{"id":12608,"date":"2024-07-19T00:53:55","date_gmt":"2024-07-18T16:53:55","guid":{"rendered":"https:\/\/www.luleey.com\/?post_type=product&#038;p=12608"},"modified":"2026-10-03T23:59:52","modified_gmt":"2026-10-03T15:59:52","slug":"1ge-catv-onu-xpon-gpon-epon-onu-1gecatvscapc","status":"publish","type":"product","link":"https:\/\/www.luleey.com\/de\/produkt-2\/1ge-catv-onu-xpon-gpon-epon-onu-1gecatvscapc\/","title":{"rendered":"1GE-CATV-ONU, XPON GPON\/EPON Dual-Mode, SC\/APC"},"content":{"rendered":"<h2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"ntvrnl\" data-start=\"2693\" data-end=\"2717\">1GE CATV ONU \u2013 \u00dcberblick<\/h2>\n<p data-start=\"2719\" data-end=\"2876\">Die <strong data-start=\"2723\" data-end=\"2739\">1GE-CATV-ONU<\/strong> ist eine kompakte optische XPON-Netzwerkeinheit, die daf\u00fcr ausgelegt ist, Gigabit-Ethernet- und CATV-Videodienste \u00fcber eine einzige FTTH-Glasfaserverbindung bereitzustellen.<\/p>\n<p data-start=\"2878\" data-end=\"3222\">Es unterst\u00fctzt die automatische GPON- und EPON-Erkennung, sodass die ONU mit kompatiblen GPON- oder EPON-OLT-Netzwerken betrieben werden kann, ohne dass ein anderes Hardwaremodell erforderlich ist. Die PON-Schnittstelle verwendet einen SC\/APC-Stecker mit Wellenl\u00e4ngen von 1310 nm im Upstream- und 1490 nm im Downstream-Bereich, w\u00e4hrend der integrierte CATV-Empf\u00e4nger ein optisches Videosignal mit 1550 \u00b1 10 nm unterst\u00fctzt.<\/p>\n<p data-start=\"3224\" data-end=\"3500\">Ein 10\/100\/1000 Mbit\/s RJ45-Ethernet-Anschluss bietet Gigabit-Netzwerkzugang f\u00fcr einen Router, einen Computer, einen Switch oder ein anderes Ethernet-Ger\u00e4t. Die separate 75-\u03a9-CATV-HF-Schnittstelle wandelt das empfangene optische CATV-Signal mit 1550 nm um, um den Anschluss an kompatible Fernsehverteilungsger\u00e4te zu erm\u00f6glichen.<\/p>\n<p data-start=\"3502\" data-end=\"3723\">Die ONU unterst\u00fctzt die Webkonfiguration, IGMP-Snooping und den automatischen MDI\/MDIX-Betrieb. Sie eignet sich f\u00fcr FTTH-Installationen, bei denen Breitbanddaten und herk\u00f6mmliche CATV-Dienste ohne WLAN oder zus\u00e4tzliche Ethernet-Anschl\u00fcsse ben\u00f6tigt werden.<\/p>\n<p data-start=\"3725\" data-end=\"4040\">Der Standard-Firmware-Modus ist SFU. HGU-Firmware ist auf Anfrage erh\u00e4ltlich. Die tats\u00e4chliche Kompatibilit\u00e4t mit OLT und ISP h\u00e4ngt von der erforderlichen Authentifizierungsmethode, dem ONU-Profil, dem Service-VLAN und der Netzwerkkonfiguration ab. Daher sollten das OLT-Modell und die Authentifizierungsanforderungen vor dem Austausch einer vom ISP bereitgestellten ONU \u00fcberpr\u00fcft werden.<\/p>\n<h2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1ma7m6t\" data-start=\"4166\" data-end=\"4181\">Wesentliche Merkmale<\/h2>\n<ul data-start=\"4183\" data-end=\"4570\">\n<li data-section-id=\"1por38r\" data-start=\"4183\" data-end=\"4219\">XPON-Betrieb im Dual-Mode-Modus (GPON\/EPON)<\/li>\n<li data-section-id=\"5xx9ti\" data-start=\"4220\" data-end=\"4260\">Automatische GPON- und EPON-Erkennung<\/li>\n<li data-section-id=\"14883xk\" data-start=\"4261\" data-end=\"4292\">1\u00d7 Gigabit-Ethernet-RJ45-Anschluss<\/li>\n<li data-section-id=\"mqjqyv\" data-start=\"4293\" data-end=\"4319\">1\u00d7 1550 nm CATV-HF-Ausgang<\/li>\n<li data-section-id=\"yyor8d\" data-start=\"4320\" data-end=\"4350\">Optische Schnittstelle SC\/APC PON<\/li>\n<li data-section-id=\"1pgumeu\" data-start=\"4351\" data-end=\"4389\">PON-\u00dcbertragungsreichweite von bis zu 20 km<\/li>\n<li data-section-id=\"6l1z2s\" data-start=\"4390\" data-end=\"4415\">Webbasierte Konfiguration<\/li>\n<li data-section-id=\"s8nk3d\" data-start=\"4416\" data-end=\"4439\">Unterst\u00fctzung von IGMP-Snooping<\/li>\n<li data-section-id=\"3t4kci\" data-start=\"4440\" data-end=\"4460\">Automatische MDI\/MDIX-Erkennung<\/li>\n<li data-section-id=\"1gw2ull\" data-start=\"4461\" data-end=\"4486\">SFU-Firmware (Standard)<\/li>\n<li data-section-id=\"ih64tm\" data-start=\"4487\" data-end=\"4522\">HGU-Firmware auf Anfrage erh\u00e4ltlich<\/li>\n<li data-section-id=\"i92wig\" data-start=\"4523\" data-end=\"4570\">Entwickelt f\u00fcr FTTH-Breitband- und CATV-Dienste<\/li>\n<\/ul>\n<h2 data-section-id=\"mu966k\" data-start=\"4572\" data-end=\"4587\">Anwendungen<\/h2>\n<ul data-start=\"4589\" data-end=\"4840\">\n<li data-section-id=\"1mffawh\" data-start=\"4589\" data-end=\"4612\">FTTH-Breitbandzugang<\/li>\n<li data-section-id=\"1o1k1pl\" data-start=\"4613\" data-end=\"4639\">GPON-Teilnehmernetze<\/li>\n<li data-section-id=\"1phdb3f\" data-start=\"4640\" data-end=\"4666\">EPON-Teilnehmernetze<\/li>\n<li data-section-id=\"1hrggfw\" data-start=\"4667\" data-end=\"4684\">Kabelfernsehen \u00fcber Glasfaser<\/li>\n<li data-section-id=\"1lppglx\" data-start=\"4685\" data-end=\"4720\">Internet- und TV-Angebot f\u00fcr Privathaushalte<\/li>\n<li data-section-id=\"1sh93l0\" data-start=\"4721\" data-end=\"4744\">SOHO-Breitbandzugang<\/li>\n<li data-section-id=\"11hwiuu\" data-start=\"4745\" data-end=\"4777\">Standorte von ISP- und WISP-Kunden<\/li>\n<li data-section-id=\"zklcla\" data-start=\"4778\" data-end=\"4815\">Netze von Telekommunikations- und Kabelnetzbetreibern<\/li>\n<li data-section-id=\"3lzwfg\" data-start=\"4816\" data-end=\"4840\">PON-Laboruntersuchungen<\/li>\n<\/ul>\n<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"54pib2\" data-start=\"4847\" data-end=\"4875\">Technische Daten<\/h1>\n<div class=\"group TyagGW_tableContainer\">\n<div class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"4877\" data-end=\"6017\">\n<thead data-start=\"4877\" data-end=\"4906\">\n<tr data-start=\"4877\" data-end=\"4906\">\n<th class=\"last:pe-10\" data-start=\"4877\" data-end=\"4889\" data-col-size=\"sm\">Parameter<\/th>\n<th class=\"last:pe-10\" data-start=\"4889\" data-end=\"4906\" data-col-size=\"sm\">Spezifikation<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"4917\" data-end=\"6017\">\n<tr data-start=\"4917\" data-end=\"4935\">\n<td data-start=\"4917\" data-end=\"4925\" data-col-size=\"sm\">Marke<\/td>\n<td data-start=\"4925\" data-end=\"4935\" data-col-size=\"sm\">Luleey<\/td>\n<\/tr>\n<tr data-start=\"4936\" data-end=\"4957\">\n<td data-start=\"4936\" data-end=\"4944\" data-col-size=\"sm\">Modell<\/td>\n<td data-start=\"4944\" data-end=\"4957\" data-col-size=\"sm\">LL-XP1G1C<\/td>\n<\/tr>\n<tr data-start=\"4958\" data-end=\"4994\">\n<td data-start=\"4958\" data-end=\"4973\" data-col-size=\"sm\">Produkttyp<\/td>\n<td data-start=\"4973\" data-end=\"4994\" data-col-size=\"sm\">1GE-CATV-XPON-ONU<\/td>\n<\/tr>\n<tr data-start=\"4995\" data-end=\"5037\">\n<td data-start=\"4995\" data-end=\"5012\" data-col-size=\"sm\">PON-Technologie<\/td>\n<td data-start=\"5012\" data-end=\"5037\" data-col-size=\"sm\">GPON\/EPON-Dualmodus<\/td>\n<\/tr>\n<tr data-start=\"5038\" data-end=\"5064\">\n<td data-start=\"5038\" data-end=\"5054\" data-col-size=\"sm\">PON-Anschluss<\/td>\n<td data-start=\"5054\" data-end=\"5064\" data-col-size=\"sm\">SC\/APC<\/td>\n<\/tr>\n<tr data-start=\"5065\" data-end=\"5082\">\n<td data-start=\"5065\" data-end=\"5077\" data-col-size=\"sm\">PON-Anschl\u00fcsse<\/td>\n<td data-start=\"5077\" data-end=\"5082\" data-col-size=\"sm\">1<\/td>\n<\/tr>\n<tr data-start=\"5083\" data-end=\"5117\">\n<td data-start=\"5083\" data-end=\"5104\" data-col-size=\"sm\">GPON-Upstream-Rate<\/td>\n<td data-start=\"5104\" data-end=\"5117\" data-col-size=\"sm\">1,244 Gbit\/s<\/td>\n<\/tr>\n<tr data-start=\"5118\" data-end=\"5154\">\n<td data-start=\"5118\" data-end=\"5141\" data-col-size=\"sm\">GPON-Downstream-Rate<\/td>\n<td data-start=\"5141\" data-end=\"5154\" data-col-size=\"sm\">2.488 Gbit\/s<\/td>\n<\/tr>\n<tr data-start=\"5155\" data-end=\"5189\">\n<td data-start=\"5155\" data-end=\"5176\" data-col-size=\"sm\">EPON-Upstream-Rate<\/td>\n<td data-start=\"5176\" data-end=\"5189\" data-col-size=\"sm\">1,244 Gbit\/s<\/td>\n<\/tr>\n<tr data-start=\"5190\" data-end=\"5226\">\n<td data-start=\"5190\" data-end=\"5213\" data-col-size=\"sm\">EPON-Downstream-Rate<\/td>\n<td data-start=\"5213\" data-end=\"5226\" data-col-size=\"sm\">1,244 Gbit\/s<\/td>\n<\/tr>\n<tr data-start=\"5227\" data-end=\"5263\">\n<td data-start=\"5227\" data-end=\"5253\" data-col-size=\"sm\">PON-Upstream-Wellenl\u00e4nge<\/td>\n<td data-start=\"5253\" data-end=\"5263\" data-col-size=\"sm\">1310nm<\/td>\n<\/tr>\n<tr data-start=\"5264\" data-end=\"5302\">\n<td data-start=\"5264\" data-end=\"5292\" data-col-size=\"sm\">PON-Downstream-Wellenl\u00e4nge<\/td>\n<td data-col-size=\"sm\" data-start=\"5292\" data-end=\"5302\">1490nm<\/td>\n<\/tr>\n<tr data-start=\"5303\" data-end=\"5342\">\n<td data-start=\"5303\" data-end=\"5326\" data-col-size=\"sm\">PON TX \u2013 Optische Leistung<\/td>\n<td data-col-size=\"sm\" data-start=\"5326\" data-end=\"5342\">0,5 bis +4 dBm<\/td>\n<\/tr>\n<tr data-start=\"5343\" data-end=\"5374\">\n<td data-start=\"5343\" data-end=\"5364\" data-col-size=\"sm\">PON-Empfangsempfindlichkeit<\/td>\n<td data-start=\"5364\" data-end=\"5374\" data-col-size=\"sm\">-27dBm<\/td>\n<\/tr>\n<tr data-start=\"5375\" data-end=\"5412\">\n<td data-start=\"5375\" data-end=\"5398\" data-col-size=\"sm\">Maximale PON-Reichweite<\/td>\n<td data-col-size=\"sm\" data-start=\"5398\" data-end=\"5412\">Bis zu 20 km<\/td>\n<\/tr>\n<tr data-start=\"5413\" data-end=\"5445\">\n<td data-start=\"5413\" data-end=\"5434\" data-col-size=\"sm\">Ethernet-Schnittstelle<\/td>\n<td data-col-size=\"sm\" data-start=\"5434\" data-end=\"5445\">1\u00d7 RJ45<\/td>\n<\/tr>\n<tr data-start=\"5446\" data-end=\"5498\">\n<td data-start=\"5446\" data-end=\"5462\" data-col-size=\"sm\">Ethernet-\u00dcbertragungsrate<\/td>\n<td data-start=\"5462\" data-end=\"5498\" data-col-size=\"sm\">10\/100\/1000 Mbit\/s Auto-Negotiation<\/td>\n<\/tr>\n<tr data-start=\"5499\" data-end=\"5532\">\n<td data-start=\"5499\" data-end=\"5516\" data-col-size=\"sm\">CATV-Schnittstelle<\/td>\n<td data-start=\"5516\" data-end=\"5532\" data-col-size=\"sm\">1\u00d7 HF-Ausgang<\/td>\n<\/tr>\n<tr data-start=\"5533\" data-end=\"5572\">\n<td data-start=\"5533\" data-end=\"5559\" data-col-size=\"sm\">Optische CATV-Wellenl\u00e4nge<\/td>\n<td data-start=\"5559\" data-end=\"5572\" data-col-size=\"sm\">1550\u00b110nm<\/td>\n<\/tr>\n<tr data-start=\"5573\" data-end=\"5616\">\n<td data-start=\"5573\" data-end=\"5600\" data-col-size=\"sm\">Optischer Eingangsbereich f\u00fcr CATV<\/td>\n<td data-col-size=\"sm\" data-start=\"5600\" data-end=\"5616\">-15 bis +2 dBm<\/td>\n<\/tr>\n<tr data-start=\"5617\" data-end=\"5653\">\n<td data-start=\"5617\" data-end=\"5644\" data-col-size=\"sm\">Optische R\u00fcckflussd\u00e4mpfung im Kabelfernsehen<\/td>\n<td data-start=\"5644\" data-end=\"5653\" data-col-size=\"sm\">\u226545 dB<\/td>\n<\/tr>\n<tr data-start=\"5654\" data-end=\"5689\">\n<td data-start=\"5654\" data-end=\"5675\" data-col-size=\"sm\">HF-Frequenzbereich<\/td>\n<td data-col-size=\"sm\" data-start=\"5675\" data-end=\"5689\">47\u20131000 MHz<\/td>\n<\/tr>\n<tr data-start=\"5690\" data-end=\"5719\">\n<td data-start=\"5690\" data-end=\"5712\" data-col-size=\"sm\">HF-Ausgangsimpedanz<\/td>\n<td data-start=\"5712\" data-end=\"5719\" data-col-size=\"sm\">75\u03a9<\/td>\n<\/tr>\n<tr data-start=\"5720\" data-end=\"5748\">\n<td data-start=\"5720\" data-end=\"5738\" data-col-size=\"sm\">HF-Ausgangspegel<\/td>\n<td data-start=\"5738\" data-end=\"5748\" data-col-size=\"sm\">78 dB\u03bcV<\/td>\n<\/tr>\n<tr data-start=\"5749\" data-end=\"5776\">\n<td data-start=\"5749\" data-end=\"5761\" data-col-size=\"sm\">AGC-Reihe<\/td>\n<td data-start=\"5761\" data-end=\"5776\" data-col-size=\"sm\">0 bis -12 dBm<\/td>\n<\/tr>\n<tr data-start=\"5777\" data-end=\"5801\">\n<td data-start=\"5777\" data-end=\"5783\" data-col-size=\"sm\">MER<\/td>\n<td data-start=\"5783\" data-end=\"5801\" data-col-size=\"sm\">\u226532 dB bei -15 dBm<\/td>\n<\/tr>\n<tr data-start=\"5802\" data-end=\"5836\">\n<td data-start=\"5802\" data-end=\"5815\" data-col-size=\"sm\">Verwaltung<\/td>\n<td data-start=\"5815\" data-end=\"5836\" data-col-size=\"sm\">Webkonfiguration<\/td>\n<\/tr>\n<tr data-start=\"5837\" data-end=\"5866\">\n<td data-start=\"5837\" data-end=\"5849\" data-col-size=\"sm\">Multicast<\/td>\n<td data-col-size=\"sm\" data-start=\"5849\" data-end=\"5866\">IGMP-Snooping<\/td>\n<\/tr>\n<tr data-start=\"5867\" data-end=\"5898\">\n<td data-start=\"5867\" data-end=\"5882\" data-col-size=\"sm\">Stromversorgung<\/td>\n<td data-start=\"5882\" data-end=\"5898\" data-col-size=\"sm\">12 V Gleichstrom, 0,5 A<\/td>\n<\/tr>\n<tr data-start=\"5899\" data-end=\"5926\">\n<td data-start=\"5899\" data-end=\"5919\" data-col-size=\"sm\">Stromverbrauch<\/td>\n<td data-col-size=\"sm\" data-start=\"5919\" data-end=\"5926\">&lt;6 W<\/td>\n<\/tr>\n<tr data-start=\"5927\" data-end=\"5969\">\n<td data-start=\"5927\" data-end=\"5951\" data-col-size=\"sm\">Betriebstemperatur<\/td>\n<td data-col-size=\"sm\" data-start=\"5951\" data-end=\"5969\">-10 \u00b0C bis +45 \u00b0C<\/td>\n<\/tr>\n<tr data-start=\"5970\" data-end=\"6017\">\n<td data-start=\"5970\" data-end=\"5991\" data-col-size=\"sm\">Luftfeuchtigkeit im Betrieb<\/td>\n<td data-start=\"5991\" data-end=\"6017\" data-col-size=\"sm\">5%\u201395%, nicht kondensierend<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"6294\" data-end=\"6577\"><strong data-start=\"6294\" data-end=\"6577\">Kompatibel mit g\u00e4ngigen GPON- und EPON-OLT-Plattformen. Die tats\u00e4chliche Aktivierung des Dienstes h\u00e4ngt vom OLT-Profil, der Authentifizierungsmethode, der VLAN-Konfiguration und den Anforderungen des Internetanbieters ab. Bitte geben Sie das OLT-Modell und die Authentifizierungsdaten an, wenn eine Kompatibilit\u00e4tspr\u00fcfung erforderlich ist.<\/strong><\/p>\n<p data-start=\"6579\" data-end=\"6583\">\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"1999\" data-end=\"2125\">Der Luleey <strong data-start=\"2010\" data-end=\"2026\">1GE-CATV-ONU<\/strong> Kombiniert GPON\/EPON-Dual-Mode, einen Gigabit-Ethernet-Anschluss und einen 1550-nm-CATV-HF-Ausgang f\u00fcr den FTTH-Zugang.<\/p>\n<ul data-start=\"2127\" data-end=\"2554\">\n<li data-section-id=\"goqenf\" data-start=\"2127\" data-end=\"2172\">Erkennt GPON- oder EPON-Netzwerke automatisch<\/li>\n<li data-section-id=\"1ie3jzg\" data-start=\"2173\" data-end=\"2215\">1\u00d7 10\/100\/1000 Mbit\/s Gigabit-Ethernet-Anschluss<\/li>\n<li data-section-id=\"ccf2wg\" data-start=\"2216\" data-end=\"2260\">1\u00d7 CATV-HF-Ausgang f\u00fcr 1550-nm-Videodienst<\/li>\n<li data-section-id=\"yyor8d\" data-start=\"2261\" data-end=\"2291\">Optische Schnittstelle SC\/APC PON<\/li>\n<li data-section-id=\"bhxra8\" data-start=\"2292\" data-end=\"2325\">GPON-Downstream mit bis zu 2,488 Gbit\/s<\/li>\n<li data-section-id=\"1erzyrs\" data-start=\"2326\" data-end=\"2363\">Symmetrische EPON-\u00dcbertragungsrate von bis zu 1,244 Gbit\/s<\/li>\n<li data-section-id=\"1v3pktd\" data-start=\"2364\" data-end=\"2410\">Unterst\u00fctzt Webkonfiguration und IGMP-Snooping<\/li>\n<li data-section-id=\"1pgumeu\" data-start=\"2411\" data-end=\"2449\">PON-\u00dcbertragungsreichweite von bis zu 20 km<\/li>\n<li data-section-id=\"1fnzgul\" data-start=\"2450\" data-end=\"2502\">Kompatibel mit g\u00e4ngigen GPON\/EPON-OLT-Plattformen<\/li>\n<li data-section-id=\"byfwwx\" data-start=\"2503\" data-end=\"2554\">Standardm\u00e4\u00dfig SFU-Firmware; HGU auf Anfrage erh\u00e4ltlich<\/li>\n<\/ul>","protected":false},"featured_media":17819,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[348,197],"product_tag":[89,1410,195,1411,944,230,1016,344],"class_list":["post-12608","product","type-product","status-publish","has-post-thumbnail","product_cat-1000m-gpon-epon-onu","product_cat-catv-receiver","product_tag-1000m","product_tag-1ge-catv-onu","product_tag-catv","product_tag-catv-onu","product_tag-epon-onu","product_tag-gpon-onu","product_tag-ll-xp1g1c","product_tag-xpon-onu","first","instock","featured","shipping-taxable","purchasable","product-type-variable","has-default-attributes"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product\/12608","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/comments?post=12608"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/media\/17819"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/media?parent=12608"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product_brand?post=12608"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product_cat?post=12608"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product_tag?post=12608"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}