{"id":22311,"date":"2026-09-21T11:16:16","date_gmt":"2026-09-21T03:16:16","guid":{"rendered":"https:\/\/www.luleey.com\/?p=22311"},"modified":"2026-09-20T11:20:47","modified_gmt":"2026-09-20T03:20:47","slug":"how-to-test-an-sfp-port-with-a-fiber-loopback","status":"publish","type":"post","link":"https:\/\/www.luleey.com\/es\/how-to-test-an-sfp-port-with-a-fiber-loopback\/","title":{"rendered":"C\u00f3mo comprobar un puerto SFP con un bucle de retorno de fibra \u00f3ptica"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-9d78ff3e\">A <strong>probar un <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/es\/tag\/sfp\/\" title=\"Ver todos los puestos en SPP\">SFP<\/a> puerto con un <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/es\/tag\/fiber-loopback\/\" title=\"Ver todas las entradas de \u00abFiber Loopback\u00bb\">Bucle de retorno de fibra \u00f3ptica<\/a><\/strong>, vuelve a conectar el transmisor \u00f3ptico al receptor a trav\u00e9s de una ruta de fibra pasiva correctamente adaptada. El resultado puede ayudar a aislar el puerto del host local, el transceptor y la ruta del conector de la red de fibra remota y del dispositivo hom\u00f3logo.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-acbb8b30\">Se trata de una comprobaci\u00f3n diagn\u00f3stica limitada, no de una certificaci\u00f3n completa de la conexi\u00f3n. Una prueba de bucle cerrado que elimine la p\u00e9rdida de se\u00f1al (LOS) o restablezca la interfaz no garantiza el buen estado del cable remoto, del dispositivo del extremo opuesto, de la configuraci\u00f3n de la VLAN ni de la interoperabilidad en entorno de producci\u00f3n. Antes de conectar cualquier dispositivo, comprueba tambi\u00e9n que la potencia \u00f3ptica de retorno no supere la entrada m\u00e1xima de funcionamiento del receptor.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-c6fd394d\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22313\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/test-sfp-port-fiber-loopback-hero.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/test-sfp-port-fiber-loopback-hero.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/test-sfp-port-fiber-loopback-hero-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/test-sfp-port-fiber-loopback-hero-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/test-sfp-port-fiber-loopback-hero-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/test-sfp-port-fiber-loopback-hero-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/test-sfp-port-fiber-loopback-hero-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-dede1808\">Comprobaci\u00f3n de un puerto SFP con un bucle de retorno de fibra: qu\u00e9 abarca<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-012700e3\">Un transceptor \u00f3ptico d\u00faplex tiene un lado de transmisi\u00f3n y un lado de recepci\u00f3n. Un bucle de retorno pasivo d\u00faplex redirige:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e60db6ed\"><strong>TX local \u2192 ruta corta de fibra \u2192 RX local<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6844dc07\">Dependiendo del host, el PHY, el PMD de Ethernet y la configuraci\u00f3n del puerto, el dispositivo puede borrar el indicador \u00abRX LOS\u00bb, notificar que el receptor est\u00e1 sincronizado o mostrar el estado \u00abLink Up\u00bb. Algunas plataformas requieren un modo de diagn\u00f3stico espec\u00edfico o un segundo puerto, por lo que no se garantiza que se muestre el estado \u00abLink Up\u00bb para todos los bucles \u00f3pticos locales v\u00e1lidos.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f287cb85\">La prueba puede poner a prueba estos elementos locales en las siguientes condiciones de prueba:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>La capacidad del host para reconocer y alimentar el m\u00f3dulo<\/li>\n\n\n\n<li>El transmisor y el receptor \u00f3pticos del m\u00f3dulo<\/li>\n\n\n\n<li>El conector de bucle cerrado y el trayecto corto de la fibra<\/li>\n\n\n\n<li>Es suficiente con la ruta el\u00e9ctrica\/SerDes del host para generar el estado observado<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8f53a1d3\">S\u00ed que lo hace <strong>no<\/strong> comprobar el tronco de producci\u00f3n, los paneles de conexi\u00f3n, los empalmes, el transceptor remoto o el host remoto. Tampoco genera ni verifica autom\u00e1ticamente tr\u00e1fico Ethernet \u00fatil. Es posible que un conmutador no env\u00ede una trama por un puerto y acepte la misma trama de vuelta, como ocurre en una prueba normal de extremo a extremo. Las pruebas de paquetes requieren un diagn\u00f3stico compatible con la plataforma, un generador de tr\u00e1fico o un m\u00e9todo de prueba documentado.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-6719bf2a\">1. Asigna el bucle de retorno a la interfaz \u00f3ptica exacta<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5e634b87\">Empieza por el n\u00famero de referencia del transceptor y su ficha t\u00e9cnica. Haz coincidir el conector, el pulido y el tipo de fibra del bucle de retorno con el PMD \u00f3ptico, y no solo con el formato met\u00e1lico del m\u00f3dulo.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e7724fdb\">Por ejemplo, un m\u00f3dulo \u00f3ptico d\u00faplex 10GBASE-SR t\u00edpico utiliza fibra multimodo, mientras que un m\u00f3dulo \u00f3ptico d\u00faplex 10GBASE-LR t\u00edpico utiliza fibra monomodo. La norma IEEE 802.3 define diferentes especificaciones de medio f\u00edsico para las distintas velocidades y medios de Ethernet; la <a href=\"https:\/\/ieeexplore.ieee.org\/document\/9844436\" target=\"_blank\" rel=\"noopener\">Ficha t\u00e9cnica de la norma IEEE 802.3-2022<\/a> Es la referencia normativa, pero son los documentos espec\u00edficos del host y del m\u00f3dulo los que determinan qu\u00e9 es lo que admite tu hardware.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2060bef8\">Marca todas las opciones siguientes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Modelo del host, n\u00famero de puerto y modos el\u00e9ctricos\/SerDes compatibles<\/li>\n\n\n\n<li>N\u00famero de referencia del m\u00f3dulo, revisi\u00f3n, codificaci\u00f3n y PMD \u00f3ptico<\/li>\n\n\n\n<li>Tasa real configurada o negociada<\/li>\n\n\n\n<li>Tipo de fibra, conector y pulido<\/li>\n\n\n\n<li>Cualquier configuraci\u00f3n necesaria de FEC, negociaci\u00f3n autom\u00e1tica o modo de puerto<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-230dcae2\">Un SFP, <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/es\/tag\/sfp-2\/\" title=\"Ver todos los puestos en SFP+\">SFP<\/a> Ni la etiqueta SFP28 ni ninguna otra resuelven estas cuestiones. La compatibilidad f\u00edsica, la compatibilidad con el equipo host, el modo de funcionamiento, la velocidad de enlace y el rendimiento del tr\u00e1fico \u00fatil son aspectos independientes.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-4a230470\">No utilices un bucle de retorno pasivo normal para una prueba BiDi.<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6cb08dd8\">Un par BiDi de fibra \u00fanica habitual utiliza longitudes de onda complementarias para la transmisi\u00f3n y la recepci\u00f3n. Un m\u00f3dulo puede transmitir en una longitud de onda y esperar recibir una longitud de onda diferente en su receptor. Un bucle de fibra pasivo solo devuelve la longitud de onda transmitida; no la convierte.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-77800a71\">Por lo tanto, es posible que no se establezca ninguna conexi\u00f3n, incluso cuando el m\u00f3dulo BiDi funcione correctamente. Utiliza un dispositivo compatible o una configuraci\u00f3n de prueba que tenga en cuenta la longitud de onda.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-f6ecaf2a\">2. Comprueba la alimentaci\u00f3n del receptor antes de realizar un bucle corto<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d841db02\">Esta es la comprobaci\u00f3n de seguridad m\u00e1s importante para los sistemas \u00f3pticos de largo alcance. Un enlace de producci\u00f3n puede incluir kil\u00f3metros de fibra y varios decibelios de p\u00e9rdida. Un bucle de retorno corto elimina la mayor parte de esa p\u00e9rdida y puede devolver demasiada potencia al receptor.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8fc4c68c\">Utiliza la ficha t\u00e9cnica exacta del m\u00f3dulo y calcula el nivel de recepci\u00f3n m\u00e1ximo previsto:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6cd63786\"><strong>potencia m\u00e1xima de transmisi\u00f3n \u2212 p\u00e9rdida m\u00ednima en la ruta de retorno = potencia m\u00e1xima esperada de recepci\u00f3n<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b78ca695\">El resultado no debe superar el del receptor <strong>potencia m\u00e1xima de entrada en funcionamiento<\/strong> para ese modo. Incluye las tolerancias de cualquier conector, bucle de retroalimentaci\u00f3n y atenuador. No sustituyas la entrada m\u00e1xima de funcionamiento por un umbral de da\u00f1o; responden a cuestiones diferentes.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-aeaf3289\">Si en la ficha t\u00e9cnica no se indica el l\u00edmite del receptor superior, detente y solic\u00edtalo. Si se requiere atenuaci\u00f3n, utiliza un bucle de retorno atenuado o un atenuador \u00f3ptico correctamente especificado. No provoques p\u00e9rdidas doblando excesivamente un cable de conexi\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6e7f7bc1\">Una vez establecida la conexi\u00f3n, <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/es\/tag\/ddm\/\" title=\"Ver todas las entradas en DDM\">DDM<\/a> puede servir como una verificaci\u00f3n cruzada \u00fatil cuando tanto el m\u00f3dulo como el host lo exponen. <a href=\"https:\/\/members.snia.org\/document\/dl\/25916\" target=\"_blank\" rel=\"noopener\">SFF-8472<\/a> Define los campos correspondientes a la temperatura, la tensi\u00f3n de alimentaci\u00f3n, la polarizaci\u00f3n de transmisi\u00f3n, la potencia de transmisi\u00f3n y la potencia de recepci\u00f3n, y distingue la potencia media recibida de los datos que proporciona OMA. La precisi\u00f3n y los umbrales del DDM siguen dependiendo del m\u00f3dulo; compara la lectura con los l\u00edmites de funcionamiento exactos.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9bb9f6bb\">LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/es\/what-is-ddm-dom-in-sfp-transceivers\/\">Gu\u00eda de campo de DDM\/DOM<\/a> explica los cinco valores comunes, mientras que el <a href=\"https:\/\/www.luleey.com\/es\/sfp-receiver-overload-can-optical-power-be-too-high\/\">Gu\u00eda sobre la sobrecarga del receptor<\/a> trata la comprobaci\u00f3n del l\u00edmite superior con m\u00e1s detalle.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-42ecff89\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22312\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/safe-sfp-loopback-test-flow.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/safe-sfp-loopback-test-flow.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/safe-sfp-loopback-test-flow-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/safe-sfp-loopback-test-flow-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/safe-sfp-loopback-test-flow-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/safe-sfp-loopback-test-flow-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/safe-sfp-loopback-test-flow-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-d72e2a62\">3. Ejecuta la prueba de bucle local<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d2565199\">Utiliza una franja horaria de mantenimiento autorizada. La desconexi\u00f3n de una ruta de producci\u00f3n interrumpe el servicio.<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Registra el valor de referencia.<\/strong> Guarda el modelo del host, la configuraci\u00f3n de los puertos, la identidad del m\u00f3dulo, el firmware y los controladores, el estado actual del enlace y de la conexi\u00f3n (LOS), las lecturas del DDM y los contadores de errores.<\/li>\n\n\n\n<li><strong>Comprueba la combinaci\u00f3n prevista.<\/strong> Confirma el PMD, la potencia, la categor\u00eda de fibra, el conector\/pulido y el nivel de recepci\u00f3n seguro. No sigas adelante bas\u00e1ndote \u00fanicamente en el ajuste del conector.<\/li>\n\n\n\n<li><strong>Revisar y limpiar.<\/strong> Inspecciona la interfaz de bucle cerrado y la interfaz del transceptor con equipos homologados, y l\u00edmpialas cuando sea necesario. La <a href=\"https:\/\/foa.org\/tech\/ref\/testing\/test\/scope.html\" target=\"_blank\" rel=\"noopener\">Gu\u00eda de conectores de la Asociaci\u00f3n de Fibra \u00d3ptica<\/a> explica c\u00f3mo se puede transmitir la contaminaci\u00f3n entre los casquillos acoplados. Nunca mires directamente hacia el interior de una fibra o un puerto \u00f3ptico; utiliza un medidor de potencia adecuado y un m\u00e9todo de inspecci\u00f3n por v\u00eddeo.<\/li>\n\n\n\n<li><strong>Introduce el loopback correcto.<\/strong> Conecta el TX local al RX local sin forzar ni torcer el conector. Activa el modo de puerto previsto siguiendo el procedimiento del host.<\/li>\n\n\n\n<li><strong>Observa el estado y las variaciones.<\/strong> Comprueba la presencia del m\u00f3dulo, los fallos de transmisi\u00f3n (TX), la p\u00e9rdida de se\u00f1al de recepci\u00f3n (RX LOS), el estado del enlace\/PCS, la potencia de recepci\u00f3n (DDM RX), los eventos de enlace y los cambios en el contador de nuevos errores. Registra una comparaci\u00f3n cronometrada del antes y el despu\u00e9s.<\/li>\n\n\n\n<li><strong>Utiliza el tr\u00e1fico solo si est\u00e1 disponible.<\/strong> Si la plataforma ofrece una prueba de diagn\u00f3stico del puerto o de tr\u00e1fico documentada, sigue ese procedimiento al pie de la letra. No des por sentado que un ping dirigido al propio dispositivo pasa por el puerto f\u00edsico.<\/li>\n\n\n\n<li><strong>Eliminar y restaurar.<\/strong> Desactive o a\u00edsle el puerto seg\u00fan sea necesario, elimine el bucle de retorno, proteja y limpie las interfaces, restablezca la configuraci\u00f3n aprobada y compruebe que el servicio funciona con normalidad.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-f16ced4b\">4. Interpretar el resultado sin exagerar<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Observaci\u00f3n<\/th><th>Qu\u00e9 es compatible<\/th><th>Siguiente comprobaci\u00f3n \u00fatil<\/th><\/tr><\/thead><tbody><tr><td>No se ha detectado el m\u00f3dulo<\/td><td>El host no puede leer ni aceptar el m\u00f3dulo en la configuraci\u00f3n actual<\/td><td>Comprueba la jaula, la alimentaci\u00f3n, la codificaci\u00f3n, la lista de m\u00f3dulos compatibles, el firmware y el modo de puerto<\/td><\/tr><tr><td>Se ha detectado el m\u00f3dulo, pero la se\u00f1al RX LOS sigue activa<\/td><td>El receptor local no capta una se\u00f1al adecuada.<\/td><td>Comprobar la activaci\u00f3n\/fallo de la transmisi\u00f3n, la coincidencia de la fibra y el pulido, la conexi\u00f3n del bucle de retorno, el comportamiento de la longitud de onda y la potencia \u00f3ptica<\/td><\/tr><tr><td>Se borra el LOS o el enlace se restablece con contadores estables<\/td><td>La trayectoria \u00f3ptica local sometida a ensayo funciona en esas condiciones<\/td><td>Avanzar hacia el cable de conexi\u00f3n del entorno de producci\u00f3n, los paneles, el tronco y el nodo remoto<\/td><\/tr><tr><td>El enlace aparece, pero aumentan los errores<\/td><td>La presencia de se\u00f1al no equivale a una transmisi\u00f3n de fotogramas sin interferencias<\/td><td>Comprueba los l\u00edmites de potencia, la contaminaci\u00f3n, los ajustes de PMD, la velocidad y el FEC, as\u00ed como la ruta del m\u00f3dulo local y del host.<\/td><\/tr><tr><td>Un m\u00f3dulo BiDi no se vincula a s\u00ed mismo<\/td><td>Esto puede ser normal, ya que las longitudes de onda de transmisi\u00f3n (TX) y recepci\u00f3n (RX) son diferentes.<\/td><td>Utiliza el par BiDi complementario o una configuraci\u00f3n que tenga en cuenta la longitud de onda<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a56bc152\">Un bucle local que funciona correctamente reduce el \u00e1mbito de la aver\u00eda. No garantiza el margen de temperatura, el comportamiento en cuanto a errores a largo plazo ni la compatibilidad con el dispositivo remoto. Por el contrario, un bucle que falla no es prueba inmediata de que el m\u00f3dulo est\u00e9 defectuoso: la causa puede estar en la configuraci\u00f3n de la prueba, el comportamiento del host, la configuraci\u00f3n del puerto o una potencia \u00f3ptica excesiva o insuficiente.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-da0975f5\">Si la interfaz se conecta pero aparecen errores, sigue con el procedimiento de LuLeey: <a href=\"https:\/\/www.luleey.com\/es\/sfp-crc-errors-with-normal-rx-power-what-to-check\/\">Gu\u00eda de resoluci\u00f3n de problemas del CRC del SFP<\/a> y comparar las variaciones recientes en el mostrador en lugar de un total hist\u00f3rico.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-bb1f8201\">C\u00f3mo elegir un LuLeey Loopback<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2eacb4f2\">LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/es\/producto\/fiber-optic-loopback-lc-upc-om3-mm\/\">Bucle de retorno de fibra multimodo LC\/UPC OM3<\/a> Se especifica como un cable multimodo de 50\/125 \u00b5m con una interfaz LC\/UPC y una p\u00e9rdida de inserci\u00f3n de no m\u00e1s de 0,2 dB. Estos datos no lo convierten en un cable universal.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7c2bc1e9\">El valor publicado es un <strong>p\u00e9rdida de inserci\u00f3n m\u00e1xima<\/strong>, y no una atenuaci\u00f3n m\u00ednima garantizada. Por s\u00ed sola, no puede demostrar que un bucle corto sea seguro para un par emisor-receptor desconocido. La p\u00e1gina tambi\u00e9n utiliza t\u00e9rminos generales en cuanto a la velocidad; selecciona el bucle de retroalimentaci\u00f3n en funci\u00f3n de la PMD exacta, la disposici\u00f3n de los carriles, los l\u00edmites del m\u00f3dulo y el comportamiento del host, en lugar de basarte \u00fanicamente en el nombre de la familia de SFP o en la velocidad nominal.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-14893bfa\"><strong>Pr\u00f3ximo paso:<\/strong> Env\u00eda a LuLeey el modelo y el puerto del host, el n\u00famero de referencia y la revisi\u00f3n del m\u00f3dulo, el PMD \u00f3ptico, el tipo de fibra y conector, la velocidad configurada, el firmware y los l\u00edmites de funcionamiento de transmisi\u00f3n (TX) y recepci\u00f3n (RX) del m\u00f3dulo. De este modo, LuLeey podr\u00e1 confirmar el tipo de bucle de retorno adecuado y si es necesaria una atenuaci\u00f3n controlada.<\/p>","protected":false},"excerpt":{"rendered":"<p>Observaci\u00f3n: \u00bfQu\u00e9 admite? Siguiente comprobaci\u00f3n \u00fatil: No se detecta el m\u00f3dulo. El host no puede leer ni aceptar el m\u00f3dulo en<\/p>","protected":false},"author":1,"featured_media":22313,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1078],"tags":[69,444,1668,1670,1642,1669,71],"class_list":["post-22311","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-user-operation-guide","tag-sfp","tag-ddm","tag-fiber-loopback","tag-lc-loopback","tag-network-maintenance","tag-optical-troubleshooting","tag-sfp-2"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/posts\/22311","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/comments?post=22311"}],"version-history":[{"count":1,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/posts\/22311\/revisions"}],"predecessor-version":[{"id":22314,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/posts\/22311\/revisions\/22314"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/media\/22313"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/media?parent=22311"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/categories?post=22311"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/tags?post=22311"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}