{"id":12816,"date":"2024-07-19T00:56:49","date_gmt":"2024-07-18T16:56:49","guid":{"rendered":"https:\/\/www.luleey.com\/?post_type=product&#038;p=12816"},"modified":"2026-08-22T17:44:19","modified_gmt":"2026-08-22T09:44:19","slug":"8-port-2-5g-ethernet-switch-sfp-unmanaged-switch","status":"publish","type":"product","link":"https:\/\/www.luleey.com\/de\/produkt-2\/8-port-2-5g-ethernet-switch-sfp-unmanaged-switch\/","title":{"rendered":"8-Port-2,5-G-Ethernet-Switch mit 10-G-SFP+, unmanaged, l\u00fcfterlos"},"content":{"rendered":"<h2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"nz1uqy\" data-start=\"3487\" data-end=\"3526\">\u00dcbersicht \u00fcber den 8-Port-2,5-G-Ethernet-Switch<\/h2>\n<p data-start=\"3528\" data-end=\"3678\">Die <strong data-start=\"3532\" data-end=\"3563\">8-Port-2,5-G-Ethernet-Switch<\/strong> bietet acht Multi-Gigabit-RJ45-Anschl\u00fcsse und einen 10G-SFP+-Uplink zum Aufbau kompakter Hochgeschwindigkeits-Ethernet-Netzwerke.<\/p>\n<p data-start=\"3680\" data-end=\"3848\">Jeder RJ45-Anschluss unterst\u00fctzt die automatische Anpassung auf 10 Mbit\/s, 100 Mbit\/s, 1 Gbit\/s und 2,5 Gbit\/s, sodass sowohl herk\u00f6mmliche Gigabit-Ger\u00e4te als auch neuere 2,5-G-Ger\u00e4te im selben Netzwerk betrieben werden k\u00f6nnen.<\/p>\n<p data-start=\"3850\" data-end=\"4094\">Der zus\u00e4tzliche 10G-SFP+-Steckplatz bietet einen Uplink mit hoher Bandbreite f\u00fcr einen Core-Switch, einen Router, einen Server, ein NAS oder eine Glasfaserverbindung. Dadurch wird verhindert, dass der Uplink zu einem Engpass wird, wenn mehrere 2,5G-Ger\u00e4te gleichzeitig Daten \u00fcbertragen.<\/p>\n<p data-start=\"4096\" data-end=\"4234\">Mit einer Switching-Kapazit\u00e4t von 60 Gbit\/s und einer Store-and-Forward-Architektur unterst\u00fctzt der Switch eine blockierungsfreie Weiterleitung mit Leitungsgeschwindigkeit \u00fcber alle Ports hinweg.<\/p>\n<p data-start=\"4236\" data-end=\"4390\">Das unmanaged-Design erfordert weder Software noch Konfiguration. Dank Auto-Negotiation und Auto MDI\/MDIX k\u00f6nnen kompatible Ethernet-Ger\u00e4te automatisch verbunden werden.<\/p>\n<p data-start=\"4392\" data-end=\"4580\">Ein l\u00fcfterloses Metallgeh\u00e4use sorgt f\u00fcr einen ger\u00e4uschlosen Betrieb und passive W\u00e4rmeableitung, wodurch sich der Switch f\u00fcr HomeLab, NAS, kleine B\u00fcros, Desktop-Umgebungen und andere ger\u00e4uschempfindliche Umgebungen eignet.<\/p>\n<p data-start=\"4392\" data-end=\"4580\">\n<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1aclfck\" data-start=\"5021\" data-end=\"5037\">Wesentliche Merkmale<\/h1>\n<ul data-start=\"5039\" data-end=\"5474\">\n<li data-section-id=\"18sjqt9\" data-start=\"5039\" data-end=\"5082\">Acht Multi-Gigabit-2.5GBASE-T-RJ45-Anschl\u00fcsse<\/li>\n<li data-section-id=\"19drwit\" data-start=\"5083\" data-end=\"5109\">Ein 10G-SFP+-Uplink-Steckplatz<\/li>\n<li data-section-id=\"106pzn2\" data-start=\"5110\" data-end=\"5137\">60 Gbit\/s Switching-Kapazit\u00e4t<\/li>\n<li data-section-id=\"juqlm3\" data-start=\"5138\" data-end=\"5172\">44,64 Mpps Paketweiterleitungsrate<\/li>\n<li data-section-id=\"ilcl2o\" data-start=\"5173\" data-end=\"5207\">Blockierungsfreies Switching mit Leitungsgeschwindigkeit<\/li>\n<li data-section-id=\"gwe1w0\" data-start=\"5208\" data-end=\"5230\">4K-MAC-Adressentabelle<\/li>\n<li data-section-id=\"pc3jle\" data-start=\"5231\" data-end=\"5263\">Store-and-Forward-Architektur<\/li>\n<li data-section-id=\"66cdft\" data-start=\"5264\" data-end=\"5282\">Automatische Aushandlung<\/li>\n<li data-section-id=\"kgd768\" data-start=\"5283\" data-end=\"5298\">Auto-MDI\/MDIX<\/li>\n<li data-section-id=\"19v9b9w\" data-start=\"5299\" data-end=\"5321\">Unterst\u00fctzung von IEEE 802.3bz<\/li>\n<li data-section-id=\"r6j2h0\" data-start=\"5322\" data-end=\"5350\">L\u00fcfterlose Metallkonstruktion<\/li>\n<li data-section-id=\"fgxvlu\" data-start=\"5351\" data-end=\"5386\">Plug-and-Play-Betrieb ohne Verwaltung<\/li>\n<li data-section-id=\"nrmoxn\" data-start=\"5387\" data-end=\"5424\">Netzwerkerweiterung f\u00fcr Desktop-PCs mit geringem Stromverbrauch<\/li>\n<li data-section-id=\"lgrjij\" data-start=\"5425\" data-end=\"5474\">Geeignet f\u00fcr NAS-, WLAN-6\/7- und HomeLab-Netzwerke<\/li>\n<\/ul>\n<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1aclfck\" data-start=\"5021\" data-end=\"5037\">Anwendungen<\/h1>\n<ul>\n<li data-section-id=\"gcsz87\" data-start=\"5624\" data-end=\"5643\">2,5-G-NAS-Netzwerke<\/li>\n<li data-section-id=\"q5jwud\" data-start=\"5644\" data-end=\"5662\">HomeLab-Netzwerke<\/li>\n<li data-section-id=\"ny8tnd\" data-start=\"5663\" data-end=\"5696\">WLAN 6- und WLAN 7-Zugangspunkte<\/li>\n<li data-section-id=\"vbciow\" data-start=\"5697\" data-end=\"5721\">2,5-G-Desktop-Computer<\/li>\n<li data-section-id=\"zwpm5y\" data-start=\"5722\" data-end=\"5744\">Mini-PCs und Server<\/li>\n<li data-section-id=\"1l63hcc\" data-start=\"5745\" data-end=\"5780\">Netzwerke f\u00fcr die Hochgeschwindigkeits-Datei\u00fcbertragung<\/li>\n<li data-section-id=\"xyj5bp\" data-start=\"5781\" data-end=\"5803\">10G-Backbone-Uplinks<\/li>\n<li data-section-id=\"1n14fa2\" data-start=\"5804\" data-end=\"5827\">Kleine B\u00fcronetzwerke<\/li>\n<li data-section-id=\"543gkt\" data-start=\"5828\" data-end=\"5856\">Workstations f\u00fcr die Videobearbeitung<\/li>\n<li data-section-id=\"1p1b0t5\" data-start=\"5857\" data-end=\"5886\">Multi-Gigabit-Heimnetzwerke<\/li>\n<\/ul>\n<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1xrataf\" data-start=\"5919\" data-end=\"5947\">Technische Daten<\/h1>\n<div class=\"group TyagGW_tableContainer\">\n<div class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"5949\" data-end=\"6712\">\n<thead data-start=\"5949\" data-end=\"5978\">\n<tr data-start=\"5949\" data-end=\"5978\">\n<th class=\"last:pe-10\" data-start=\"5949\" data-end=\"5961\" data-col-size=\"sm\">Parameter<\/th>\n<th class=\"last:pe-10\" data-start=\"5961\" data-end=\"5978\" data-col-size=\"md\">Spezifikation<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"5989\" data-end=\"6712\">\n<tr data-start=\"5989\" data-end=\"6007\">\n<td data-start=\"5989\" data-end=\"5997\" data-col-size=\"sm\">Marke<\/td>\n<td data-start=\"5997\" data-end=\"6007\" data-col-size=\"md\">Luleey<\/td>\n<\/tr>\n<tr data-start=\"6008\" data-end=\"6038\">\n<td data-start=\"6008\" data-end=\"6016\" data-col-size=\"sm\">Modell<\/td>\n<td data-start=\"6016\" data-end=\"6038\" data-col-size=\"md\">LL-ESNM-825GE1SFP+<\/td>\n<\/tr>\n<tr data-start=\"6039\" data-end=\"6088\">\n<td data-start=\"6039\" data-end=\"6054\" data-col-size=\"sm\">Produkttyp<\/td>\n<td data-start=\"6054\" data-end=\"6088\" data-col-size=\"md\">Unmanaged Multi-Gigabit-Switch<\/td>\n<\/tr>\n<tr data-start=\"6089\" data-end=\"6107\">\n<td data-start=\"6089\" data-end=\"6102\" data-col-size=\"sm\">RJ45-Anschl\u00fcsse<\/td>\n<td data-start=\"6102\" data-end=\"6107\" data-col-size=\"md\">8<\/td>\n<\/tr>\n<tr data-start=\"6108\" data-end=\"6153\">\n<td data-start=\"6108\" data-end=\"6127\" data-col-size=\"sm\">RJ45-Anschlussgeschwindigkeiten<\/td>\n<td data-col-size=\"md\" data-start=\"6127\" data-end=\"6153\">10 M \/ 100 M \/ 1 G \/ 2,5 G<\/td>\n<\/tr>\n<tr data-start=\"6154\" data-end=\"6172\">\n<td data-start=\"6154\" data-end=\"6167\" data-col-size=\"sm\">SFP+-Anschl\u00fcsse<\/td>\n<td data-start=\"6167\" data-end=\"6172\" data-col-size=\"md\">1<\/td>\n<\/tr>\n<tr data-start=\"6173\" data-end=\"6201\">\n<td data-start=\"6173\" data-end=\"6191\" data-col-size=\"sm\">SFP+-Portgeschwindigkeit<\/td>\n<td data-start=\"6191\" data-end=\"6201\" data-col-size=\"md\">10Gbps<\/td>\n<\/tr>\n<tr data-start=\"6202\" data-end=\"6233\">\n<td data-start=\"6202\" data-end=\"6223\" data-col-size=\"sm\">Schaltleistung<\/td>\n<td data-col-size=\"md\" data-start=\"6223\" data-end=\"6233\">60Gbps<\/td>\n<\/tr>\n<tr data-start=\"6234\" data-end=\"6273\">\n<td data-start=\"6234\" data-end=\"6259\" data-col-size=\"sm\">Paketweiterleitungsrate<\/td>\n<td data-start=\"6259\" data-end=\"6273\" data-col-size=\"md\">44,64 Mpps<\/td>\n<\/tr>\n<tr data-start=\"6274\" data-end=\"6300\">\n<td data-start=\"6274\" data-end=\"6294\" data-col-size=\"sm\">MAC-Adressentabelle<\/td>\n<td data-start=\"6294\" data-end=\"6300\" data-col-size=\"md\">4K<\/td>\n<\/tr>\n<tr data-start=\"6301\" data-end=\"6342\">\n<td data-start=\"6301\" data-end=\"6321\" data-col-size=\"sm\">Weiterleitungsmethode<\/td>\n<td data-start=\"6321\" data-end=\"6342\" data-col-size=\"md\">Speichern und Weiterleiten<\/td>\n<\/tr>\n<tr data-start=\"6343\" data-end=\"6412\">\n<td data-start=\"6343\" data-end=\"6364\" data-col-size=\"sm\">Ethernet-Standards<\/td>\n<td data-col-size=\"md\" data-start=\"6364\" data-end=\"6412\">IEEE 802.3, 802.3u, 802.3x, 802.3ab, 802.3bz<\/td>\n<\/tr>\n<tr data-start=\"6413\" data-end=\"6445\">\n<td data-start=\"6413\" data-end=\"6432\" data-col-size=\"sm\">Automatische Aushandlung<\/td>\n<td data-start=\"6432\" data-end=\"6445\" data-col-size=\"md\">Unterst\u00fctzt<\/td>\n<\/tr>\n<tr data-start=\"6446\" data-end=\"6475\">\n<td data-start=\"6446\" data-end=\"6462\" data-col-size=\"sm\">Auto-MDI\/MDIX<\/td>\n<td data-start=\"6462\" data-end=\"6475\" data-col-size=\"md\">Unterst\u00fctzt<\/td>\n<\/tr>\n<tr data-start=\"6476\" data-end=\"6521\">\n<td data-start=\"6476\" data-end=\"6507\" data-col-size=\"sm\">\u00dcbertragungsreichweite bei Kupferkabeln<\/td>\n<td data-col-size=\"md\" data-start=\"6507\" data-end=\"6521\">Bis zu 100 m<\/td>\n<\/tr>\n<tr data-start=\"6522\" data-end=\"6543\">\n<td data-start=\"6522\" data-end=\"6532\" data-col-size=\"sm\">K\u00fchlung<\/td>\n<td data-start=\"6532\" data-end=\"6543\" data-col-size=\"md\">L\u00fcfterlos<\/td>\n<\/tr>\n<tr data-start=\"6544\" data-end=\"6586\">\n<td data-start=\"6544\" data-end=\"6568\" data-col-size=\"sm\">Betriebstemperatur<\/td>\n<td data-start=\"6568\" data-end=\"6586\" data-col-size=\"md\">-10 \u00b0C bis +55 \u00b0C<\/td>\n<\/tr>\n<tr data-start=\"6587\" data-end=\"6627\">\n<td data-start=\"6587\" data-end=\"6609\" data-col-size=\"sm\">Lagertemperatur<\/td>\n<td data-start=\"6609\" data-end=\"6627\" data-col-size=\"md\">-40 \u00b0C bis +85 \u00b0C<\/td>\n<\/tr>\n<tr data-start=\"6628\" data-end=\"6657\">\n<td data-start=\"6628\" data-end=\"6642\" data-col-size=\"sm\">Leistungsaufnahme<\/td>\n<td data-start=\"6642\" data-end=\"6657\" data-col-size=\"md\">100\u2013240 V Wechselstrom<\/td>\n<\/tr>\n<tr data-start=\"6658\" data-end=\"6684\">\n<td data-start=\"6658\" data-end=\"6671\" data-col-size=\"sm\">Verwaltung<\/td>\n<td data-col-size=\"md\" data-start=\"6671\" data-end=\"6684\">Unverwaltet<\/td>\n<\/tr>\n<tr data-start=\"6685\" data-end=\"6712\">\n<td data-start=\"6685\" data-end=\"6691\" data-col-size=\"sm\">PoE<\/td>\n<td data-start=\"6691\" data-end=\"6712\" data-col-size=\"md\"><strong data-start=\"6693\" data-end=\"6710\">Nicht unterst\u00fctzt<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"2910\" data-end=\"3066\">Der Luleey <strong data-start=\"2921\" data-end=\"2952\">8-Port-2,5-G-Ethernet-Switch<\/strong> vereint acht Multi-Gigabit-RJ45-Ports mit einem 10G-SFP+-Uplink f\u00fcr NAS, Server, WLAN 6\/7 und HomeLab-Netzwerke.<\/p>\n<ul data-start=\"3068\" data-end=\"3438\">\n<li data-section-id=\"1d3jjhe\" data-start=\"3068\" data-end=\"3109\">8 \u00d7 10 M\/100 M\/1 G\/2,5 G RJ45-Ethernet-Anschl\u00fcsse<\/li>\n<li data-section-id=\"dijo6y\" data-start=\"3110\" data-end=\"3135\">1\u00d7 10G-SFP+-Uplink-Anschluss<\/li>\n<li data-section-id=\"106pzn2\" data-start=\"3136\" data-end=\"3163\">60 Gbit\/s Switching-Kapazit\u00e4t<\/li>\n<li data-section-id=\"juqlm3\" data-start=\"3164\" data-end=\"3198\">44,64 Mpps Paketweiterleitungsrate<\/li>\n<li data-section-id=\"17488yh\" data-start=\"3199\" data-end=\"3234\">Blockierungsfreie Weiterleitung mit Leitungsgeschwindigkeit<\/li>\n<li data-section-id=\"fgxvlu\" data-start=\"3235\" data-end=\"3270\">Plug-and-Play-Betrieb ohne Verwaltung<\/li>\n<li data-section-id=\"nay1ei\" data-start=\"3271\" data-end=\"3307\">Automatische Erkennung und Auto-MDI\/MDIX<\/li>\n<li data-section-id=\"apk21r\" data-start=\"3308\" data-end=\"3352\">L\u00fcfterloses Metallgeh\u00e4use f\u00fcr ger\u00e4uschlosen Betrieb<\/li>\n<li data-section-id=\"gwe1w0\" data-start=\"3353\" data-end=\"3375\">4K-MAC-Adressentabelle<\/li>\n<li data-section-id=\"1gxhukz\" data-start=\"3376\" data-end=\"3438\">Geeignet f\u00fcr NAS, Server, WLAN-6\/7-Zugangspunkte und HomeLab-Netzwerke<\/li>\n<\/ul>","protected":false},"featured_media":21910,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[356],"product_tag":[1438,124,125,173,1441,208,1440,1439,322],"class_list":["post-12816","product","type-product","status-publish","has-post-thumbnail","product_cat-unmanaged-switches","product_tag-10g-sfp-switch","product_tag-2-5g","product_tag-2-5g-ethernet-switch","product_tag-8-port","product_tag-8-port-2-5g-switch","product_tag-ethernet-switch","product_tag-fanless-network-switch","product_tag-multi-gigabit-switch","product_tag-sfp","first","instock","shipping-taxable","purchasable","product-type-variable","has-default-attributes"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product\/12816","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/comments?post=12816"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/media\/21910"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/media?parent=12816"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product_brand?post=12816"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product_cat?post=12816"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product_tag?post=12816"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}