{"id":21497,"date":"2026-07-28T10:35:55","date_gmt":"2026-07-28T02:35:55","guid":{"rendered":"https:\/\/www.luleey.com\/?post_type=product&#038;p=21497"},"modified":"2026-07-28T12:20:42","modified_gmt":"2026-07-28T04:20:42","slug":"1x4-plc-splitter-0-9mm-mini-module-sc-upc-single-mode","status":"publish","type":"product","link":"https:\/\/www.luleey.com\/de\/produkt-2\/1x4-plc-splitter-0-9mm-mini-module-sc-upc-single-mode\/","title":{"rendered":"1\u00d74-PLC-Splitter, 0,9 mm Mini-Modul, SC\/UPC-Einmoden"},"content":{"rendered":"<h2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1495ln9\" data-start=\"2174\" data-end=\"2202\">\u00dcbersicht \u00fcber den 1\u00d74-PLC-Splitter<\/h2>\n<p data-start=\"2204\" data-end=\"2353\">Die <strong data-start=\"2208\" data-end=\"2228\">1\u00d74-PLC-Splitter<\/strong> ist ein passives optisches Bauteil, das dazu dient, ein eingehendes Single-Mode-Lichtsignal gleichm\u00e4\u00dfig auf vier Ausgangsfasern aufzuteilen.<\/p>\n<p data-start=\"2355\" data-end=\"2642\">Basierend auf der Technologie der planaren Lichtwellenleiter-Schaltungen sorgt er f\u00fcr eine stabile optische Leistungsverteilung im Verh\u00e4ltnis 25:25:25:25 \u00fcber den Betriebswellenl\u00e4ngenbereich von 1260\u20131650 nm. Der Splitter erm\u00f6glicht es, dass eine Zuf\u00fchrfaser vier optische Abzweige versorgt, ohne dass eine aktive Schaltvorrichtung oder eine externe Stromversorgung erforderlich ist.<\/p>\n<p data-start=\"2644\" data-end=\"2974\">Dieses Modell verwendet eine 0,9 mm starke Singlemode-G.657A-Faser sowie SC\/UPC-Stecker. Die SC\/UPC-Schnittstellen erm\u00f6glichen verlustarme Verbindungen f\u00fcr standardm\u00e4\u00dfige Singlemode-Glasfasernetzwerke, w\u00e4hrend sich die kompakte Mini-Modul-Bauweise f\u00fcr den Einbau in Glasfaserverteilerk\u00e4sten, Splei\u00dfk\u00e4sten, Wandgeh\u00e4use und Ger\u00e4teschr\u00e4nke eignet.<\/p>\n<p data-start=\"2976\" data-end=\"3244\">Mit einem Einf\u00fcged\u00e4mpfungswert der Klasse P von \u22647,4 dB, einer D\u00e4mpfungsgleichm\u00e4\u00dfigkeit von \u22640,6 dB und einer polarisationsabh\u00e4ngigen D\u00e4mpfung von \u22640,3 dB gew\u00e4hrleistet der Splitter eine stabile passive Signalverteilung f\u00fcr FTTH-, GPON-, EPON-, FTTB- und passive optische LAN-Anwendungen sowie f\u00fcr Telekommunikations\u00fcbertragungs- und optische \u00dcberwachungssysteme.<\/p>\n<h2 data-section-id=\"1ma7m6t\" data-start=\"3246\" data-end=\"3261\">Wesentliche Merkmale<\/h2>\n<ul data-start=\"3263\" data-end=\"3694\">\n<li data-section-id=\"j366hb\" data-start=\"3263\" data-end=\"3303\">Standardkonfiguration mit gleichm\u00e4\u00dfiger Aufteilung im Verh\u00e4ltnis 1:4<\/li>\n<li data-section-id=\"1ss087n\" data-start=\"3304\" data-end=\"3348\">Ein optischer Eingang und vier optische Ausg\u00e4nge<\/li>\n<li data-section-id=\"lnqtnx\" data-start=\"3349\" data-end=\"3382\">25:25:25:25 optisches Aufteilungsverh\u00e4ltnis<\/li>\n<li data-section-id=\"1vc027r\" data-start=\"3383\" data-end=\"3409\">G.657A-Einmodenfaser<\/li>\n<li data-section-id=\"tvwq4g\" data-start=\"3410\" data-end=\"3439\">0,9 mm gesch\u00fctzte Glasfaserleitungen<\/li>\n<li data-section-id=\"5n1xom\" data-start=\"3440\" data-end=\"3470\">Anschluss von SC\/UPC-Steckern<\/li>\n<li data-section-id=\"1f3o7y3\" data-start=\"3471\" data-end=\"3505\">Betriebswellenl\u00e4nge 1260\u20131650 nm<\/li>\n<li data-section-id=\"1fm0mda\" data-start=\"3506\" data-end=\"3537\">Einf\u00fcgungsd\u00e4mpfung der Klasse P \u2264 7,4 dB<\/li>\n<li data-section-id=\"wazthd\" data-start=\"3538\" data-end=\"3562\">D\u00e4mpfungsgleichm\u00e4\u00dfigkeit \u2264 0,6 dB<\/li>\n<li data-section-id=\"1wimh3f\" data-start=\"3563\" data-end=\"3599\">Polarisationsabh\u00e4ngiger Verlust \u2264 0,3 dB<\/li>\n<li data-section-id=\"m224ea\" data-start=\"3600\" data-end=\"3619\">R\u00fcckflussd\u00e4mpfung \u2265 55 dB<\/li>\n<li data-section-id=\"1wok30d\" data-start=\"3620\" data-end=\"3639\">Richtwirkung \u2265 55 dB<\/li>\n<li data-section-id=\"1fsxu0s\" data-start=\"3640\" data-end=\"3665\">Vollst\u00e4ndig passiver Betrieb<\/li>\n<li data-section-id=\"1gno8gy\" data-start=\"3666\" data-end=\"3694\">Keine externe Stromversorgung erforderlich<\/li>\n<\/ul>\n<h2 data-section-id=\"mu966k\" data-start=\"3696\" data-end=\"3711\">Anwendungen<\/h2>\n<ul data-start=\"3713\" data-end=\"3978\">\n<li data-section-id=\"1run9es\" data-start=\"3713\" data-end=\"3737\">FTTH- und FTTB-Netze<\/li>\n<li data-section-id=\"1mugjd4\" data-start=\"3738\" data-end=\"3769\">GPON- und EPON-Zugangsnetze<\/li>\n<li data-section-id=\"1yijt5u\" data-start=\"3770\" data-end=\"3796\">Passive optische Netzwerke<\/li>\n<li data-section-id=\"1tyizpn\" data-start=\"3797\" data-end=\"3823\">Glasfaser-Verteilerk\u00e4sten<\/li>\n<li data-section-id=\"13aq180\" data-start=\"3824\" data-end=\"3847\">Glasfasersplei\u00dfgeh\u00e4use<\/li>\n<li data-section-id=\"18ias1d\" data-start=\"3848\" data-end=\"3878\">Telekommunikations\u00fcbertragungssysteme<\/li>\n<li data-section-id=\"1alg9rg\" data-start=\"3879\" data-end=\"3900\">Passives optisches LAN<\/li>\n<li data-section-id=\"ogb3cm\" data-start=\"3901\" data-end=\"3928\">\u00dcberwachung optischer Signale<\/li>\n<li data-section-id=\"1fe3hus\" data-start=\"3929\" data-end=\"3949\">Pr\u00fcfung von Glasfaserverbindungen<\/li>\n<li data-section-id=\"1h8f95d\" data-start=\"3950\" data-end=\"3978\">Optische Laborsysteme<\/li>\n<\/ul>\n<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"54pib2\" data-start=\"4104\" data-end=\"4132\">Technische Daten<\/h1>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"4134\" data-end=\"4751\">\n<thead data-start=\"4134\" data-end=\"4163\">\n<tr data-start=\"4134\" data-end=\"4163\">\n<th class=\"last:pe-10\" data-start=\"4134\" data-end=\"4146\" data-col-size=\"sm\">Parameter<\/th>\n<th class=\"last:pe-10\" data-start=\"4146\" data-end=\"4163\" data-col-size=\"sm\">Spezifikation<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"4174\" data-end=\"4751\">\n<tr data-start=\"4174\" data-end=\"4192\">\n<td data-start=\"4174\" data-end=\"4182\" data-col-size=\"sm\">Marke<\/td>\n<td data-start=\"4182\" data-end=\"4192\" data-col-size=\"sm\">Luleey<\/td>\n<\/tr>\n<tr data-start=\"4193\" data-end=\"4230\">\n<td data-start=\"4193\" data-end=\"4208\" data-col-size=\"sm\">Produkttyp<\/td>\n<td data-start=\"4208\" data-end=\"4230\" data-col-size=\"sm\">PLC-Fasersplitter<\/td>\n<\/tr>\n<tr data-start=\"4231\" data-end=\"4276\">\n<td data-start=\"4231\" data-end=\"4253\" data-col-size=\"sm\">Geteilte Konfiguration<\/td>\n<td data-start=\"4253\" data-end=\"4276\" data-col-size=\"sm\">1 Eingang \u00d7 4 Ausg\u00e4nge<\/td>\n<\/tr>\n<tr data-start=\"4277\" data-end=\"4306\">\n<td data-start=\"4277\" data-end=\"4291\" data-col-size=\"sm\">Teilungsverh\u00e4ltnis<\/td>\n<td data-start=\"4291\" data-end=\"4306\" data-col-size=\"sm\">25:25:25:25<\/td>\n<\/tr>\n<tr data-start=\"4307\" data-end=\"4334\">\n<td data-start=\"4307\" data-end=\"4324\" data-col-size=\"sm\">Stecker Typ<\/td>\n<td data-start=\"4324\" data-end=\"4334\" data-col-size=\"sm\">SC\/UPC<\/td>\n<\/tr>\n<tr data-start=\"4335\" data-end=\"4365\">\n<td data-start=\"4335\" data-end=\"4350\" data-col-size=\"sm\">Paket Typ<\/td>\n<td data-start=\"4350\" data-end=\"4365\" data-col-size=\"sm\">Mini-Modul<\/td>\n<\/tr>\n<tr data-start=\"4366\" data-end=\"4394\">\n<td data-start=\"4366\" data-end=\"4379\" data-col-size=\"sm\">Glasfasermodus<\/td>\n<td data-start=\"4379\" data-end=\"4394\" data-col-size=\"sm\">Einzelner Modus<\/td>\n<\/tr>\n<tr data-start=\"4395\" data-end=\"4424\">\n<td data-start=\"4395\" data-end=\"4408\" data-col-size=\"sm\">Faser-Typ<\/td>\n<td data-start=\"4408\" data-end=\"4424\" data-col-size=\"sm\">ITU-T G.657A<\/td>\n<\/tr>\n<tr data-start=\"4425\" data-end=\"4451\">\n<td data-start=\"4425\" data-end=\"4442\" data-col-size=\"sm\">Faserdurchmesser<\/td>\n<td data-start=\"4442\" data-end=\"4451\" data-col-size=\"sm\">0,9 mm<\/td>\n<\/tr>\n<tr data-start=\"4452\" data-end=\"4490\">\n<td data-start=\"4452\" data-end=\"4475\" data-col-size=\"sm\">Betriebswellenl\u00e4nge<\/td>\n<td data-start=\"4475\" data-end=\"4490\" data-col-size=\"sm\">1260\u20131650 nm<\/td>\n<\/tr>\n<tr data-start=\"4491\" data-end=\"4526\">\n<td data-start=\"4491\" data-end=\"4516\" data-col-size=\"sm\">Einf\u00fcgungsd\u00e4mpfung der Klasse P<\/td>\n<td data-start=\"4516\" data-end=\"4526\" data-col-size=\"sm\">\u22647,4 dB<\/td>\n<\/tr>\n<tr data-start=\"4527\" data-end=\"4555\">\n<td data-start=\"4527\" data-end=\"4545\" data-col-size=\"sm\">Verlustgleichm\u00e4\u00dfigkeit<\/td>\n<td data-start=\"4545\" data-end=\"4555\" data-col-size=\"sm\">\u2264 0,6 dB<\/td>\n<\/tr>\n<tr data-start=\"4556\" data-end=\"4596\">\n<td data-start=\"4556\" data-end=\"4586\" data-col-size=\"sm\">Polarisationsabh\u00e4ngiger Verlust<\/td>\n<td data-start=\"4586\" data-end=\"4596\" data-col-size=\"sm\">\u22640,3dB<\/td>\n<\/tr>\n<tr data-start=\"4597\" data-end=\"4620\">\n<td data-start=\"4597\" data-end=\"4611\" data-col-size=\"sm\">R\u00fcckflussd\u00e4mpfung<\/td>\n<td data-start=\"4611\" data-end=\"4620\" data-col-size=\"sm\">\u226555dB<\/td>\n<\/tr>\n<tr data-start=\"4621\" data-end=\"4644\">\n<td data-start=\"4621\" data-end=\"4635\" data-col-size=\"sm\">Richtwirkung<\/td>\n<td data-start=\"4635\" data-end=\"4644\" data-col-size=\"sm\">\u226555dB<\/td>\n<\/tr>\n<tr data-start=\"4645\" data-end=\"4687\">\n<td data-start=\"4645\" data-end=\"4669\" data-col-size=\"sm\">Betriebstemperatur<\/td>\n<td data-start=\"4669\" data-end=\"4687\" data-col-size=\"sm\">-40 \u00b0C bis +85 \u00b0C<\/td>\n<\/tr>\n<tr data-start=\"4688\" data-end=\"4718\">\n<td data-start=\"4688\" data-end=\"4712\" data-col-size=\"sm\">Standardfaserl\u00e4nge<\/td>\n<td data-start=\"4712\" data-end=\"4718\" data-col-size=\"sm\">1m<\/td>\n<\/tr>\n<tr data-start=\"4719\" data-end=\"4751\">\n<td data-start=\"4719\" data-end=\"4745\" data-col-size=\"sm\">Externe Stromversorgung erforderlich<\/td>\n<td data-start=\"4745\" data-end=\"4751\" data-col-size=\"sm\">Nein<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"w33md\" data-start=\"4945\" data-end=\"4961\">Wie es funktioniert<\/h1>\n<p data-start=\"4963\" data-end=\"5083\">Das eingehende optische Signal wird \u00fcber einen SC\/UPC-Eingang eingespeist und gleichm\u00e4\u00dfig auf vier SC\/UPC-Ausgangsfasern verteilt.<\/p>\n<p data-start=\"5085\" data-end=\"5268\">Der Splitter arbeitet passiv und ben\u00f6tigt keine elektrische Energie. Jeder Ausgang erh\u00e4lt etwa 25% der optischen Eingangsleistung, bevor die Einf\u00fcgungsd\u00e4mpfung des Splitters ber\u00fccksichtigt wird.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"1535\" data-end=\"1682\">Der Luleey <strong data-start=\"1546\" data-end=\"1566\">1\u00d74-PLC-Splitter<\/strong> teilt einen optischen Single-Mode-Eingang im Wellenl\u00e4ngenbereich von 1260\u20131650 nm gleichm\u00e4\u00dfig auf vier SC\/UPC-Ausg\u00e4nge auf \u2013 f\u00fcr FTTH- und PON-Netzwerke.<\/p>\n<ul data-start=\"1684\" data-end=\"2036\">\n<li data-section-id=\"1wsigng\" data-start=\"1684\" data-end=\"1720\">1 Eingang auf 4 identische optische Ausg\u00e4nge<\/li>\n<li data-section-id=\"5n1xom\" data-start=\"1721\" data-end=\"1751\">Anschluss von SC\/UPC-Steckern<\/li>\n<li data-section-id=\"1gm3nzv\" data-start=\"1752\" data-end=\"1786\">Single-Mode-Glasfaser nach G.657A<\/li>\n<li data-section-id=\"tvwq4g\" data-start=\"1787\" data-end=\"1816\">0,9 mm gesch\u00fctzte Glasfaserleitungen<\/li>\n<li data-section-id=\"kr5mse\" data-start=\"1817\" data-end=\"1857\">Breiter Wellenl\u00e4ngenbereich: 1260\u20131650 nm<\/li>\n<li data-section-id=\"1fm0mda\" data-start=\"1858\" data-end=\"1889\">Einf\u00fcgungsd\u00e4mpfung der Klasse P \u2264 7,4 dB<\/li>\n<li data-section-id=\"wazthd\" data-start=\"1890\" data-end=\"1914\">D\u00e4mpfungsgleichm\u00e4\u00dfigkeit \u2264 0,6 dB<\/li>\n<li data-section-id=\"1wimh3f\" data-start=\"1915\" data-end=\"1951\">Polarisationsabh\u00e4ngiger Verlust \u2264 0,3 dB<\/li>\n<li data-section-id=\"1jwqsyn\" data-start=\"1952\" data-end=\"1987\">R\u00fcckflussd\u00e4mpfung und Richtwirkung \u2265 55 dB<\/li>\n<li data-section-id=\"1iy5vpu\" data-start=\"1988\" data-end=\"2036\">Vollst\u00e4ndig passiver Betrieb ohne externe Stromversorgung<\/li>\n<\/ul>","protected":false},"featured_media":12964,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[366],"product_tag":[120,1355,1350,1351,288,1352,326],"class_list":["post-21497","product","type-product","status-publish","has-post-thumbnail","product_cat-optical-splitters-and-splitter-box","product_tag-1x4","product_tag-1x4-plc-splitter","product_tag-fiber-optic-splitter","product_tag-ftth-splitter","product_tag-plc-splitter","product_tag-sc-upc-splitter","product_tag-splitter","first","instock","shipping-taxable","purchasable","product-type-variable","has-default-attributes"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product\/21497","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/comments?post=21497"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/media\/12964"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/media?parent=21497"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product_brand?post=21497"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product_cat?post=21497"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/de\/wp-json\/wp\/v2\/product_tag?post=21497"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}