{"id":22416,"date":"2026-09-28T16:49:41","date_gmt":"2026-09-28T08:49:41","guid":{"rendered":"https:\/\/www.luleey.com\/?p=22416"},"modified":"2026-09-27T16:53:54","modified_gmt":"2026-09-27T08:53:54","slug":"media-converter-vlan-passthrough-a-practical-guide","status":"publish","type":"post","link":"https:\/\/www.luleey.com\/es\/media-converter-vlan-passthrough-a-practical-guide\/","title":{"rendered":"Pasar VLAN con un convertidor de medios: una gu\u00eda pr\u00e1ctica"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-e25cd59e\"><strong><a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/es\/tag\/media-converter\/\" title=\"Ver todos los puestos en MEDIA CONVERTER\">CONVERTIDOR DE MEDIOS<\/a> <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/es\/tag\/vlan-passthrough\/\" title=\"Ver todas las entradas sobre \u00abVLAN Passthrough\u00bb\">Pasar VLAN<\/a><\/strong> es posible cuando el convertidor conserva las etiquetas de Ethernet y acepta el <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/es\/tag\/frame-size\/\" title=\"Ver todas las entradas de \u00abTama\u00f1o del marco\u00bb\">Tama\u00f1o del cuadro<\/a>. Sin embargo, los t\u00e9rminos \u201cno gestionado\u201d, \u201cGigabit\u201d o \u201c10G\u201d no garantizan que un modelo concreto cuente con esas prestaciones.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-35e9bc2a\">Por ejemplo, una conexi\u00f3n de fibra \u00f3ptica podr\u00eda transmitir correctamente una red sin etiquetar, mientras que un enlace ascendente de un conmutador etiquetado fallar\u00eda. La causa podr\u00eda ser el convertidor, pero tambi\u00e9n podr\u00eda deberse a un puerto que env\u00eda tramas sin etiquetar, a una VLAN excluida del conmutador remoto o a un l\u00edmite en el tama\u00f1o de las tramas.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c8f570d5\">A continuaci\u00f3n te explicamos c\u00f3mo distinguir entre esas posibilidades antes de comprar los herrajes de recambio.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-b126f487\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22418\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/media-converter-vlan-passthrough-hero.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/media-converter-vlan-passthrough-hero.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/media-converter-vlan-passthrough-hero-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/media-converter-vlan-passthrough-hero-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/media-converter-vlan-passthrough-hero-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/media-converter-vlan-passthrough-hero-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/media-converter-vlan-passthrough-hero-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-9416855e\">Qu\u00e9 significa realmente el \u00abVLAN Passthrough\u00bb de un convertidor de medios<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8f4c3563\">Para que la ruta sea transparente, un trama que entre con el ID de VLAN 100 debe salir con la misma etiqueta de VLAN. El cambio de cable de cobre a fibra \u00f3ptica no requiere, por s\u00ed mismo, modificar dicha etiqueta.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-772f4365\">Hay tres conceptos que se confunden con facilidad:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Capacidad<\/th><th>Para qu\u00e9 sirve<\/th><\/tr><\/thead><tbody><tr><td>Pasar VLAN<\/td><td>Mantiene una etiqueta ya existente a lo largo del recorrido de conversi\u00f3n<\/td><\/tr><tr><td>Configuraci\u00f3n de VLAN<\/td><td>Asigna, elimina, traduce o filtra etiquetas seg\u00fan la configuraci\u00f3n<\/td><\/tr><tr><td>Enrutamiento entre VLAN<\/td><td>Transfiere el tr\u00e1fico IP entre diferentes VLAN mediante una funci\u00f3n de enrutamiento<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-47349abe\">Un convertidor puede transmitir una trama etiquetada sin ofrecer un men\u00fa de configuraci\u00f3n de VLAN. Por el contrario, un dispositivo gestionado puede filtrar o modificar deliberadamente las etiquetas. El <a href=\"https:\/\/docs.kernel.org\/networking\/bridge.html?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Documentaci\u00f3n sobre el puente del n\u00facleo de Linux<\/a> Ilustra c\u00f3mo, al habilitar el filtrado de VLAN, el reenv\u00edo depende tanto de la pertenencia a una VLAN como de la direcci\u00f3n MAC de destino. Se trata de una explicaci\u00f3n \u00fatil de la distinci\u00f3n, no de una prueba sobre el hardware de un convertidor concreto. <a href=\"https:\/\/docs.kernel.org\/networking\/bridge.html?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">La documentaci\u00f3n del n\u00facleo de Linux<\/a><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c0270953\">Si la conexi\u00f3n f\u00edsica en s\u00ed es inestable, empieza por el m\u00e9todo de LuLeey <a href=\"https:\/\/www.luleey.com\/es\/fiber-media-converter-lights-on-but-no-network\/?utm_source=chatgpt.com\">Gu\u00eda de resoluci\u00f3n de problemas del convertidor de medios \u00abLights-On\u00bb<\/a> Primero.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-f14e9a28\">Comprueba el tama\u00f1o de la trama, no solo \u201cMTU 1500\u201d<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-29178ec3\">Un sencillo <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/es\/tag\/802-1q\/\" title=\"Ver todas las entradas sobre 802.1Q\">802.1Q<\/a> La etiqueta VLAN a\u00f1ade cuatro bytes a una trama de Ethernet. Con una carga \u00fatil de Ethernet de 1.500 bytes, los tama\u00f1os resultantes son:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Etiquetado<\/th><th>Longitud de la trama Ethernet<\/th><\/tr><\/thead><tbody><tr><td>Sin etiqueta VLAN<\/td><td>1518 bytes<\/td><\/tr><tr><td>Una etiqueta VLAN<\/td><td>1522 bytes<\/td><\/tr><tr><td>Dos etiquetas de VLAN, como, por ejemplo, <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/es\/tag\/qinq\/\" title=\"Ver todas las entradas de QinQ\">QinQ<\/a><\/td><td>1526 bytes<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ef841d3f\">Estas cifras incluyen la cabecera Ethernet y el FCS de cuatro bytes. No incluyen el pre\u00e1mbulo, el delimitador de inicio de trama ni el intervalo entre paquetes. La cifra con dos etiquetas es 1518 + 4 + 4; se parte de la base de que la carga \u00fatil sigue siendo de 1500 bytes y de que no se a\u00f1ade ninguna encapsulaci\u00f3n adicional.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e60012a0\">En <a href=\"https:\/\/wiki.wireshark.org\/Ethernet?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Referencia de Ethernet en Wireshark<\/a> describe los campos del marco base y la etiqueta VLAN de cuatro bytes. La tabla aplica esos campos a la misma carga \u00fatil de 1.500 bytes. <a href=\"https:\/\/wiki.wireshark.org\/Ethernet?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Wiki de Wireshark<\/a><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d3fcbb22\">Una especificaci\u00f3n que solo indique \u201cMTU 1500\u201d resulta ambigua a menos que se defina qu\u00e9 es lo que se cuenta. Pregunta cu\u00e1l es el tama\u00f1o m\u00e1ximo de trama Ethernet aceptado y si esa cifra incluye las etiquetas y el FCS. El hecho de que se admita una etiqueta tampoco garantiza la compatibilidad con QinQ: comprueba por separado los tipos de etiqueta, el comportamiento de las etiquetas apiladas y el tama\u00f1o de trama requerido.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-28952318\">Comprueba qu\u00e9 env\u00edan los dos puertos de los extremos<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5fb4a472\">Anota el ID de la VLAN e indica si el tr\u00e1fico debe ir etiquetado o sin etiquetar en cada conexi\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ffb6aeb8\">Para una extensi\u00f3n sencilla de la VLAN 100 entre dos conmutadores gestionados, ambos puertos conectados a la ruta del convertidor transparente deben transmitir la VLAN 100 etiquetada. Los dispositivos conectados a los puertos de acceso pueden seguir enviando tr\u00e1fico normal sin etiquetar; sus conmutadores se encargan de gestionar las etiquetas en el enlace ascendente.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e8f91dad\">Comprueba la configuraci\u00f3n real, en lugar de fiarte \u00fanicamente del t\u00e9rmino \u201ctrunk\u201d:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00bfEst\u00e1 permitida la VLAN requerida en ambos enlaces ascendentes?<\/li>\n\n\n\n<li>\u00bfAlg\u00fan puerto env\u00eda esa VLAN sin etiquetar como su VLAN nativa?<\/li>\n\n\n\n<li>\u00bfQu\u00e9 VLAN recibe el tr\u00e1fico de entrada sin etiquetar: el PVID del puerto?<\/li>\n\n\n\n<li>\u00bfHay alg\u00fan dispositivo gestionado intermedio que filtre o traduzca las etiquetas?<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-84b55b3f\">Este ejemplo comprueba la conservaci\u00f3n de etiquetas. No es necesario habilitar todas las VLAN en un enlace ascendente de producci\u00f3n.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-669827e0\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22417\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/vlan-ethernet-frame-size.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/vlan-ethernet-frame-size.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/vlan-ethernet-frame-size-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/vlan-ethernet-frame-size-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/vlan-ethernet-frame-size-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/vlan-ethernet-frame-size-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/vlan-ethernet-frame-size-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-508769de\">Una prueba pr\u00e1ctica para el \u00abpassthrough\u00bb de VLAN<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e7352f59\">Utiliza una red de pruebas aislada o un intervalo de mantenimiento acordado. Guarda primero la configuraci\u00f3n actual.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-bf3c04c4\">1. Establecer una referencia que se sepa que funciona<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-17dcf3ac\">Utiliza dos conmutadores compatibles con VLAN y un ordenador de prueba conectado a cada uno de ellos. Asigna los puertos de acceso que dan al ordenador a la VLAN 100 y configura los puertos entre conmutadores para que transporten la VLAN 100 etiquetada. Asigna a los ordenadores direcciones adecuadas y \u00fanicas dentro de la misma subred de prueba.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-39c2f37b\">Comprueba la comunicaci\u00f3n a trav\u00e9s de una conexi\u00f3n directa que sepas que funciona correctamente. A continuaci\u00f3n, desconecta esa conexi\u00f3n e inserta la ruta correspondiente de convertidor y fibra entre los mismos puertos del conmutador. Mant\u00e9n sin cambios la configuraci\u00f3n de la VLAN y los ordenadores de prueba. No dejes ambas rutas conectadas, ya que podr\u00edas crear un bucle de forma accidental.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d0bae6dd\">Registra las velocidades de funcionamiento tras la sustituci\u00f3n. En el caso de los convertidores enchufables, el ajuste f\u00edsico, el modo SerDes del host, la velocidad configurada o negociada y el rendimiento \u00fatil son comprobaciones independientes. Confirma el convertidor y el m\u00f3dulo exactos, el chipset o PHY del host, el firmware o el controlador, la configuraci\u00f3n de los puertos y la codificaci\u00f3n del m\u00f3dulo.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-3c572847\">2. Realiza pruebas en ambas direcciones y con m\u00e1s de un tama\u00f1o de paquete<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5e5a2840\">Empieza con un tr\u00e1fico reducido y, a continuaci\u00f3n, comprueba cu\u00e1l es el tama\u00f1o m\u00e1ximo de paquete que requiere el servicio. Un ping predeterminado que se realiza con \u00e9xito solo supone una comprobaci\u00f3n con paquetes peque\u00f1os.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-37161ac8\">En el ejemplo de una sola etiqueta con una carga \u00fatil de 1.500 bytes, comprueba que la prueba genere realmente tramas Ethernet de 1.522 bytes, incluido el FCS. El \u201ctama\u00f1o del paquete\u201d de una herramienta puede referirse a la longitud de la direcci\u00f3n IP o a la carga \u00fatil de la prueba; tambi\u00e9n puede fragmentar el tr\u00e1fico. Comprueba la convenci\u00f3n de tama\u00f1o de la herramienta y aseg\u00farate de que la fragmentaci\u00f3n no est\u00e9 ocultando el l\u00edmite.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8708f3aa\">Repite la operaci\u00f3n en ambas direcciones. Registra las tramas de prueba transmitidas y recibidas, las p\u00e9rdidas y los cambios en el contador de errores. Si el servicio utiliza QinQ o cargas \u00fatiles mayores, a\u00f1ade esos casos concretos por separado.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-1b39310f\">3. Comprobar las etiquetas en los puntos de medici\u00f3n<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4a31fb6b\">Captura el flujo de prueba antes y despu\u00e9s de la ruta de conversi\u00f3n utilizando tomas adecuadas o puertos de duplicaci\u00f3n de conmutador. Comprueba que la configuraci\u00f3n de duplicaci\u00f3n conserve las etiquetas y que el adaptador de captura las muestre.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-899d7ac8\">En <a href=\"https:\/\/wiki.wireshark.org\/CaptureSetup\/VLAN?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Gu\u00eda para la captura de VLAN con Wireshark<\/a> explica por qu\u00e9 el sistema operativo, la interfaz de captura, la tarjeta de red o el controlador pueden ocultar etiquetas. Comprueba la configuraci\u00f3n de la captura con un flujo etiquetado conocido antes de culpar al convertidor por la falta de una etiqueta. Las capturas tambi\u00e9n pueden omitir el FCS, por lo que la longitud mostrada puede ser cuatro bytes inferior a la de la tabla anterior. <a href=\"https:\/\/wiki.wireshark.org\/CaptureSetup\/VLAN?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Wiki de Wireshark<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-d5d867cc\">4. Interpretar el resultado<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Observaci\u00f3n controlada<\/th><th>Siguiente comprobaci\u00f3n<\/th><\/tr><\/thead><tbody><tr><td>La ruta de referencia funciona; la ruta del convertidor falla incluso con tramas etiquetadas peque\u00f1as<\/td><td>Vuelve a comprobar el etiquetado de los puntos finales, el reenv\u00edo del convertidor y la ruta f\u00edsica<\/td><\/tr><tr><td>El tr\u00e1fico sin etiquetar funciona; el tr\u00e1fico etiquetado falla en una comparaci\u00f3n controlada<\/td><td>Comprueba que se mantengan las etiquetas y que se aplique el filtrado de VLAN en cada l\u00edmite<\/td><\/tr><tr><td>Los marcos peque\u00f1os etiquetados funcionan; los m\u00e1s grandes fallan<\/td><td>Analizar los l\u00edmites del tama\u00f1o de los fotogramas, el dimensionamiento de las herramientas de prueba y la fragmentaci\u00f3n<\/td><\/tr><tr><td>Se reciben las mismas etiquetas, pero falla el DHCP o el acceso a Internet<\/td><td>Comprueba la ruta de retorno, la disponibilidad de DHCP y de los servicios, el enrutamiento y la pol\u00edtica del cortafuegos.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c0c747e8\">Estos resultados limitan el alcance de la investigaci\u00f3n; ninguno de ellos por s\u00ed solo permite identificar un convertidor defectuoso. Un \u00abping\u00bb o una prueba de velocidad de Internet tampoco garantizan el correcto funcionamiento de todas las VLAN, tama\u00f1os de trama o protocolos de control.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-2eb10e77\">Qu\u00e9 hay que comprobar antes de realizar un pedido<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-17b4c6e1\">LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/es\/categoria-producto\/fiber-optic-transceiver\/copper-to-fiber-media-converters\/?utm_source=chatgpt.com\">Gama de convertidores de medios de cobre a fibra \u00f3ptica<\/a> es un punto de partida para elegir la conexi\u00f3n f\u00edsica.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0f418b03\">Por ejemplo, el <a href=\"https:\/\/www.luleey.com\/es\/producto\/ll-sfpmc10grtl-10g-sfp-to-rj45-media-convertersupport-xgs-pon-epon-stick\/?utm_source=chatgpt.com\">P\u00e1gina del producto LL-SFPMC10GRTL<\/a> menciona un chip RTL8261C, un puerto SFP+ de 10G\/2,5G y un puerto RJ45 multivelocidad. La p\u00e1gina no indica el tama\u00f1o m\u00e1ximo de trama Ethernet ni ofrece una matriz de pruebas de paso de VLAN\/QinQ. Esas especificaciones de interfaz por s\u00ed solas no permiten confirmar tu servicio etiquetado.<\/p>","protected":false},"excerpt":{"rendered":"<p>Funcionalidad. Qu\u00e9 hace. Paso directo de VLAN. Transmite una etiqueta existente a trav\u00e9s de la ruta de conversi\u00f3n. Configuraci\u00f3n de VLAN. Asigna, elimina, traduce o<\/p>","protected":false},"author":1,"featured_media":22418,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[887],"tags":[51,1698,1697,1696,1699,1694,1695],"class_list":["post-22416","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-data-transmission-conversion","tag-media-converter","tag-802-1q","tag-fiber-ethernet","tag-frame-size","tag-qinq","tag-vlan-passthrough","tag-vlan-troubleshooting"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/posts\/22416","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/comments?post=22416"}],"version-history":[{"count":1,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/posts\/22416\/revisions"}],"predecessor-version":[{"id":22419,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/posts\/22416\/revisions\/22419"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/media\/22418"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/media?parent=22416"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/categories?post=22416"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/tags?post=22416"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}