e4rt, warum eine Bias-Warnung, eine abnehmende Sendeleistung und ein Sendefehler zusammen aussagekr\u00e4ftiger sind als ein einzelner Wert.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d768143c\">Setzen Sie ein Produktionsmodul nicht wiederholt zur\u00fcck und schlie\u00dfen Sie es nicht im laufenden Betrieb an, nur um die Markierung zu l\u00f6schen. Befolgen Sie die f\u00fcr den Host und das Modul geltenden Verfahren, bewahren Sie die urspr\u00fcnglichen Nachweise auf und nutzen Sie ein genehmigtes Wartungsfenster.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-b479039e\">\u201eRX LOS\u201c ist nicht dasselbe wie ein RX-Leistungsalarm<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1c6fdc12\"><a href=\"https:\/\/members.snia.org\/document\/dl\/25916\" target=\"_blank\" rel=\"noopener\">SFF-8472 Rev. 12.5a<\/a> definiert die Zust\u00e4nde \u201eDigital TX Fault\u201c und \u201eRX LOS\u201c getrennt von optionalen Alarm- und Warnflags f\u00fcr Temperatur, Spannung, TX-Vorspannung, TX-Leistung und empfangene optische Leistung. Au\u00dferdem ist die Soft-\u00dcberwachung optional.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-16f56dd5\">Diese Unterscheidung ist wichtig:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><code>RX LOS<\/code> ist eine Signalanzeige.<\/li>\n\n\n\n<li><code>Warnung: Niedrige RX-Leistung<\/code> vergleicht einen \u00fcberwachten Wert mit einem voreingestellten Warnschwellenwert.<\/li>\n\n\n\n<li><code>Alarm \u201eNiedrige Leistung\u201c<\/code> ist ein Hinweis auf ein schwerwiegenderes Problem.<\/li>\n\n\n\n<li>Ein angezeigter dBm-Wert ist ein erfasster Diagnosewert, dessen Genauigkeit und Darstellungsweise modulspezifisch sind.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d7abb9a3\">Die Schwellenwerte und das Verhalten m\u00fcssen nicht identisch sein. Ein Modul kann eine gewisse Empfangsleistung melden, ohne dennoch ein akzeptables Signal f\u00fcr die ausgew\u00e4hlte PMD und Rate zu erkennen. Umgekehrt kann es vorkommen, dass ein Host keinen \u201eSoft RX LOS\u201c-Zustand meldet, selbst wenn er den physikalischen Status-Pin intern nutzt.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-91948d7c\">Nutze LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/de\/what-is-ddm-dom-in-sfp-transceivers\/\">DDM\/DOM-Feldf\u00fchrer<\/a> um einen vollst\u00e4ndigen \u00dcberblick zu erhalten. Vergleichen Sie die lokale Sendeleistung (TX) mit der entfernten Empfangsleistung (RX) f\u00fcr dieselbe Richtung und verwenden Sie die genauen minimalen und maximalen Betriebsgrenzen des jeweiligen Moduls. Es gibt keinen allgemeing\u00fcltigen \u201cguten\u201d dBm-Wert.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-ab588b48\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22363\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-4af6aad6\">Ein kontrollierter Workflow f\u00fcr LOS- und TX-Fehler bei RX<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-121a61f3\">1. Halten Sie die genaue Konfiguration fest<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c974b8bc\">Speichern Sie sowohl die Host-Modelle als auch die Ports, die Firmware- und Treiberversionen, die Modul-Teilenummern und -Revisionen, die Codierung, den optischen PMD-Wert, die konfigurierte oder ausgehandelte \u00dcbertragungsrate, die FEC sowie den Port-Modus. Zeichnen Sie gleichzeitig den Status beider Seiten, die DDM-Werte, die Verbindungsereignisse und die Fehlerz\u00e4hler auf.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-24c33d1f\">Die Bezeichnung \u201eSFP\u201c, \u201eSFP+\u201c oder \u201eSFP28\u201c sagt nichts \u00fcber die Kompatibilit\u00e4t aus. Die physische Passform, der SerDes-Modus des Hosts, die Codierung des Moduls, die tats\u00e4chliche Betriebsrate und der nutzbare Durchsatz sind jeweils f\u00fcr sich stehende Faktoren.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-ba2b92a9\">2. \u00dcberpr\u00fcfen Sie das Etikett und geben Sie den Zustand an<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d20cf8c9\">Lesen Sie die genaue Plattformdefinition f\u00fcr <code>RX LOS<\/code>, <code>Signalerfassung<\/code>, <code>RX-Fehler<\/code>, <code>TX-Fehler<\/code> und <code>TX deaktivieren<\/code>. Warten Sie, bis das Modul nach dem Start g\u00fcltige Daten meldet, und \u00fcberpr\u00fcfen Sie anschlie\u00dfend mit einer zweiten Abfrage, ob der Status dauerhaft ist.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f4e7bc18\">Gehen Sie nicht davon aus, dass <code>1<\/code> bedeutet immer \u201egesund\u201c oder dass ein gr\u00fcnes Symbol auf dem Dashboard den tats\u00e4chlichen Zustand au\u00dfer Kraft setzt.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-6acf6eef\">3. Beide Richtungen auf der Karte eintragen<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-052bc45f\">Schreibe den Link als zwei Pfade:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>A (Sender) \u2192 B (Empf\u00e4nger)<\/strong><\/li>\n\n\n\n<li><strong>B TX \u2192 A RX<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-39258fdd\">Wenn B eine RX-LOS-Meldung hat, \u00fcberpr\u00fcfe den ersten Pfad. Wenn B einen TX-Fehler hat und A eine RX-LOS-Meldung hat, stimmen die beiden Beobachtungen hinsichtlich der <strong>B TX \u2192 A RX<\/strong> Richtung und machen die Sendeseite von B zu einem wahrscheinlicheren Kandidaten. Sie schlie\u00dfen jedoch weiterhin einen Fehler auf der Host-Seite, eine Deaktivierung der Sendeseite (TX Disable) oder einen zweiten Fehler nicht aus.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-be76f0b7\">4. \u00dcberpr\u00fcfen Sie die optische \u00dcbereinstimmung<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6029bfdf\">\u00dcberpr\u00fcfen Sie die \u00dcbertragungsrate und die PMD, die Faserkategorie, die Wellenl\u00e4nge, die Steckverbinderfamilie und die Politur, die Duplex-Polarit\u00e4t oder die BiDi-Kopplung sowie das Empfangsleistungsfenster in jeder Richtung. Ein passender Steckverbinder allein reicht nicht aus.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-cea0e60b\">\u00dcberpr\u00fcfen und reinigen Sie die zug\u00e4nglichen Anschl\u00fcsse gem\u00e4\u00df dem vom Netzwerkbetreiber genehmigten Verfahren. Die <a href=\"https:\/\/foa.org\/tech\/ref\/testing\/test\/scope.html\" target=\"_blank\" rel=\"noopener\">Leitfaden zu Steckverbindern der Fiber Optic Association<\/a> dokumentiert, wie Verunreinigungen zu Verlusten und Reflexionen f\u00fchren und zwischen ineinander gesteckten Ferrulen \u00fcbertragen werden k\u00f6nnen. Schauen Sie niemals in eine Faser oder einen optischen Anschluss hinein; verwenden Sie stattdessen ein geeignetes Leistungsmessger\u00e4t und eine Videoinspektionsmethode.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-59a1521d\">5. Eine Komponente isolieren<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-af1656ae\">Ersetzen Sie w\u00e4hrend eines genehmigten Wartungsfensters ein bekannterma\u00dfen einwandfreies, korrekt spezifiziertes Patchkabel oder Modul und wiederholen Sie die gleichen Beobachtungen. Wenn der Fehler einem Modul zwischen den unterst\u00fctzten Ports folgt, st\u00fctzt dies die Modulhypothese. Wenn der RX-LOS-Fehler in einer Glasfaserrichtung auftritt, \u00fcberpr\u00fcfen Sie diesen Pfad. Wenn er an einem Host-Port auftritt, untersuchen Sie den Host und die Konfiguration.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f8dcf4e9\">Ein lokaler Loopback kann den lokalen Pfad verk\u00fcrzen, jedoch erst nach Abstimmung von PMD, Glasfaser, Stecker und Empf\u00e4ngerleistung. LuLeeys <a href=\"https:\/\/www.luleey.com\/de\/how-to-test-an-sfp-port-with-a-fiber-loopback\/\">Anleitung zum Glasfaser-Loopback-Test<\/a> erl\u00e4utert die Einschr\u00e4nkungen: Bei einer erfolgreichen Schleife werden weder der Produktionsstamm noch der entfernte Peer getestet, und eine passive Selbstschleife ist kein g\u00fcltiger allgemeiner Test f\u00fcr BiDi-Optiken mit komplement\u00e4ren Wellenl\u00e4ngen.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-eca936c6\">6. \u00dcberpr\u00fcfen Sie den Datenverkehr, nicht nur den Status<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f165184f\">Nachdem der Status zur\u00fcckgesetzt wurde, \u00fcberpr\u00fcfen Sie den stabilen Verbindungsstatus, die tats\u00e4chliche \u00dcbertragungsrate und die neuen Z\u00e4hlerdifferenzen in beiden Richtungen. Dass \u201eRX LOS\u201c nicht mehr angezeigt wird, bedeutet lediglich, dass diese bestimmte Verlustanzeige nicht mehr vorliegt. Dies ist kein Nachweis f\u00fcr fehlerfreie Ethernet-Frames oder den erwarteten Durchsatz.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2d5d1d13\">Wenn die Verbindung besteht, aber die FCS-\/CRC-Fehler zunehmen, fahren Sie mit LuLeeys Verfahren fort. <a href=\"https:\/\/www.luleey.com\/de\/sfp-crc-errors-with-normal-rx-power-what-to-check\/\">Checkliste zur Fehlerbehebung bei SFP-CRC<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-72dab416\">H\u00e4ufige Fehler, die es zu vermeiden gilt<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Der Austausch des Empf\u00e4ngers von B allein aufgrund der Meldung \u201eRX LOS\u201c durch B<\/li>\n\n\n\n<li>\u201eTX Disable\u201c als Hinweis auf einen TX-Fehler behandeln<\/li>\n\n\n\n<li>Auslesen der lokalen TX- und RX-Werte als eine optische Richtung<\/li>\n\n\n\n<li>Gleichzeitiger Austausch beider Optiken und beider Patchkabel<\/li>\n\n\n\n<li>Verwendung einer allgemeinen Wellenl\u00e4ngen- oder dBm-Regel anstelle der genauen Angaben aus den Datenbl\u00e4ttern<\/li>\n\n\n\n<li>Erfolgsmeldung, wenn der Alarm zur\u00fcckgesetzt wird, ohne den Datenverkehr und die Z\u00e4hler zu \u00fcberpr\u00fcfen<\/li>\n\n\n\n<li>Einstellungen f\u00fcr Host-SerDes, \u00dcbertragungsrate, FEC, Codierung, Firmware oder Anschl\u00fcsse werden ignoriert<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5795d495\">Dieser Arbeitsablauf ist keine Anleitung zur PON-Registrierung. Ein 2,5G-PON-ONU-Stick enth\u00e4lt ONU-Logik und kann das Host-Verhalten anders darstellen. Ein 1G\/10G-SFP+-Host kann ihn nur mit 1G betreiben, wenn sowohl der Stick als auch der Host einen kompatiblen 1G-Modus unterst\u00fctzen; einige SFP+-Ports unterst\u00fctzen 2,5G nur mit dem richtigen Chipsatz\/PHY, der richtigen Firmware oder dem richtigen Treiber, den richtigen Port-Einstellungen, der richtigen Modulcodierung und dem richtigen Stick-Host-Modus.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-4454f2f7\">Wo LuLeey-Ger\u00e4te zum Einsatz kommen<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9a4475c4\">F\u00fcr einen kontrollierten lokalen Multimode-Test bietet LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/de\/produkt-2\/fiber-optic-loopback-lc-upc-om3-mm\/\">LC\/UPC OM3-Glasfaser-Loopback<\/a> Auf der Seite sind ein Multimode-Kabel mit 50\/125 \u00b5m, eine LC\/UPC-Schnittstelle und eine Einf\u00fcged\u00e4mpfung von h\u00f6chstens 0,2 dB angegeben. Diese Spezifikationen machen das Kabel jedoch nicht universell einsetzbar. Der angegebene Wert ist eine maximale D\u00e4mpfung, keine garantierte Schutzd\u00e4mpfung; \u00fcberpr\u00fcfen Sie die genaue PMD und die maximale Eingangsleistung des Empf\u00e4ngers, bevor Sie eine kurze Schleife bilden.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-15a60686\">F\u00fcr eine Ersatz- oder Kompatibilit\u00e4tspr\u00fcfung senden Sie LuLeey bitte folgende Informationen: beide Host-Modelle, Modulbezeichnungen und -revisionen, Firmware, Port-Modus, Angaben zu Glasfaser und Steckverbindern, die TX-Fault-\/RX-LOS-\/TX-Disable-Zust\u00e4nde an beiden Enden, vollst\u00e4ndige DDM-Snapshots, Zeitstempel der Link-Ereignisse sowie Z\u00e4hlerdifferenzen.<\/p>","protected":false},"excerpt":{"rendered":"<p>An Ger\u00e4t B angezeigter Status Was das Modul meldet Erster zu pr\u00fcfender Punkt Was es nicht belegt RX<\/p>","protected":false},"author":1,"featured_media":22362,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[886],"tags":[69,1680,1642,1669,1682,71,1681],"class_list":["post-22361","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-network-maintenance","tag-sfp","tag-loss-of-signal","tag-network-maintenance","tag-optical-troubleshooting","tag-rx-los","tag-sfp-2","tag-tx-fault"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/posts\/22361","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/comments?post=22361"}],"version-history":[{"count":1,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/posts\/22361\/revisions"}],"predecessor-version":[{"id":22372,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/posts\/22361\/revisions\/22372"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/media\/22362"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/media?parent=22361"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/categories?post=22361"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/tags?post=22361"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}