{"id":12474,"date":"2024-07-19T00:51:54","date_gmt":"2024-07-18T16:51:54","guid":{"rendered":"https:\/\/www.luleey.com\/?post_type=product&#038;p=12474"},"modified":"2026-10-04T00:24:33","modified_gmt":"2026-10-03T16:24:33","slug":"10g-sfp-aoc-active-optical-cables","status":"publish","type":"product","link":"https:\/\/www.luleey.com\/de\/produkt-2\/10g-sfp-aoc-active-optical-cables\/","title":{"rendered":"10G-SFP+-Aktivkabel, SFP+ auf SFP+, 3 m\u201310 m"},"content":{"rendered":"<h2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1ql1n7r\" data-start=\"2297\" data-end=\"2338\">\u00dcbersicht \u00fcber aktive optische 10G-SFP+-Kabel<\/h2>\n<p data-start=\"2340\" data-end=\"2479\">Die <strong data-start=\"2344\" data-end=\"2377\">Aktives optisches 10G-SFP+-Kabel<\/strong> stellt eine direkte optische Verbindung zwischen zwei Netzwerkger\u00e4ten her, die \u00fcber kompatible SFP+-Anschl\u00fcsse verf\u00fcgen.<\/p>\n<p data-start=\"2481\" data-end=\"2787\">An jedem Ende ist ein optischer SFP+-Transceiver integriert, der fest mit der internen Multimode-Faser verbunden ist, sodass eine komplette Kabelbaugruppe entsteht. Dadurch entf\u00e4llt die Anschaffung von zwei separaten optischen Modulen und eines zus\u00e4tzlichen Glasfaser-Patchkabels, und gleichzeitig wird die Anzahl der freiliegenden optischen Anschlusspunkte reduziert.<\/p>\n<p data-start=\"2789\" data-end=\"3049\">Das Kabel unterst\u00fctzt Datenraten von bis zu 10,312 Gbit\/s und nutzt ein optisches \u00dcbertragungssystem mit einer Wellenl\u00e4nge von 850 nm. Als Standardl\u00e4ngen stehen 3 m, 5 m und 10 m zur Auswahl, wodurch es sich f\u00fcr Verbindungen innerhalb eines Racks, zwischen benachbarten Racks und zwischen nahegelegenen Schr\u00e4nken im Rechenzentrum eignet.<\/p>\n<p data-start=\"3051\" data-end=\"3334\">Im Vergleich zu Kupfer-DAC-Kabeln bietet ein AOC ein geringeres Kabelgewicht, eine bessere St\u00f6rfestigkeit gegen\u00fcber elektromagnetischen St\u00f6rungen und gr\u00f6\u00dfere Flexibilit\u00e4t bei l\u00e4ngeren Verbindungen \u00fcber kurze Entfernungen. Es eignet sich f\u00fcr Verbindungen zwischen Switches, zwischen Switches und Servern, zwischen Switches und Netzwerkkarten sowie zwischen Switches und Speichersystemen.<\/p>\n<p data-start=\"3336\" data-end=\"3537\">Kompatibilit\u00e4tscodierung ist f\u00fcr Cisco, Arista, Juniper, Huawei, H3C, HPE Aruba, Intel, Mellanox, MikroTik, Ubiquiti, TP-Link, ZTE, Brocade, Extreme, Alcatel-Lucent und andere unterst\u00fctzte Plattformen verf\u00fcgbar.<\/p>\n<p data-start=\"3539\" data-end=\"3739\">Bei der Bestellung sollte das genaue Ger\u00e4temodell angegeben werden. Bei Verbindungen zwischen zwei verschiedenen Ger\u00e4temarken sollten beide Endger\u00e4temodelle angegeben werden, damit die Kodierungsanforderungen \u00fcberpr\u00fcft werden k\u00f6nnen.<\/p>\n<h2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1ma7m6t\" data-start=\"3876\" data-end=\"3891\">Wesentliche Merkmale<\/h2>\n<ul data-start=\"3893\" data-end=\"4329\">\n<li data-section-id=\"m5l2u0\" data-start=\"3893\" data-end=\"3927\">SFP+-Stecker an beiden Enden<\/li>\n<li data-section-id=\"15lbl11\" data-start=\"3928\" data-end=\"3964\">Maximale Daten\u00fcbertragungsrate von bis zu 10,312 Gbit\/s<\/li>\n<li data-section-id=\"pifn2g\" data-start=\"3965\" data-end=\"4007\">Integrierte aktive optische Kabelbaugruppe<\/li>\n<li data-section-id=\"1uzhfdy\" data-start=\"4008\" data-end=\"4046\">Optische \u00dcbertragung im Multimode-Modus bei 850 nm<\/li>\n<li data-section-id=\"14hkqvh\" data-start=\"4047\" data-end=\"4078\">Hot-Plug-f\u00e4hige SFP+-Schnittstellen<\/li>\n<li data-section-id=\"1dznpul\" data-start=\"4079\" data-end=\"4113\">Standardl\u00e4ngen von 3 m, 5 m und 10 m<\/li>\n<li data-section-id=\"1u12udi\" data-start=\"4114\" data-end=\"4140\">Einzelne 3,3-V-Stromversorgung<\/li>\n<li data-section-id=\"ntept0\" data-start=\"4141\" data-end=\"4162\">SFP+ MSA-Konformit\u00e4t<\/li>\n<li data-section-id=\"sb0uup\" data-start=\"4163\" data-end=\"4187\">SFF-8472-Kompatibilit\u00e4t<\/li>\n<li data-section-id=\"17y53bf\" data-start=\"4188\" data-end=\"4229\">Bessere EMI-St\u00f6rfestigkeit als bei Kupferkabeln<\/li>\n<li data-section-id=\"ysamlo\" data-start=\"4230\" data-end=\"4280\">Integrierte Bauweise ohne externe LC-Anschl\u00fcsse<\/li>\n<li data-section-id=\"5crp3y\" data-start=\"4281\" data-end=\"4329\">Herstellerspezifische Kompatibilit\u00e4tscodierung verf\u00fcgbar<\/li>\n<\/ul>\n<h2 data-section-id=\"mu966k\" data-start=\"4331\" data-end=\"4346\">Anwendungen<\/h2>\n<ul data-start=\"4348\" data-end=\"4672\">\n<li data-section-id=\"935ydv\" data-start=\"4348\" data-end=\"4384\">Verbindung von Switches in Rechenzentren<\/li>\n<li data-section-id=\"wmryo1\" data-start=\"4385\" data-end=\"4415\">Verbindungen vom Switch zum Server<\/li>\n<li data-section-id=\"1ayki5f\" data-start=\"4416\" data-end=\"4452\">Verbindungen zwischen Switch und Netzwerkkarte<\/li>\n<li data-section-id=\"1a72l8d\" data-start=\"4453\" data-end=\"4484\">Verbindungen vom Switch zum Speicher<\/li>\n<li data-section-id=\"1xqxcjl\" data-start=\"4485\" data-end=\"4515\">Verbindung zwischen zwei Racks<\/li>\n<li data-section-id=\"1wmtik1\" data-start=\"4516\" data-end=\"4543\">10-GbE-Netzwerke f\u00fcr Unternehmen<\/li>\n<li data-section-id=\"9fyg3n\" data-start=\"4544\" data-end=\"4572\">Hochleistungsrechnen<\/li>\n<li data-section-id=\"hmeze3\" data-start=\"4573\" data-end=\"4596\">Speichernetzwerke<\/li>\n<li data-section-id=\"10bdg6x\" data-start=\"4597\" data-end=\"4631\">1G-, 2G-, 4G- und 8G-Fibre-Channel<\/li>\n<li data-section-id=\"1klxv80\" data-start=\"4632\" data-end=\"4672\">Systemkaskade und interne Datenverbindungen<\/li>\n<\/ul>\n<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"54pib2\" data-start=\"4819\" data-end=\"4847\">Technische Daten<\/h1>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"4849\" data-end=\"5446\">\n<thead data-start=\"4849\" data-end=\"4878\">\n<tr data-start=\"4849\" data-end=\"4878\">\n<th class=\"last:pe-10\" data-start=\"4849\" data-end=\"4861\" data-col-size=\"sm\">Parameter<\/th>\n<th class=\"last:pe-10\" data-start=\"4861\" data-end=\"4878\" data-col-size=\"sm\">Spezifikation<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"4889\" data-end=\"5446\">\n<tr data-start=\"4889\" data-end=\"4907\">\n<td data-start=\"4889\" data-end=\"4897\" data-col-size=\"sm\">Marke<\/td>\n<td data-start=\"4897\" data-end=\"4907\" data-col-size=\"sm\">Luleey<\/td>\n<\/tr>\n<tr data-start=\"4908\" data-end=\"4929\">\n<td data-start=\"4908\" data-end=\"4916\" data-col-size=\"sm\">Modell<\/td>\n<td data-start=\"4916\" data-end=\"4929\" data-col-size=\"sm\">LL-10GAOC<\/td>\n<\/tr>\n<tr data-start=\"4930\" data-end=\"4969\">\n<td data-start=\"4930\" data-end=\"4945\" data-col-size=\"sm\">Produkttyp<\/td>\n<td data-start=\"4945\" data-end=\"4969\" data-col-size=\"sm\">Aktives optisches Kabel<\/td>\n<\/tr>\n<tr data-start=\"4970\" data-end=\"5003\">\n<td data-start=\"4970\" data-end=\"4987\" data-col-size=\"sm\">Host-Schnittstelle<\/td>\n<td data-start=\"4987\" data-end=\"5003\" data-col-size=\"sm\">SFP+ zu SFP+<\/td>\n<\/tr>\n<tr data-start=\"5004\" data-end=\"5038\">\n<td data-start=\"5004\" data-end=\"5024\" data-col-size=\"sm\">Maximale Daten\u00fcbertragungsrate<\/td>\n<td data-start=\"5024\" data-end=\"5038\" data-col-size=\"sm\">10,312 Gbit\/s<\/td>\n<\/tr>\n<tr data-start=\"5039\" data-end=\"5079\">\n<td data-start=\"5039\" data-end=\"5064\" data-col-size=\"sm\">\u00dcbertragungsrichtung<\/td>\n<td data-start=\"5064\" data-end=\"5079\" data-col-size=\"sm\">Vollduplex<\/td>\n<\/tr>\n<tr data-start=\"5080\" data-end=\"5110\">\n<td data-start=\"5080\" data-end=\"5101\" data-col-size=\"sm\">Optische Wellenl\u00e4nge<\/td>\n<td data-start=\"5101\" data-end=\"5110\" data-col-size=\"sm\">850nm<\/td>\n<\/tr>\n<tr data-start=\"5111\" data-end=\"5160\">\n<td data-start=\"5111\" data-end=\"5133\" data-col-size=\"sm\">\u00dcbertragungsmedium<\/td>\n<td data-start=\"5133\" data-end=\"5160\" data-col-size=\"sm\">Multimode-Lichtwellenleiter<\/td>\n<\/tr>\n<tr data-start=\"5161\" data-end=\"5196\">\n<td data-start=\"5161\" data-end=\"5181\" data-col-size=\"sm\">Verf\u00fcgbare L\u00e4ngen<\/td>\n<td data-start=\"5181\" data-end=\"5196\" data-col-size=\"sm\">3 m, 5 m, 10 m<\/td>\n<\/tr>\n<tr data-start=\"5197\" data-end=\"5220\">\n<td data-start=\"5197\" data-end=\"5212\" data-col-size=\"sm\">Stromversorgung<\/td>\n<td data-start=\"5212\" data-end=\"5220\" data-col-size=\"sm\">3.3V<\/td>\n<\/tr>\n<tr data-start=\"5221\" data-end=\"5253\">\n<td data-start=\"5221\" data-end=\"5236\" data-col-size=\"sm\">Installation<\/td>\n<td data-start=\"5236\" data-end=\"5253\" data-col-size=\"sm\">Im laufenden Betrieb austauschbar<\/td>\n<\/tr>\n<tr data-start=\"5254\" data-end=\"5293\">\n<td data-start=\"5254\" data-end=\"5278\" data-col-size=\"sm\">Betriebstemperatur<\/td>\n<td data-start=\"5278\" data-end=\"5293\" data-col-size=\"sm\">0\u00b0C bis 70\u00b0C<\/td>\n<\/tr>\n<tr data-start=\"5294\" data-end=\"5328\">\n<td data-start=\"5294\" data-end=\"5306\" data-col-size=\"sm\">Normen<\/td>\n<td data-start=\"5306\" data-end=\"5328\" data-col-size=\"sm\">SFP+ MSA, SFF-8472<\/td>\n<\/tr>\n<tr data-start=\"5329\" data-end=\"5382\">\n<td data-start=\"5329\" data-end=\"5352\" data-col-size=\"sm\">Kompatibilit\u00e4tscodierung<\/td>\n<td data-start=\"5352\" data-end=\"5382\" data-col-size=\"sm\">Herstellerspezifisch oder generisch<\/td>\n<\/tr>\n<tr data-start=\"5383\" data-end=\"5446\">\n<td data-start=\"5383\" data-end=\"5410\" data-col-size=\"sm\">Externer Glasfaserstecker<\/td>\n<td data-start=\"5410\" data-end=\"5446\" data-col-size=\"sm\">Keine \u2014 Integrierte Kabelbaugruppe<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p data-start=\"1674\" data-end=\"1823\">Der Luleey <strong data-start=\"1685\" data-end=\"1718\">Aktives optisches 10G-SFP+-Kabel<\/strong> bietet eine direkte optische Verbindung mit 10,312 Gbit\/s (SFP+ zu SFP+) f\u00fcr Switches, Server, Netzwerkkarten und Speichersysteme.<\/p>\n<ul data-start=\"1825\" data-end=\"2234\">\n<li data-section-id=\"1dp8055\" data-start=\"1825\" data-end=\"1866\">Integrierte SFP+-Anschl\u00fcsse an beiden Enden<\/li>\n<li data-section-id=\"1sgy20i\" data-start=\"1867\" data-end=\"1905\">Unterst\u00fctzt Datenraten von bis zu 10,312 Gbit\/s<\/li>\n<li data-section-id=\"1uzhfdy\" data-start=\"1906\" data-end=\"1944\">Optische \u00dcbertragung im Multimode-Modus bei 850 nm<\/li>\n<li data-section-id=\"1vushef\" data-start=\"1945\" data-end=\"1975\">Erh\u00e4ltlich in den L\u00e4ngen 3 m, 5 m und 10 m<\/li>\n<li data-section-id=\"14hkqvh\" data-start=\"1976\" data-end=\"2007\">Hot-Plug-f\u00e4hige SFP+-Schnittstellen<\/li>\n<li data-section-id=\"mdgnxk\" data-start=\"2008\" data-end=\"2046\">Entspricht der SFP+ MSA und der Norm SFF-8472<\/li>\n<li data-section-id=\"1u12udi\" data-start=\"2047\" data-end=\"2073\">Einzelne 3,3-V-Stromversorgung<\/li>\n<li data-section-id=\"zngi6r\" data-start=\"2074\" data-end=\"2121\">Betriebstemperatur im gewerblichen Einsatz: 0 \u00b0C bis 70 \u00b0C<\/li>\n<li data-section-id=\"b78hj\" data-start=\"2122\" data-end=\"2174\">Verbesserte St\u00f6rfestigkeit gegen\u00fcber elektromagnetischen St\u00f6rungen im Vergleich zu Kupferkabeln<\/li>\n<li data-section-id=\"1en8qet\" data-start=\"2175\" data-end=\"2234\">Kompatibilit\u00e4tscodes f\u00fcr die wichtigsten Ger\u00e4temarken verf\u00fcgbar<\/li>\n<\/ul>","protected":false},"featured_media":12530,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[351],"product_tag":[97,1368,1367,178,181,1366,838,322],"class_list":["post-12474","product","type-product","status-publish","has-post-thumbnail","product_cat-aoc-cable-10g-25g-40g-100g","product_tag-10g","product_tag-10g-data-center-cable","product_tag-10g-sfp-aoc","product_tag-active-optical-cable","product_tag-aoc","product_tag-aoc-cable","product_tag-sfp-cable","product_tag-sfp","first","instock","shipping-taxable","purchasable","product-type-variable","has-default-attributes"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product\/12474","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/comments?post=12474"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/media\/12530"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/media?parent=12474"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product_brand?post=12474"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product_cat?post=12474"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product_tag?post=12474"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}