{"id":21491,"date":"2026-07-28T10:04:50","date_gmt":"2026-07-28T02:04:50","guid":{"rendered":"https:\/\/www.luleey.com\/?post_type=product&#038;p=21491"},"modified":"2026-07-28T12:20:22","modified_gmt":"2026-07-28T04:20:22","slug":"1x2-plc-splitter-0-9mm-mini-module-sc-upc-single-mode","status":"publish","type":"product","link":"https:\/\/www.luleey.com\/de\/produkt-2\/1x2-plc-splitter-0-9mm-mini-module-sc-upc-single-mode\/","title":{"rendered":"1\u00d72-PLC-Splitter, 0,9 mm Mini-Modul, SC\/UPC-Einmoden"},"content":{"rendered":"<h2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1crby37\" data-start=\"2260\" data-end=\"2288\">\u00dcbersicht \u00fcber den 1\u00d72-PLC-Splitter<\/h2>\n<p data-start=\"2290\" data-end=\"2438\">Die <strong data-start=\"2294\" data-end=\"2314\">1\u00d72-SPS-Splitter<\/strong> ist ein passives optisches Bauteil, das dazu dient, ein eingehendes Single-Mode-Lichtsignal gleichm\u00e4\u00dfig auf zwei Ausgangsfasern aufzuteilen.<\/p>\n<p data-start=\"2440\" data-end=\"2704\">Basierend auf der Technologie der planaren Lichtwellenleiter-Schaltungen sorgt sie f\u00fcr eine stabile optische Leistungsverteilung im Verh\u00e4ltnis 50:50 \u00fcber einen breiten Betriebswellenl\u00e4ngenbereich von 1260 bis 1650 nm. Die 1\u00d72-Konfiguration erm\u00f6glicht es, dass eine Zuf\u00fchrfaser zwei optische Abzweige versorgt, ohne dass eine aktive Schaltvorrichtung erforderlich ist.<\/p>\n<p data-start=\"2706\" data-end=\"2961\">Dieses Modell verwendet eine 0,9 mm starke Singlemode-G.657A-Faser sowie SC\/UPC-Stecker. Die kompakte Mini-Modul-Bauweise eignet sich f\u00fcr den Einbau in Glasfaserverteilerk\u00e4sten, Wandgeh\u00e4use, Splei\u00dfk\u00e4sten, Ger\u00e4teschr\u00e4nke und Laborpr\u00fcfsysteme.<\/p>\n<p data-start=\"2963\" data-end=\"3202\">Mit einem Einf\u00fcged\u00e4mpfungswert der Klasse P von \u22644,0 dB, einer Gleichm\u00e4\u00dfigkeit von \u22640,4 dB und einer polarisationsabh\u00e4ngigen D\u00e4mpfung von \u22640,2 dB gew\u00e4hrleistet der Splitter eine stabile passive optische Signalverteilung f\u00fcr FTTH-, GPON-, EPON-, FTTB-, passive optische LAN- und Telekommunikationsnetze.<\/p>\n<h2 data-section-id=\"1ma7m6t\" data-start=\"3204\" data-end=\"3219\">Wesentliche Merkmale<\/h2>\n<ul data-start=\"3221\" data-end=\"3677\">\n<li data-section-id=\"1tc8eo9\" data-start=\"3221\" data-end=\"3261\">Standardkonfiguration mit gleichm\u00e4\u00dfiger Aufteilung 1\u00d72<\/li>\n<li data-section-id=\"hvpsi9\" data-start=\"3262\" data-end=\"3305\">Ein optischer Eingang und zwei optische Ausg\u00e4nge<\/li>\n<li data-section-id=\"1v00de5\" data-start=\"3306\" data-end=\"3333\">Optisches Aufteilungsverh\u00e4ltnis 50:50<\/li>\n<li data-section-id=\"1vc027r\" data-start=\"3334\" data-end=\"3360\">G.657A-Einmodenfaser<\/li>\n<li data-section-id=\"tvwq4g\" data-start=\"3361\" data-end=\"3390\">0,9 mm gesch\u00fctzte Glasfaserleitungen<\/li>\n<li data-section-id=\"5n1xom\" data-start=\"3391\" data-end=\"3421\">Anschluss von SC\/UPC-Steckern<\/li>\n<li data-section-id=\"1f3o7y3\" data-start=\"3422\" data-end=\"3456\">Betriebswellenl\u00e4nge 1260\u20131650 nm<\/li>\n<li data-section-id=\"1fk0xtl\" data-start=\"3457\" data-end=\"3488\">Einf\u00fcgungsd\u00e4mpfung der Klasse P \u2264 4,0 dB<\/li>\n<li data-section-id=\"mlwk3c\" data-start=\"3489\" data-end=\"3520\">Einf\u00fcgungsd\u00e4mpfung der Klasse S \u2264 4,2 dB<\/li>\n<li data-section-id=\"wazojn\" data-start=\"3521\" data-end=\"3545\">Verlustgleichm\u00e4\u00dfigkeit \u2264 0,4 dB<\/li>\n<li data-section-id=\"1wimhvu\" data-start=\"3546\" data-end=\"3582\">Polarisationsabh\u00e4ngiger Verlust \u2264 0,2 dB<\/li>\n<li data-section-id=\"m224ea\" data-start=\"3583\" data-end=\"3602\">R\u00fcckflussd\u00e4mpfung \u2265 55 dB<\/li>\n<li data-section-id=\"1wok30d\" data-start=\"3603\" data-end=\"3622\">Richtwirkung \u2265 55 dB<\/li>\n<li data-section-id=\"1fsxu0s\" data-start=\"3623\" data-end=\"3648\">Vollst\u00e4ndig passiver Betrieb<\/li>\n<li data-section-id=\"1gno8gy\" data-start=\"3649\" data-end=\"3677\">Keine externe Stromversorgung erforderlich<\/li>\n<\/ul>\n<h2 data-section-id=\"mu966k\" data-start=\"3679\" data-end=\"3694\">Anwendungen<\/h2>\n<ul data-start=\"3696\" data-end=\"3963\">\n<li data-section-id=\"1run9es\" data-start=\"3696\" data-end=\"3720\">FTTH- und FTTB-Netze<\/li>\n<li data-section-id=\"1mugjd4\" data-start=\"3721\" data-end=\"3752\">GPON- und EPON-Zugangsnetze<\/li>\n<li data-section-id=\"1yijt5u\" data-start=\"3753\" data-end=\"3779\">Passive optische Netzwerke<\/li>\n<li data-section-id=\"b4fu59\" data-start=\"3780\" data-end=\"3808\">Optische Verteilerk\u00e4sten<\/li>\n<li data-section-id=\"13aq180\" data-start=\"3809\" data-end=\"3832\">Glasfasersplei\u00dfgeh\u00e4use<\/li>\n<li data-section-id=\"18ias1d\" data-start=\"3833\" data-end=\"3863\">Telekommunikations\u00fcbertragungssysteme<\/li>\n<li data-section-id=\"1alg9rg\" data-start=\"3864\" data-end=\"3885\">Passives optisches LAN<\/li>\n<li data-section-id=\"ogb3cm\" data-start=\"3886\" data-end=\"3913\">\u00dcberwachung optischer Signale<\/li>\n<li data-section-id=\"1fe3hus\" data-start=\"3914\" data-end=\"3934\">Pr\u00fcfung von Glasfaserverbindungen<\/li>\n<li data-section-id=\"1h8f95d\" data-start=\"3935\" data-end=\"3963\">Optische Laborsysteme<\/li>\n<\/ul>\n<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"54pib2\" data-start=\"4026\" data-end=\"4054\">Technische Daten<\/h1>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"4056\" data-end=\"4672\">\n<thead data-start=\"4056\" data-end=\"4085\">\n<tr data-start=\"4056\" data-end=\"4085\">\n<th class=\"last:pe-10\" data-start=\"4056\" data-end=\"4068\" data-col-size=\"sm\">Parameter<\/th>\n<th class=\"last:pe-10\" data-start=\"4068\" data-end=\"4085\" data-col-size=\"sm\">Spezifikation<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"4096\" data-end=\"4672\">\n<tr data-start=\"4096\" data-end=\"4114\">\n<td data-start=\"4096\" data-end=\"4104\" data-col-size=\"sm\">Marke<\/td>\n<td data-start=\"4104\" data-end=\"4114\" data-col-size=\"sm\">Luleey<\/td>\n<\/tr>\n<tr data-start=\"4115\" data-end=\"4152\">\n<td data-start=\"4115\" data-end=\"4130\" data-col-size=\"sm\">Produkttyp<\/td>\n<td data-start=\"4130\" data-end=\"4152\" data-col-size=\"sm\">PLC-Fasersplitter<\/td>\n<\/tr>\n<tr data-start=\"4153\" data-end=\"4198\">\n<td data-start=\"4153\" data-end=\"4175\" data-col-size=\"sm\">Geteilte Konfiguration<\/td>\n<td data-start=\"4175\" data-end=\"4198\" data-col-size=\"sm\">1 Eingang \u00d7 2 Ausg\u00e4nge<\/td>\n<\/tr>\n<tr data-start=\"4199\" data-end=\"4222\">\n<td data-start=\"4199\" data-end=\"4213\" data-col-size=\"sm\">Teilungsverh\u00e4ltnis<\/td>\n<td data-start=\"4213\" data-end=\"4222\" data-col-size=\"sm\">50:50<\/td>\n<\/tr>\n<tr data-start=\"4223\" data-end=\"4250\">\n<td data-start=\"4223\" data-end=\"4240\" data-col-size=\"sm\">Stecker Typ<\/td>\n<td data-start=\"4240\" data-end=\"4250\" data-col-size=\"sm\">SC\/UPC<\/td>\n<\/tr>\n<tr data-start=\"4251\" data-end=\"4279\">\n<td data-start=\"4251\" data-end=\"4264\" data-col-size=\"sm\">Glasfasermodus<\/td>\n<td data-start=\"4264\" data-end=\"4279\" data-col-size=\"sm\">Einzelner Modus<\/td>\n<\/tr>\n<tr data-start=\"4280\" data-end=\"4309\">\n<td data-start=\"4280\" data-end=\"4293\" data-col-size=\"sm\">Faser-Typ<\/td>\n<td data-start=\"4293\" data-end=\"4309\" data-col-size=\"sm\">ITU-T G.657A<\/td>\n<\/tr>\n<tr data-start=\"4310\" data-end=\"4336\">\n<td data-start=\"4310\" data-end=\"4327\" data-col-size=\"sm\">Faserdurchmesser<\/td>\n<td data-col-size=\"sm\" data-start=\"4327\" data-end=\"4336\">0,9 mm<\/td>\n<\/tr>\n<tr data-start=\"4337\" data-end=\"4375\">\n<td data-start=\"4337\" data-end=\"4360\" data-col-size=\"sm\">Betriebswellenl\u00e4nge<\/td>\n<td data-col-size=\"sm\" data-start=\"4360\" data-end=\"4375\">1260\u20131650 nm<\/td>\n<\/tr>\n<tr data-start=\"4376\" data-end=\"4411\">\n<td data-start=\"4376\" data-end=\"4401\" data-col-size=\"sm\">Einf\u00fcgungsd\u00e4mpfung der Klasse P<\/td>\n<td data-start=\"4401\" data-end=\"4411\" data-col-size=\"sm\">\u2264 4,0 dB<\/td>\n<\/tr>\n<tr data-start=\"4412\" data-end=\"4447\">\n<td data-start=\"4412\" data-end=\"4437\" data-col-size=\"sm\">Einf\u00fcgungsd\u00e4mpfung der Klasse S<\/td>\n<td data-start=\"4437\" data-end=\"4447\" data-col-size=\"sm\">\u2264 4,2 dB<\/td>\n<\/tr>\n<tr data-start=\"4448\" data-end=\"4476\">\n<td data-start=\"4448\" data-end=\"4466\" data-col-size=\"sm\">Verlustgleichm\u00e4\u00dfigkeit<\/td>\n<td data-start=\"4466\" data-end=\"4476\" data-col-size=\"sm\">\u2264 0,4 dB<\/td>\n<\/tr>\n<tr data-start=\"4477\" data-end=\"4517\">\n<td data-start=\"4477\" data-end=\"4507\" data-col-size=\"sm\">Polarisationsabh\u00e4ngiger Verlust<\/td>\n<td data-start=\"4507\" data-end=\"4517\" data-col-size=\"sm\">\u22640,2dB<\/td>\n<\/tr>\n<tr data-start=\"4518\" data-end=\"4541\">\n<td data-start=\"4518\" data-end=\"4532\" data-col-size=\"sm\">R\u00fcckflussd\u00e4mpfung<\/td>\n<td data-start=\"4532\" data-end=\"4541\" data-col-size=\"sm\">\u226555dB<\/td>\n<\/tr>\n<tr data-start=\"4542\" data-end=\"4565\">\n<td data-start=\"4542\" data-end=\"4556\" data-col-size=\"sm\">Richtwirkung<\/td>\n<td data-start=\"4556\" data-end=\"4565\" data-col-size=\"sm\">\u226555dB<\/td>\n<\/tr>\n<tr data-start=\"4566\" data-end=\"4608\">\n<td data-start=\"4566\" data-end=\"4590\" data-col-size=\"sm\">Betriebstemperatur<\/td>\n<td data-start=\"4590\" data-end=\"4608\" data-col-size=\"sm\">-40 \u00b0C bis +85 \u00b0C<\/td>\n<\/tr>\n<tr data-start=\"4609\" data-end=\"4639\">\n<td data-start=\"4609\" data-end=\"4633\" data-col-size=\"sm\">Standardfaserl\u00e4nge<\/td>\n<td data-start=\"4633\" data-end=\"4639\" data-col-size=\"sm\">1m<\/td>\n<\/tr>\n<tr data-start=\"4640\" data-end=\"4672\">\n<td data-start=\"4640\" data-end=\"4666\" data-col-size=\"sm\">Externe Stromversorgung erforderlich<\/td>\n<td data-start=\"4666\" data-end=\"4672\" data-col-size=\"sm\">Nein<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"w33md\" data-start=\"4707\" data-end=\"4723\">Wie es funktioniert<\/h1>\n<p data-start=\"4725\" data-end=\"4844\">Das eingehende optische Signal wird \u00fcber einen SC\/UPC-Eingang eingeleitet und gleichm\u00e4\u00dfig auf zwei SC\/UPC-Ausgangsfasern verteilt.<\/p>\n<p data-start=\"4846\" data-end=\"5028\">Der Splitter arbeitet passiv und ben\u00f6tigt keine externe Stromversorgung. Jeder Ausgang erh\u00e4lt etwa die H\u00e4lfte der optischen Eingangsleistung, bevor die Einf\u00fcgungsd\u00e4mpfung des Splitters ber\u00fccksichtigt wird.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"1719\" data-end=\"1865\">Der Luleey <strong data-start=\"1730\" data-end=\"1750\">1\u00d72-SPS-Splitter<\/strong> teilt einen optischen Single-Mode-Eingang im Wellenl\u00e4ngenbereich von 1260\u20131650 nm gleichm\u00e4\u00dfig auf zwei SC\/UPC-Ausg\u00e4nge f\u00fcr FTTH- und PON-Netzwerke auf.<\/p>\n<ul data-start=\"1867\" data-end=\"2190\">\n<li data-section-id=\"duu53e\" data-start=\"1867\" data-end=\"1903\">1 Eingang zu 2 identischen optischen Ausg\u00e4ngen<\/li>\n<li data-section-id=\"5n1xom\" data-start=\"1904\" data-end=\"1934\">Anschluss von SC\/UPC-Steckern<\/li>\n<li data-section-id=\"12sum1c\" data-start=\"1935\" data-end=\"1967\">0,9 mm Single-Mode-G.657A-Faser<\/li>\n<li data-section-id=\"kr5mse\" data-start=\"1968\" data-end=\"2008\">Breiter Wellenl\u00e4ngenbereich: 1260\u20131650 nm<\/li>\n<li data-section-id=\"1fk0xtl\" data-start=\"2009\" data-end=\"2040\">Einf\u00fcgungsd\u00e4mpfung der Klasse P \u2264 4,0 dB<\/li>\n<li data-section-id=\"1gs829g\" data-start=\"2041\" data-end=\"2064\">Geringe Gleichm\u00e4\u00dfigkeit \u2264 0,4 dB<\/li>\n<li data-section-id=\"6dspa6\" data-start=\"2065\" data-end=\"2105\">Geringer polarisationsabh\u00e4ngiger Verlust \u2264 0,2 dB<\/li>\n<li data-section-id=\"1jwqsyn\" data-start=\"2106\" data-end=\"2141\">R\u00fcckflussd\u00e4mpfung und Richtwirkung \u2265 55 dB<\/li>\n<li data-section-id=\"1iy5vpu\" data-start=\"2142\" data-end=\"2190\">Vollst\u00e4ndig passiver Betrieb ohne externe Stromversorgung<\/li>\n<\/ul>","protected":false},"featured_media":12990,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[366],"product_tag":[118,1348,1350,1351,288,1352,326],"class_list":["post-21491","product","type-product","status-publish","has-post-thumbnail","product_cat-optical-splitters-and-splitter-box","product_tag-1x2","product_tag-1x2-plc-splitter","product_tag-fiber-optic-splitter","product_tag-ftth-splitter","product_tag-plc-splitter","product_tag-sc-upc-splitter","product_tag-splitter","first","instock","shipping-taxable","purchasable","product-type-variable","has-default-attributes"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product\/21491","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/comments?post=21491"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/media\/12990"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/media?parent=21491"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product_brand?post=21491"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product_cat?post=21491"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product_tag?post=21491"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}