{"id":22489,"date":"2026-10-03T09:26:46","date_gmt":"2026-10-03T01:26:46","guid":{"rendered":"https:\/\/www.luleey.com\/?p=22489"},"modified":"2026-10-01T09:31:04","modified_gmt":"2026-10-01T01:31:04","slug":"rogue-onu-why-one-faulty-onu-disrupts-a-gpon-port","status":"publish","type":"post","link":"https:\/\/www.luleey.com\/es\/rogue-onu-why-one-faulty-onu-disrupts-a-gpon-port\/","title":{"rendered":"ONU defectuosa: por qu\u00e9 una ONU defectuosa interrumpe el funcionamiento de un puerto GPON"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-3553148d\">A <strong><a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/es\/tag\/rogue-onu\/\" title=\"Ver todas las entradas de Rogue ONU\">ONU rebelde<\/a><\/strong> puede provocar algo m\u00e1s que la p\u00e9rdida de su propio servicio. Si transmite luz en sentido ascendente fuera del intervalo de tiempo asignado por el <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/es\/tag\/olt\/\" title=\"Ver todos los puestos en OLT\">OLT<\/a>, puede interferir con las r\u00e1fagas de otras ONU de la misma <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/es\/tag\/gpon\/\" title=\"Ver todos los puestos en GPON\">GPON<\/a> puerto. El resultado puede parecer un fallo en la l\u00ednea de alimentaci\u00f3n: varios clientes se desconectan, oscilan entre distintos estados o no se registran al mismo tiempo.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-24a0b5b5\">La clave est\u00e1 en comprobar el patr\u00f3n de puerto compartido antes de sustituir el equipo. Una ONU que est\u00e1 desconectada no significa autom\u00e1ticamente que sea una unidad no autorizada, y la ONU que sigue apareciendo como conectada podr\u00eda incluso ser la que presenta el fallo.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-1f455a1a\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22491\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/rogue-onu-gpon-port-hero.avif\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/rogue-onu-gpon-port-hero.avif 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/rogue-onu-gpon-port-hero-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/rogue-onu-gpon-port-hero-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/rogue-onu-gpon-port-hero-768x768.avif 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/rogue-onu-gpon-port-hero-12x12.avif 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/rogue-onu-gpon-port-hero-150x150.avif 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-25b20254\">\u00bfQu\u00e9 es una ONU no autorizada?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-602ddbc0\">En la jerga del sector, una ONU defectuosa o <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/es\/tag\/rogue-ont\/\" title=\"Ver todas las entradas de Rogue ONT\">ONT no autorizada<\/a> es un terminal de red \u00f3ptica cuyo transmisor de salida no cumple las normas de la red PON. \u201c<a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/es\/tag\/long-light-onu\/\" title=\"Ver todas las publicaciones de Long-Light ONU\">ONU de luz continua<\/a>\u201d suele referirse al caso m\u00e1s evidente: el l\u00e1ser permanece encendido durante demasiado tiempo o de forma continua.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2b1fee17\">La definici\u00f3n m\u00e1s precisa es m\u00e1s amplia. <a href=\"https:\/\/www.itu.int\/rec\/T-REC-G.Sup49-202009-I\/en\" target=\"_blank\" rel=\"noopener\">Suplemento 49 de la serie G de la UIT-T<\/a> establece que una ONU debe transmitir a su potencia m\u00e1xima especificada \u00fanicamente en los intervalos de tiempo asignados por el OLT y mantenerse por debajo del l\u00edmite de potencia m\u00ednima en el resto de momentos. Una ONU que emita por encima de ese nivel de potencia m\u00ednima fuera de su asignaci\u00f3n se considera una unidad no autorizada.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c3a73cf7\">Eso significa que una condici\u00f3n an\u00f3mala podr\u00eda ser:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Continuo, con el transmisor encendido de forma permanente<\/li>\n\n\n\n<li>Es intermitente, por lo que el puerto solo falla en determinados momentos<\/li>\n\n\n\n<li>Una desviaci\u00f3n temporal que hace que parte de una r\u00e1faga quede fuera de su intervalo de concesi\u00f3n<\/li>\n\n\n\n<li>Una transmisi\u00f3n an\u00f3mala provocada por un fallo de software, MAC, firmware o del hardware del transmisor<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-dd26ffb2\">Se trata de un fallo en el comportamiento de la transmisi\u00f3n, no es sin\u00f3nimo de \u201cno registrado\u201d, \u201cno compatible\u201d o \u201cbaja potencia \u00f3ptica\u201d.\u201d<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-d497858e\">Por qu\u00e9 una ONU defectuosa puede afectar a todo un puerto GPON<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d5f530c7\"><a href=\"https:\/\/www.itu.int\/rec\/T-REC-G.984.3\/en\" target=\"_blank\" rel=\"noopener\">UIT-T G.984.3<\/a> especifica el acceso m\u00faltiple por divisi\u00f3n de tiempo (TDM) en sentido ascendente para GPON. El OLT asigna a cada ONU una ventana de transmisi\u00f3n. A continuaci\u00f3n, el divisor pasivo combina toda la luz en sentido ascendente en el cable de alimentaci\u00f3n compartido hacia el receptor de r\u00e1fagas del OLT.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3055a5de\">En condiciones normales de funcionamiento, las r\u00e1fagas llegan de forma secuencial:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-160bd2f0\"><code>ONU A \u2192 ONU B \u2192 ONU C \u2192 silencio \u00f3ptico \u2192 siguientes subvenciones<\/code><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3ef4fccd\">Si la ONU C emite durante la ventana de la ONU A o durante un intervalo de silencio \u00f3ptico, el OLT recibe luz superpuesta o inesperada. Es posible que no pueda recuperar la r\u00e1faga prevista. El Suplemento 49 de la UIT-T se\u00f1ala que la transmisi\u00f3n continua o fuera del intervalo de tiempo puede afectar a las comunicaciones con todas las ONU de la red PON, aunque el impacto exacto puede ser intermitente o de baja intensidad.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e6e9de52\">Esto explica un importante error que se comete a la hora de solucionar problemas: la ONU que no puede registrarse puede ser una v\u00edctima inocente. No identifiques el dispositivo no autorizado bas\u00e1ndote \u00fanicamente en cu\u00e1l es la ONU que est\u00e1 desconectada.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-e8a8f721\">S\u00edntomas de una ONU no autorizada: busca el patr\u00f3n de fallo compartido<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f2347df3\">No hay ning\u00fan s\u00edntoma por s\u00ed solo que demuestre que una ONU es defectuosa. Utiliza una combinaci\u00f3n de an\u00e1lisis con osciloscopio, tiempo de respuesta, pruebas del OLT y aislamiento controlado.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Observaci\u00f3n<\/th><th>Lo que sugiere<\/th><th>Ser\u00e1 mejor que lo compruebes la pr\u00f3xima vez<\/th><\/tr><\/thead><tbody><tr><td>Un ONU est\u00e1 desconectado; los dispositivos hom\u00f3logos conectados al mismo puerto PON siguen funcionando con normalidad<\/td><td>Es m\u00e1s probable que se trate de una ca\u00edda local, un problema de alimentaci\u00f3n, un fallo \u00f3ptico, un problema de identidad o de aprovisionamiento.<\/td><td>Comprueba primero esa ONU y descon\u00e9ctala<\/td><\/tr><tr><td>Varias ONU no relacionadas entre s\u00ed conectadas a un mismo puerto PON fallan al mismo tiempo<\/td><td>ONU no autorizada, fallo en el alimentador o divisor, fallo en el puerto OLT o problema general de alimentaci\u00f3n<\/td><td>Comparar marcas de tiempo y alarmas del OLT<\/td><\/tr><tr><td>Fallen varios puertos PON o toda una tarjeta<\/td><td>Es menos probable que haya una ONU no autorizada en una de las ramas<\/td><td>Comprueba la tarjeta de l\u00ednea, el enlace ascendente, la alimentaci\u00f3n del chasis y la configuraci\u00f3n compartida<\/td><\/tr><tr><td>El OLT notifica una potencia \u00f3ptica inesperada, errores de r\u00e1faga o una alarma de luz an\u00f3mala o prolongada<\/td><td>Es plausible que se produzca un comportamiento an\u00f3malo<\/td><td>Conserva los registros y utiliza el flujo de trabajo de detecci\u00f3n compatible con el modelo<\/td><\/tr><tr><td>Las dem\u00e1s ONU se recuperan cuando se a\u00edsla una rama del divisor<\/td><td>Hay pruebas s\u00f3lidas de que la falla se encuentra dentro de esa rama<\/td><td>Limitar la b\u00fasqueda de \u00absucursal\u00bb a \u00abONU individual\u00bb<\/td><\/tr><tr><td>Un ONU sigue en estado estable O5, pero solo ese usuario carece de direcci\u00f3n IP<\/td><td>Normalmente se trata de un problema de la capa de servicio, no de un incidente aislado relacionado con un puerto compartido.<\/td><td>Comprueba la VLAN, el DHCP\/PPPoE y el aprovisionamiento<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d22301bf\">La Asociaci\u00f3n de Fibra \u00d3ptica <a href=\"https:\/\/www.thefoa.org\/tech\/ref\/install\/Troubleshooting_FTTH.html\" target=\"_blank\" rel=\"noopener\">Gu\u00eda de resoluci\u00f3n de problemas de FTTH<\/a> Tambi\u00e9n describe c\u00f3mo un ONT defectuoso transmite de forma aleatoria o continua fuera del intervalo de tiempo correcto, lo que impide que otros ONT conectados al mismo puerto se comuniquen con el OLT.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-f77f5496\">Lo que no es una ONU \u00abrebelde\u00bb<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-852850a0\">No todas las interrupciones del servicio que afectan a varios usuarios<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ae99deb9\">Una aver\u00eda en la l\u00ednea de distribuci\u00f3n, un divisor da\u00f1ado, un puerto OLT desactivado, un problema en la tarjeta de l\u00ednea, un corte de corriente o un conector muy da\u00f1ado tambi\u00e9n pueden afectar a varios abonados. Una interrupci\u00f3n simult\u00e1nea es un indicio del alcance del problema, no un diagn\u00f3stico definitivo.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-6121a9d2\">No se trata simplemente de una potencia \u00f3ptica baja o alta<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-474961d8\">Una lectura de potencia normal en un intervalo de tiempo concreto no descarta que haya un transmisor atascado. El Suplemento 49 de la UIT-T explica que un transmisor no autorizado a plena potencia puede parecer normal en su propio intervalo, al tiempo que aumenta la potencia recibida en otros intervalos. Un medidor de potencia \u00f3ptica est\u00e1ndar no suele poder asociar una se\u00f1al de luz inesperada con una ONU y una asignaci\u00f3n espec\u00edficas. Utilice los datos de sincronizaci\u00f3n, r\u00e1fagas y alarmas del OLT, o un m\u00e9todo adecuado que tenga en cuenta las r\u00e1fagas.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-a67f349c\">No es lo mismo que O5 sin Internet<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-83ae26ef\">Si solo una ONU permanece estable en O5 pero no tiene direcci\u00f3n WAN, pasa a la capa superior de la PON. La gu\u00eda de LuLeey sobre un <a href=\"https:\/\/www.luleey.com\/es\/what-can-i-do-if-the-onu-state-is-o5-but-cannot-obtain-the-dhcp-ip-address\/\">ONU en O5 sin IP de DHCP<\/a> incluye VLAN, modo WAN, DHCP\/PPPoE y asignaci\u00f3n de servicios.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-efbc58a8\">No est\u00e1 certificado por una etiqueta SFP o SFP+<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-77f27f62\">En el caso de un Stick ONU, la compatibilidad del enlace por parte del host y el comportamiento de r\u00e1fagas por parte de la red PON son cuestiones independientes. No se debe deducir ninguna de ellas a partir del nombre de la jaula ni de la velocidad nominal del m\u00f3dulo. Comprueba los modelos exactos del Stick y del host, el PHY\/SerDes del host, el firmware y el controlador, la configuraci\u00f3n del puerto, la codificaci\u00f3n del m\u00f3dulo, el modo host del Stick, la velocidad real negociada del host y el rendimiento \u00fatil. Una ruta de host no compatible puede interrumpir el servicio local, pero eso no demuestra por s\u00ed solo que la ONU est\u00e9 transmitiendo fuera de su asignaci\u00f3n PON.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-43ad6551\">Flujo de trabajo para la resoluci\u00f3n de problemas de una ONU no autorizada<\/h2>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-6fef0c56\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22490\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/rogue-onu-troubleshooting-workflow.avif\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/rogue-onu-troubleshooting-workflow.avif 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/rogue-onu-troubleshooting-workflow-800x800.avif 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/rogue-onu-troubleshooting-workflow-400x400.avif 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/rogue-onu-troubleshooting-workflow-768x768.avif 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/rogue-onu-troubleshooting-workflow-12x12.avif 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/rogue-onu-troubleshooting-workflow-150x150.avif 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d7b57e65\">Utiliza primero las pruebas no invasivas. El aislamiento f\u00edsico de las ramas puede afectar a los suscriptores sanos y solo debe llevarlo a cabo personal autorizado durante un intervalo de mantenimiento aprobado.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-4a5bb6ff\">1. Guarda las pruebas antes de reiniciar el sistema<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2b6e64c3\">Registro:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>OLT, tarjeta de l\u00ednea, puerto PON y versi\u00f3n de software<\/li>\n\n\n\n<li>Nombres de las alarmas, marcas de tiempo y horas de desactivaci\u00f3n<\/li>\n\n\n\n<li>ONU afectadas en cada marca de tiempo<\/li>\n\n\n\n<li>Cambios en el estado de registro y contadores de errores en las etapas anteriores<\/li>\n\n\n\n<li>Cambios recientes en el firmware, la configuraci\u00f3n, el divisor o el trabajo de campo<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-12a2a6fe\">Si se reinicia primero, es posible que se elimine la evidencia temporal que permite distinguir un incidente aislado de una interrupci\u00f3n en la red com\u00fan.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-f8fa9826\">2. Definir el radio de la explosi\u00f3n<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8ead09c9\">Agrupa a los abonados afectados seg\u00fan la jerarqu\u00eda de la red:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Una ONU<\/li>\n\n\n\n<li>Una rama de bifurcaci\u00f3n<\/li>\n\n\n\n<li>Un puerto PON<\/li>\n\n\n\n<li>Varios puertos en una sola tarjeta<\/li>\n\n\n\n<li>Varios OLT o una ruta de agregaci\u00f3n ascendente<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a0876c70\">Una ONU defectuosa deber\u00eda apuntar hacia un canal PON compartido. Si las aver\u00edas afectan a puertos no relacionados entre s\u00ed, ampl\u00eda la investigaci\u00f3n antes de aislar las ramificaciones de los abonados.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-32f056a1\">3. Descartar las causas f\u00edsicas y relacionadas con el OLT m\u00e1s habituales<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-cd21c3a4\">Comprueba el distribuidor, el recorrido del divisor, el estado del puerto OLT, el estado de las tarjetas de l\u00ednea, la alimentaci\u00f3n del chasis y el mantenimiento reciente. Compara las tendencias \u00f3pticas en lugar de basarte en una sola lectura tomada tras la recuperaci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-037105fb\">Si el estado de activaci\u00f3n es la pista principal, utiliza el m\u00e9todo de LuLeey <a href=\"https:\/\/www.luleey.com\/es\/xgs-pon-onu-not-registering-check-o1-o7-states\/\">Flujo de trabajo de registro de la ONU O1\u2013O7<\/a> para mantener separadas las acciones de sincronizaci\u00f3n en sentido descendente, detecci\u00f3n, medici\u00f3n de distancia, provisi\u00f3n de servicios y desactivaci\u00f3n del OLT. Los ejemplos que se ofrecen son espec\u00edficos de XGS-PON, por lo que hay que ajustar el estado y el procedimiento a la documentaci\u00f3n exacta del equipo GPON.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-bdb27bda\">4. Utiliza la supervisi\u00f3n del OLT antes de desconectar las fibras<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-19410a33\">En cuanto al modelo exacto del OLT y la versi\u00f3n del software, busca pruebas que lo corroboren, como por ejemplo:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Potencia \u00f3ptica detectada durante un intervalo de silencio<\/li>\n\n\n\n<li>Una r\u00e1faga que llega fuera de su asignaci\u00f3n<\/li>\n\n\n\n<li>Desviaci\u00f3n de sincronizaci\u00f3n o fallo en la compensaci\u00f3n de la desviaci\u00f3n<\/li>\n\n\n\n<li>Patrones an\u00f3malos de FEC o BER en el sentido ascendente<\/li>\n\n\n\n<li>Errores en la delimitaci\u00f3n de r\u00e1fagas<\/li>\n\n\n\n<li>Una alarma espor\u00e1dica, de emisi\u00f3n continua o de luz prolongada<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-63fceb43\">Los nombres de las alarmas y los umbrales dependen del fabricante y de la versi\u00f3n. No pegues comandos de otra plataforma. Haz una copia de seguridad de la configuraci\u00f3n y sigue las instrucciones del manual actual correspondiente al modelo instalado.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-a606a253\">5. Aislar seg\u00fan la topolog\u00eda y confirmar la ONU sospechosa<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e28f851e\">Si el OLT no puede identificar la ONU de forma no invasiva, utiliza el mapa de divisores para delimitar la aver\u00eda:<\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li>Anuncia un periodo de mantenimiento e identifica a los clientes afectados.<\/li>\n\n\n\n<li>A\u00edsla una de las ramas del divisor situadas aguas abajo siguiendo el procedimiento aprobado.<\/li>\n\n\n\n<li>Comprueba si las ONU vecinas se recuperan y si la alarma se desactiva.<\/li>\n\n\n\n<li>Vuelve a conectarlo o mant\u00e9nlo aislado seg\u00fan el plan de cambios.<\/li>\n\n\n\n<li>Repite el proceso en la rama sospechosa hasta que se identifique una ONU o una derivaci\u00f3n.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-eb52e9df\">Nunca mires directamente al interior de una fibra o de un puerto \u00f3ptico. Considera que todos los conectores desconocidos est\u00e1n activos. No desconectes a los clientes al azar; cada cambio debe servir para comprobar una hip\u00f3tesis por escrito y debe quedar registrado.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f144ae3e\">Antes de la sustituci\u00f3n, coteja al menos dos tipos de pruebas:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>La alarma de \u00abrogue\u00bb o \u00ablong-light\u00bb del OLT indica que se trata de la misma derivaci\u00f3n u ONU<\/li>\n\n\n\n<li>Al eliminar al sospechoso, se restablecen las dem\u00e1s ONU<\/li>\n\n\n\n<li>Al volver a conectarlo, se reproduce el fallo en condiciones controladas.<\/li>\n\n\n\n<li>Un diagn\u00f3stico compatible muestra errores de luz fuera de asignaci\u00f3n o de r\u00e1faga<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4b2c4d00\">No reproduzcas repetidamente una situaci\u00f3n an\u00f3mala en una red de producci\u00f3n. Una comprobaci\u00f3n controlada puede ser suficiente cuando la alarma y el patr\u00f3n de recuperaci\u00f3n coinciden.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-16aab07d\">6. Sustituir, restaurar y supervisar<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ec02cc2a\">Utiliza una ONU autorizada que corresponda a la generaci\u00f3n PON, la clase \u00f3ptica y el firmware compatibles adecuados. Restablece la identidad y el perfil de servicio aprobados; no clones las credenciales de otro abonado.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4b864036\">A continuaci\u00f3n, comprueba lo siguiente:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>La alarma falsa permanece desactivada<\/li>\n\n\n\n<li>Las ONU de referencia se mantienen estables a lo largo del periodo de observaci\u00f3n<\/li>\n\n\n\n<li>Los contadores de errores de las etapas anteriores vuelven a su nivel normal<\/li>\n\n\n\n<li>El recambio alcanza el estado de activaci\u00f3n previsto<\/li>\n\n\n\n<li>La VLAN de abonados, el DHCP\/PPPoE y el tr\u00e1fico funcionan con normalidad<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-16e0c4be\">Documenta la versi\u00f3n del hardware o del firmware que ha fallado y las pruebas exactas. De este modo, lo que en un principio es una soluci\u00f3n puntual se convierte en una respuesta m\u00e1s r\u00e1pida ante el pr\u00f3ximo incidente.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-7ee35697\">Comprueba la detecci\u00f3n de dispositivos no autorizados (Rogue-ONU) al seleccionar un OLT<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9dad73e3\">El LuLeey actual <a href=\"https:\/\/www.luleey.com\/es\/producto\/8-pon-gpon-olt\/\">LL-GPOLT-XE-G08 OLT GPON de 8 puertos PON<\/a> En esta p\u00e1gina se detalla la detecci\u00f3n de unidades de red \u00f3ptica (ONU) con emisi\u00f3n de luz an\u00f3mala, incluida la emisi\u00f3n prolongada de luz. En la misma p\u00e1gina se identifica el modelo como LL-GPOLT-XE-G08 y se indica que es compatible con GPON seg\u00fan las normas UIT-T G.984\/G.988.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-bb1632ce\">Esto confirma que la funci\u00f3n est\u00e1 disponible para ese modelo; no especifica el algoritmo de detecci\u00f3n, los umbrales de alarma, el comportamiento de aislamiento autom\u00e1tico ni la sintaxis de los comandos para cada versi\u00f3n de firmware. Comprueba la versi\u00f3n exacta del software y el procedimiento operativo antes de confiar en cualquier acci\u00f3n autom\u00e1tica.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-8f7ce6bf\">Pr\u00f3ximo paso pr\u00e1ctico<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0235573c\">Antes de la pr\u00f3xima interrupci\u00f3n del servicio en los puertos compartidos, crea un mapa que relacione los puertos del OLT con las ramificaciones del divisor y los ID de las ONU, guarda las alarmas sincronizadas en el tiempo y prueba el flujo de trabajo aprobado para la detecci\u00f3n de dispositivos no autorizados en un laboratorio o durante una ventana de mantenimiento. Durante un incidente, trabaje partiendo de las pruebas para determinar el alcance y, a continuaci\u00f3n, de la derivaci\u00f3n a la ONU. Esto es m\u00e1s r\u00e1pido \u2014y m\u00e1s seguro\u2014 que sustituir todos los terminales que se encuentren desconectados.<\/p>","protected":false},"excerpt":{"rendered":"<p>Observaci\u00f3n: Qu\u00e9 indica. Qu\u00e9 conviene comprobar a continuaci\u00f3n. Una ONU est\u00e1 desconectada; los dispositivos conectados al mismo puerto PON siguen funcionando con normalidad. Local<\/p>","protected":false},"author":1,"featured_media":22491,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[886],"tags":[41,1712,1711,1642,53,1710,1709],"class_list":["post-22489","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-network-maintenance","tag-gpon","tag-ftth-troubleshooting","tag-long-light-onu","tag-network-maintenance","tag-olt","tag-rogue-ont","tag-rogue-onu"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/posts\/22489","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/comments?post=22489"}],"version-history":[{"count":0,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/posts\/22489\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/media\/22491"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/media?parent=22489"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/categories?post=22489"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/es\/wp-json\/wp\/v2\/tags?post=22489"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}