{"id":20664,"date":"2026-05-15T12:08:08","date_gmt":"2026-05-15T04:08:08","guid":{"rendered":"https:\/\/www.luleey.com\/?p=20664"},"modified":"2026-05-15T12:19:08","modified_gmt":"2026-05-15T04:19:08","slug":"mpo-fiber-connectors-types-polarity-gender-applications-for-40g-100g-data-centers","status":"publish","type":"post","link":"https:\/\/www.luleey.com\/fr\/mpo-fiber-connectors-types-polarity-gender-applications-for-40g-100g-data-centers\/","title":{"rendered":"Connecteurs fibre MPO : Types, polarit\u00e9, genre et applications pour les centres de donn\u00e9es 40G\/100G"},"content":{"rendered":"<h2 class=\"wp-block-wd-title title wd-50977340\">Introduction<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-16cbdc00\">Avec la croissance rapide du cloud computing, de la 5G et des services d'IA, les centres de donn\u00e9es ont besoin de solutions de c\u00e2blage en fibre optique plus denses, plus rapides et plus fiables. <strong><a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/fr\/tag\/mpo\/\" title=\"Voir tous les messages dans MPO\">MPO<\/a> (Multi-fiber Push-On) connecteurs de fibre<\/strong> sont devenus la norme industrielle pour la transmission optique parall\u00e8le \u00e0 40G, 100G et 400G.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-59844c1a\">Cet article explique en d\u00e9tail les connecteurs de fibre MPO en se basant sur <strong>EIA\/TIA-604-5 (FOCIS 5)<\/strong> et <strong>IEC-61754-7<\/strong> Les normes internationales, y compris le nombre de c\u0153urs, le genre m\u00e2le\/femelle, les trois types de polarit\u00e9 standardis\u00e9s, les avantages des syst\u00e8mes pr\u00e9termin\u00e9s et les applications du monde r\u00e9el. Toutes les informations sont v\u00e9rifi\u00e9es par rapport aux sp\u00e9cifications professionnelles de c\u00e2blage en fibre optique.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-ad00cd90\">Qu'est-ce qu'un connecteur fibre MPO ?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a6c0e9c5\">MPO est un connecteur optique multifibre con\u00e7u exclusivement pour les environnements de c\u00e2blage \u00e0 haute densit\u00e9. Il int\u00e8gre plusieurs fibres optiques dans une seule f\u00e9rule compacte, permettant des connexions rapides de type \"plug-and-play\" sans outils sp\u00e9ciaux.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5115192a\">Les connecteurs MPO sont largement utilis\u00e9s dans trois domaines principaux :<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>C\u00e2blage haute densit\u00e9 pour centres de donn\u00e9es<\/li>\n\n\n\n<li>R\u00e9seaux d'acc\u00e8s \u00e0 la fibre optique jusqu'au b\u00e2timent (FTTB)<\/li>\n\n\n\n<li>Connexions internes pour s\u00e9parateurs optiques et \u00e9metteurs-r\u00e9cepteurs SFP+\/QSFP 40G\/100G<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c687647d\">Tous les produits MPO pr\u00e9termin\u00e9s qualifi\u00e9s sont assembl\u00e9s en usine et 100% test\u00e9s optiquement pour garantir des performances et une fiabilit\u00e9 constantes.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-4ea98d42\">Nombre de c\u0153urs de fibre MPO communs (normalis\u00e9s)<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8a226cb3\">Les connecteurs MPO utilisent un <strong>12 fibres \u00e0 une rang\u00e9e<\/strong> comme unit\u00e9 structurelle de base, qui peut \u00eatre d\u00e9velopp\u00e9e en plusieurs rang\u00e9es. Les nombres de noyaux suivants sont conformes aux normes de l'industrie :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>8 c\u0153urs<\/strong>: Le plus courant pour les \u00e9metteurs-r\u00e9cepteurs 40G QSFP+ SR4 et 100G QSFP28 SR4 (4 fibres d'\u00e9mission + 4 fibres de r\u00e9ception).<\/li>\n\n\n\n<li><strong>12 c\u0153urs<\/strong>: Le plus largement utilis\u00e9 pour les liens MPO-MPO 40G et le patching quotidien des centres de donn\u00e9es.<\/li>\n\n\n\n<li><strong>24 c\u0153urs<\/strong>: Utilis\u00e9 pour la transmission \u00e0 courte distance 100G et le c\u00e2blage de backbone de rack \u00e0 rack<\/li>\n\n\n\n<li><strong>16\/32 c\u0153urs<\/strong>: Conception de la prochaine g\u00e9n\u00e9ration pour les r\u00e9seaux 400G \u00e0 ultra-haut d\u00e9bit et \u00e0 faible latence<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"703\" height=\"271\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image.png\" alt=\"\" class=\"wp-image-20665\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image.png 703w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-18x7.png 18w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-150x58.png 150w\" sizes=\"auto, (max-width: 703px) 100vw, 703px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-01d313aa\">Connecteur MPO : M\u00e2le vs femelle (r\u00e8gle critique d'accouplement)<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2892d6ca\">Les connecteurs MPO sont strictement divis\u00e9s en m\u00e2les et femelles. <strong>doivent \u00eatre utilis\u00e9s par paires m\u00e2le-femelle uniquement<\/strong>. Toute autre combinaison entra\u00eenera une d\u00e9faillance de la connexion ou des dommages physiques permanents aux connecteurs.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6ed5ee39\"><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"250\" height=\"167\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-4.png\" alt=\"\" class=\"wp-image-20672\" style=\"aspect-ratio:1.49704654642829;width:449px;height:auto\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-4.png 250w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-4-18x12.png 18w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-4-150x100.png 150w\" sizes=\"auto, (max-width: 250px) 100vw, 250px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Objet<\/th><th class=\"has-text-align-center\" data-align=\"center\">Connecteur MPO m\u00e2le<\/th><th class=\"has-text-align-center\" data-align=\"center\">Connecteur MPO femelle<\/th><\/tr><\/thead><tbody><tr><td>D\u00e9finition de la caract\u00e9ristique<\/td><td>\u00c9quip\u00e9 de deux broches de guidage de pr\u00e9cision sur la virole<\/td><td>Pas de goupilles de guidage, seulement des trous d'alignement correspondants<\/td><\/tr><tr><td>R\u00f4le d'alignement<\/td><td>Permet un positionnement exact des fibres lors de l'accouplement<\/td><td>Accepte les broches de guidage pour une connexion stable et \u00e0 faible perte<\/td><\/tr><tr><td>Applications typiques<\/td><td>C\u00e2bles de liaison, liaisons dorsales, ports de panneaux de brassage<\/td><td>Cordons de raccordement, \u00e9metteurs-r\u00e9cepteurs optiques, connexions c\u00f4t\u00e9 \u00e9quipement<\/td><\/tr><tr><td>Conformit\u00e9<\/td><td>EIA\/TIA-604-5, IEC-61754-7<\/td><td>EIA\/TIA-604-5, IEC-61754-7<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-a60826af\">Types de polarit\u00e9 MPO : Type A, Type B, Type C (normalis\u00e9)<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-bbe8cc51\">La polarit\u00e9 garantit que les fibres de transmission (Tx) se connectent correctement aux fibres de r\u00e9ception (Rx). Il existe trois types de polarit\u00e9 standardis\u00e9s au niveau international pour les c\u00e2bles MPO :<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-9bd52a9c\">1. Type A (direct)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Mappage des fibres : 1\u21921, 2\u21922, ..., 12\u219212 (s\u00e9quence identique aux deux extr\u00e9mit\u00e9s)<\/li>\n\n\n\n<li>Direction des touches : Touche Haut \u2194 Touche Bas (orientations oppos\u00e9es)<\/li>\n\n\n\n<li>Id\u00e9al pour : Connexions directes simples de point \u00e0 point, liaisons de commutation de serveur \u00e0TOR<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"700\" height=\"284\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-1.png\" alt=\"\" class=\"wp-image-20666\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-1.png 700w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-1-18x7.png 18w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-1-150x61.png 150w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-222e3791\">2. Type B (renversement complet \/ crois\u00e9)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Mappage des fibres : 1\u219212, 2\u219211, ..., 12\u21921 (s\u00e9quence inverse compl\u00e8te)<\/li>\n\n\n\n<li>Direction de la touche : Touche vers le haut \u2194 Touche vers le haut (m\u00eame orientation aux deux extr\u00e9mit\u00e9s)<\/li>\n\n\n\n<li>Meilleur pour : Connexions transversales de backbone, \u00e9quipement avec inversion de signal interne, \u00e9metteurs-r\u00e9cepteurs SR4 40G\/100G<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"700\" height=\"284\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-2.png\" alt=\"\" class=\"wp-image-20667\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-2.png 700w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-2-18x7.png 18w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-2-150x61.png 150w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-2f0bde93\">3. Type C (par paires)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Mappage des fibres : 1\u21942, 3\u21944, ..., 11\u219412 (paires de fibres adjacentes permut\u00e9es)<\/li>\n\n\n\n<li>Direction des touches : Touche Haut \u2194 Touche Bas (orientations oppos\u00e9es)<\/li>\n\n\n\n<li>Id\u00e9al pour : Syst\u00e8mes de transmission duplex et applications de signalisation par paires<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"700\" height=\"284\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-3.png\" alt=\"\" class=\"wp-image-20668\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-3.png 700w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-3-18x7.png 18w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/05\/image-3-150x61.png 150w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-c5d46ba1\">4 Avantages v\u00e9rifi\u00e9s des syst\u00e8mes de c\u00e2blage MPO pr\u00e9termin\u00e9s<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-88cc03f6\">Tous les avantages ci-dessous sont confirm\u00e9s par l'exp\u00e9rience de d\u00e9ploiement de centres de donn\u00e9es dans le monde r\u00e9el :<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Performance et flexibilit\u00e9 garanties<\/strong>Pr\u00e9termin\u00e9 en usine et test\u00e9 100%, \u00e9liminant les erreurs de terminaison sur le terrain. Permet une expansion transparente du r\u00e9seau et des mises \u00e0 niveau futures de la vitesse.<\/li>\n\n\n\n<li><strong>Une densit\u00e9 tr\u00e8s \u00e9lev\u00e9e pour un gain de place<\/strong>La conception modulaire et compacte r\u00e9duit l'encombrement des c\u00e2bles et des ports jusqu'\u00e0 70% par rapport aux connecteurs monofibre traditionnels, ce qui permet un c\u00e2blage \u00e0 plus haute densit\u00e9 dans un espace d'armoire limit\u00e9.<\/li>\n\n\n\n<li><strong>D\u00e9ploiement rapide et co\u00fbts de main-d'\u0153uvre r\u00e9duits<\/strong>L'installation pr\u00eate \u00e0 l'emploi ne n\u00e9cessite pas d'\u00e9pissure sur site ni d'outils sp\u00e9ciaux. R\u00e9duit le temps d'installation et les co\u00fbts de main d'\u0153uvre jusqu'\u00e0 70% par rapport \u00e0 un c\u00e2blage termin\u00e9 sur site.<\/li>\n\n\n\n<li><strong>Optimis\u00e9 pour les r\u00e9seaux \u00e0 haut d\u00e9bit<\/strong>Sp\u00e9cialement con\u00e7u pour la transmission optique parall\u00e8le, il constitue la seule solution viable pour les backbones 40G\/100G\/400G des centres de donn\u00e9es.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-6aafa527\">Applications typiques des connecteurs fibre MPO<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Centres de donn\u00e9es Hyperscale et d'entreprise<\/strong>: C\u00e2blage haute densit\u00e9 d'un rack \u00e0 l'autre, d'une rang\u00e9e \u00e0 l'autre et de la zone de distribution principale<\/li>\n\n\n\n<li><strong>\u00c9metteurs-r\u00e9cepteurs optiques \u00e0 haut d\u00e9bit<\/strong>: 40G QSFP+ SR4, 100G QSFP28 SR4, et autres modules optiques parall\u00e8les<\/li>\n\n\n\n<li><strong>FTTH ET FTTB<\/strong>: Acc\u00e8s \u00e0 la fibre optique dans les b\u00e2timents et c\u00e2blage r\u00e9sidentiel en fibre optique \u00e0 haut d\u00e9bit<\/li>\n\n\n\n<li><strong>R\u00e9partiteurs optiques et c\u00e2blage int\u00e9gr\u00e9<\/strong>: Sc\u00e9narios d'int\u00e9gration de liaisons optiques compactes<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-ab0a906e\">Guide de s\u00e9lection rapide des MPO (100% Accurate)<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pour <strong>40G\/100G QSFP+ SR4 \/ QSFP28 SR4<\/strong> \u00e9metteurs-r\u00e9cepteurs \u2192 Utilisation <strong>8-core Type B (crois\u00e9)<\/strong> C\u00e2bles MPO<\/li>\n\n\n\n<li>Pour le patching standard des centres de donn\u00e9es et les liens MPO-MPO 40G \u2192 Utiliser <strong>Type A \u00e0 12 fils<\/strong> C\u00e2bles MPO<\/li>\n\n\n\n<li>Pour les connexions transversales de la dorsale et la transmission \u00e0 courte distance 100G \u2192 Utiliser <strong>24-core Type B<\/strong> C\u00e2bles MPO<\/li>\n\n\n\n<li>Pour les r\u00e9seaux 400G \u00e0 faible latence \u2192 Utiliser <strong>16\/32 c\u0153urs<\/strong> Connecteurs MPO<\/li>\n\n\n\n<li>V\u00e9rifiez toujours : <strong>m\u00e2le \u2194 femelle<\/strong> accouplement + polarit\u00e9 correcte avant le d\u00e9ploiement<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-55af2938\">Questions fr\u00e9quemment pos\u00e9es (br\u00e8ves et faisant autorit\u00e9)<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-2325bbb6\">Q1 : Puis-je connecter deux connecteurs MPO m\u00e2les ou deux connecteurs MPO femelles ensemble ?<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-017cd71b\"><strong>A<\/strong>: Non. Les connecteurs MPO n\u00e9cessitent <strong>un homme et une femme<\/strong> pour s'accoupler correctement. Les connexions m\u00e2le-m\u00e2le ou femelle-femelle endommageront les embouts et provoqueront une perte de signal permanente.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-21d42286\">Q2 : Quelle polarit\u00e9 MPO dois-je utiliser pour les transceivers 100G SR4 ?<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-356bfaf4\"><strong>A<\/strong>: Utilisation <strong>8-core Type B (full reversed)<\/strong> C\u00e2bles MPO. Il s'agit du standard industriel pour tous les modules optiques parall\u00e8les SR4 40G et 100G.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-7d6fb69d\">Q3 : Quel est le nombre maximum de fibres qu'un connecteur MPO peut supporter ?<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-64eecc88\"><strong>A<\/strong>: Les connecteurs MPO standard supportent de 6 \u00e0 144 fibres. Les tailles les plus courantes sont 8, 12 et 24 c\u0153urs pour les applications des centres de donn\u00e9es modernes.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-fcc7e2f5\">Q4 : Les c\u00e2bles MPO pr\u00e9termin\u00e9s sont-ils meilleurs que les c\u00e2bles termin\u00e9s sur le terrain ?<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3be5446c\"><strong>A<\/strong>: Oui. Les c\u00e2bles MPO pr\u00e9termin\u00e9s sont 100% test\u00e9s en usine, offrent des performances plus constantes, s'installent 70% plus rapidement et pr\u00e9sentent des taux de d\u00e9faillance \u00e0 long terme inf\u00e9rieurs \u00e0 ceux des c\u00e2bles termin\u00e9s sur le terrain.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-6c107466\">Q5 : Quelle est la diff\u00e9rence entre les c\u00e2bles MPO \u00e0 12 et 24 conducteurs ?<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9bb7f577\"><strong>A<\/strong>: Les c\u00e2bles MPO \u00e0 12 fils utilisent une seule rang\u00e9e de fibres et sont id\u00e9aux pour le brassage g\u00e9n\u00e9ral. Les c\u00e2bles MPO \u00e0 24 fils utilisent deux rang\u00e9es de fibres et sont con\u00e7us pour le c\u00e2blage de backbone \u00e0 haute capacit\u00e9 et la transmission 100G.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-04acece2\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-eff65c3c\">Les connecteurs de fibre MPO sont le composant fondamental du c\u00e2blage moderne des centres de donn\u00e9es \u00e0 haute densit\u00e9 et \u00e0 grande vitesse. Il est essentiel de comprendre le nombre de c\u0153urs, les exigences en mati\u00e8re de genre m\u00e2le\/femelle et les trois types de polarit\u00e9 standardis\u00e9s pour construire des r\u00e9seaux 40G\/100G\/400G stables et efficaces.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-50eb0297\">Avec une pr\u00e9termination en usine, une conformit\u00e9 totale aux normes internationales et une excellente \u00e9volutivit\u00e9, les syst\u00e8mes MPO offrent la fiabilit\u00e9, la densit\u00e9 et la rentabilit\u00e9 requises pour les centres de donn\u00e9es d'aujourd'hui et de demain.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-38201c2e\">Exp\u00e9dition directe depuis notre usine de fibres, Customize MPO Cable\uff1a<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2b59b4f3\"><a href=\"https:\/\/www.luleey.com\/fr\/categorie-produit\/fiber-optic-cables\/mtp-mpo-fiber-cables\/page\/1\/\">Archives des c\u00e2bles \u00e0 fibres MTP\/MPO - LuLeey.com | One-stop Optical Fiber Product Supplier<\/a><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d244ae5d\"><a href=\"https:\/\/www.luleey.com\/fr\/categorie-produit\/fiber-optic-cables\/fiber-optic-loopback\/\">Fiber Optic Loopback Archives - LuLeey.com | One-stop Optical Fiber Product Supplier<\/a><\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Article Connecteur MPO m\u00e2le Connecteur MPO femelle Caract\u00e9ristiques \u00c9quip\u00e9 de deux broches de guidage de pr\u00e9cision sur la virole Pas de guidage<\/p>","protected":false},"author":1,"featured_media":15060,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[891],"tags":[1155],"class_list":["post-20664","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-network-cabling","tag-mpo"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/posts\/20664","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/comments?post=20664"}],"version-history":[{"count":3,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/posts\/20664\/revisions"}],"predecessor-version":[{"id":20673,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/posts\/20664\/revisions\/20673"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/media\/15060"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/media?parent=20664"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/categories?post=20664"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/tags?post=20664"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}