{"id":22361,"date":"2026-09-24T12:37:44","date_gmt":"2026-09-24T04:37:44","guid":{"rendered":"https:\/\/www.luleey.com\/?p=22361"},"modified":"2026-09-23T12:59:19","modified_gmt":"2026-09-23T04:59:19","slug":"sfp-rx-los-vs-tx-fault-what-each-alarm-means","status":"publish","type":"post","link":"https:\/\/www.luleey.com\/fr\/sfp-rx-los-vs-tx-fault-what-each-alarm-means\/","title":{"rendered":"Erreur \u00ab SFP RX LOS \u00bb vs \u00ab TX \u00bb : signification de chaque alarme"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-9ece3cbf\"><strong><a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/fr\/tag\/sfp\/\" title=\"Voir tous les messages dans SFP\">SFP<\/a> <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/fr\/tag\/rx-los\/\" title=\"Afficher tous les articles de la rubrique RX LOS\">RX LOS<\/a> contre <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/fr\/tag\/tx-fault\/\" title=\"Afficher tous les articles de la rubrique \u00ab TX Fault \u00bb\">Erreur TX<\/a><\/strong> Il s'agit d'une question de d\u00e9pannage cibl\u00e9e, et non de deux noms d\u00e9signant la m\u00eame panne. \u00ab RX LOS \u00bb signifie que le module local signale une perte de signal en r\u00e9ception. \u00ab TX Fault \u00bb signifie que le module local signale un probl\u00e8me au niveau de son \u00e9metteur.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-90a88710\">Aucun de ces \u00e9tats, pris isol\u00e9ment, ne prouve que l'\u00e9metteur-r\u00e9cepteur complet est d\u00e9fectueux. Commencez par l'extr\u00e9mit\u00e9 qui signale l'\u00e9tat, identifiez la direction concern\u00e9e, puis testez une partie de cette direction \u00e0 la fois.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2aafb900\">Ce guide traite des modules SFP Ethernet optiques point \u00e0 point courants et <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/fr\/tag\/sfp-2\/\" title=\"Voir tous les messages dans SFP+\">SFP+<\/a> liens. Les libell\u00e9s exacts, la polarit\u00e9 et la configuration des bornes peuvent varier selon le module et l'h\u00f4te ; veuillez donc vous reporter aux manuels du mat\u00e9riel concern\u00e9.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-36b3e9d8\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22362\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-847767e5\">Erreur LOS sur le canal de r\u00e9ception (RX) du SFP vs erreur sur le canal de transmission (TX) : une diff\u00e9rence d'une minute<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3546919a\">Supposons une liaison duplex simple entre le dispositif A et le dispositif B.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u00c9tat affich\u00e9 sur l'appareil B<\/th><th>Ce que le module indique<\/th><th>Premier axe \u00e0 examiner<\/th><th>Ce que cela ne prouve pas<\/th><\/tr><\/thead><tbody><tr><td>RX LOS activ\u00e9<\/td><td>Le r\u00e9cepteur de B ne d\u00e9tecte pas de signal entrant acceptable<\/td><td>Un \u00e9metteur \u2192 un trajet par fibre optique de A vers B \u2192 un r\u00e9cepteur \u00e0 B<\/td><td>Le r\u00e9cepteur de B est sans aucun doute d\u00e9fectueux.<\/td><\/tr><tr><td>Erreur TX d\u00e9tect\u00e9e<\/td><td>Le module B signale un d\u00e9faut de l'\u00e9metteur local<\/td><td>Alimentation\/commande de l'h\u00f4te B \u2192 \u00c9metteur du module B<\/td><td>La fibre optique B-A est endommag\u00e9e<\/td><\/tr><tr><td>Tous deux ont affirm\u00e9<\/td><td>B pr\u00e9sente un d\u00e9faut local au niveau de l'\u00e9mission et ne re\u00e7oit pas non plus de signal acceptable.<\/td><td>Traitez les directions s\u00e9par\u00e9ment, puis v\u00e9rifiez l'alimentation partag\u00e9e, la configuration et l'\u00e9tat du module<\/td><td>Une seule coupure de fibre suffit \u00e0 expliquer tous les sympt\u00f4mes<\/td><\/tr><tr><td>Aucune affirmation, mais le lien ne fonctionne pas<\/td><td>Ces deux signaux d'\u00e9tat ne permettent pas d'identifier la cause<\/td><td>PMD, d\u00e9bit, FEC, mode h\u00f4te, codage, polarit\u00e9 et \u00e9tat du pair<\/td><td>La configuration physique et \u00e9lectrique est compatible<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6095e855\">Le courant <a href=\"https:\/\/members.snia.org\/document\/dl\/25880\" target=\"_blank\" rel=\"noopener\">Sp\u00e9cification SNIA SFF-8419<\/a> cartes <code>Tx_Fault<\/code> en tant que sortie de d\u00e9faut de l'\u00e9metteur du module et <code>Rx_LOS<\/code> comme indication de perte de signal c\u00f4t\u00e9 r\u00e9cepteur. Dans Ethernet, le signal de r\u00e9ception peut \u00e9galement \u00eatre repr\u00e9sent\u00e9 sous la forme <strong>D\u00e9tection de signal<\/strong>. Un animateur peut donc pr\u00e9senter la m\u00eame situation sous un angle positif ou n\u00e9gatif, par exemple : <code>RX LOS : Oui<\/code> ou <code>D\u00e9tection de signal : Non<\/code>.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3f341e3c\">N'interpr\u00e9tez pas un terme que vous ne connaissez pas <code>Erreur RX<\/code> \u00e9tiquette jusqu'\u00e0 ce que le manuel de la plateforme pr\u00e9cise s'il s'agit d'une perte de liaison radio (RX LOS), d'une faible puissance de r\u00e9ception (RX), d'un d\u00e9faut PCS ou d'une autre condition combin\u00e9e.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-faabc045\">Les points RX LOS sont orient\u00e9s vers la direction d'arriv\u00e9e<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-258b847d\">Si le dispositif B signale une perte de signal de r\u00e9ception (RX LOS), commencez par la direction optique qui devrait arriver vers B :<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8332752b\"><strong>A TX \u2192 connecteur A \u2192 trajet de la fibre optique \u2192 connecteur B \u2192 B RX<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-96271753\">Parmi les causes possibles, on peut citer un \u00e9metteur d\u00e9sactiv\u00e9 ou d\u00e9fectueux au point A, une polarit\u00e9 duplex invers\u00e9e, un connecteur d\u00e9branch\u00e9 ou encrass\u00e9, une perte de trajet excessive, un type de fibre inadapt\u00e9, des longueurs d'onde ou des PMD incompatibles, une paire BiDi A\/B incorrecte, ou encore un probl\u00e8me au niveau du r\u00e9cepteur du point B. Le message \u00ab RX LOS \u00bb permet de restreindre la direction du probl\u00e8me ; il ne permet pas d'identifier un composant d\u00e9fectueux en particulier.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1b834363\">V\u00e9rifiez s\u00e9par\u00e9ment la direction inverse. Il se peut que B ne re\u00e7oive rien de la part de A, alors que A continue de recevoir normalement des donn\u00e9es de la part de B. Une simple ic\u00f4ne \u00ab Link Down \u00bb masque souvent cette diff\u00e9rence de sens.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-36b41886\">Pour une liaison duplex, v\u00e9rifiez que chaque \u00e9metteur atteint le r\u00e9cepteur situ\u00e9 \u00e0 l'autre bout. Pour une liaison BiDi \u00e0 fibre unique, v\u00e9rifiez que les longueurs d'onde d'\u00e9mission et de r\u00e9ception sont compl\u00e9mentaires ; deux modules orient\u00e9s dans la m\u00eame direction ne constituent pas une paire standard.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-773f86cd\">Le d\u00e9faut TX est localis\u00e9 du c\u00f4t\u00e9 de l'\u00e9metteur<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b18959a0\">Si le p\u00e9riph\u00e9rique B signale une erreur de transmission (TX Fault), concentrez-vous d'abord sur le module B et sur la mani\u00e8re dont son h\u00f4te alimente et contr\u00f4le l'\u00e9metteur. V\u00e9rifiez si l'h\u00f4te a intentionnellement activ\u00e9 la d\u00e9sactivation de la transmission (TX Disable), si les donn\u00e9es de diagnostic sont valides apr\u00e8s l'initialisation, et si la tension, la temp\u00e9rature ou tout autre avertissement de l'\u00e9metteur pr\u00e9sente une anomalie pour ce module pr\u00e9cis.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-de56146d\">\u00ab TX Disable \u00bb et \u00ab TX Fault \u00bb sont deux signaux distincts. \u00ab TX Disable \u00bb est une commande \u00e9mise par l'h\u00f4te vers le module qui d\u00e9sactive l'\u00e9metteur. \u00ab TX Fault \u00bb est un \u00e9tat transmis par le module \u00e0 l'h\u00f4te. Un \u00e9metteur d\u00e9sactiv\u00e9 peut entra\u00eener l'affichage d'un message \u00ab RX LOS \u00bb \u00e0 l'extr\u00e9mit\u00e9 distante sans pour autant prouver que l'\u00e9metteur est d\u00e9faillant.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a94df145\">Lorsque le DDM est disponible, comparez l\u2019erreur TX avec la temp\u00e9rature, la tension d\u2019alimentation, la polarisation TX et la puissance de sortie TX correspondant au m\u00eame horodatage. LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/fr\/sfp-tx-bias-current-high-causes-and-fixes\/\">Guide sur le courant de polarisation TX des modules SFP<\/a> explique pourquoi la combinaison d'un avertissement de d\u00e9calage, d'une baisse de la puissance d'\u00e9mission et d'un d\u00e9faut d'\u00e9mission fournit davantage d'informations qu'une valeur prise isol\u00e9ment.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d768143c\">Ne r\u00e9initialisez pas \u00e0 plusieurs reprises un module de production et ne le d\u00e9branchez pas \u00e0 chaud dans le seul but d'effacer l'indicateur. Respectez la proc\u00e9dure propre \u00e0 l'h\u00f4te et au module, pr\u00e9servez les preuves d'origine et profitez d'une plage horaire de maintenance approuv\u00e9e.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-b479039e\">L'alarme \u00ab RX LOS \u00bb n'est pas la m\u00eame chose qu'une alarme de puissance RX<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1c6fdc12\"><a href=\"https:\/\/members.snia.org\/document\/dl\/25916\" target=\"_blank\" rel=\"noopener\">SFF-8472 R\u00e9v. 12.5a<\/a> d\u00e9finit les \u00e9tats \u00ab TX Fault \u00bb (d\u00e9faillance d'\u00e9mission num\u00e9rique) et \u00ab RX LOS \u00bb (perte de signal de r\u00e9ception) ind\u00e9pendamment des indicateurs d'alarme et d'avertissement optionnels relatifs \u00e0 la temp\u00e9rature, \u00e0 la tension, \u00e0 la polarisation d'\u00e9mission, \u00e0 la puissance d'\u00e9mission et \u00e0 la puissance optique re\u00e7ue. Il rend \u00e9galement la surveillance logicielle facultative.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-16f56dd5\">Cette distinction est importante :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><code>RX LOS<\/code> il s'agit d'un indicateur d'\u00e9tat du signal.<\/li>\n\n\n\n<li><code>Avertissement de faible puissance RX<\/code> compare une valeur surveill\u00e9e \u00e0 un seuil d'alerte programm\u00e9.<\/li>\n\n\n\n<li><code>Alarme de faible puissance RX<\/code> il s'agit d'un indicateur de seuil plus grave.<\/li>\n\n\n\n<li>La valeur affich\u00e9e en dBm correspond \u00e0 une mesure de diagnostic \u00e9chantillonn\u00e9e, dont la pr\u00e9cision et la m\u00e9thode de pr\u00e9sentation sont propres \u00e0 chaque module.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d7abb9a3\">Les seuils et le comportement ne doivent pas n\u00e9cessairement \u00eatre identiques. Un module peut signaler une certaine puissance re\u00e7ue tout en ne reconnaissant pas pour autant un signal acceptable pour le PMD et le d\u00e9bit s\u00e9lectionn\u00e9s. \u00c0 l'inverse, un h\u00f4te peut ne pas signaler une perte de liaison de r\u00e9ception (RX LOS) m\u00eame s'il utilise en interne la broche d'\u00e9tat physique.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-91948d7c\">Utilisez LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/fr\/what-is-ddm-dom-in-sfp-transceivers\/\">Guide pratique DDM\/DOM<\/a> pour obtenir un aper\u00e7u complet. Comparez la puissance d'\u00e9mission locale \u00e0 la puissance de r\u00e9ception \u00e0 distance pour la m\u00eame direction, et respectez scrupuleusement les limites minimales et maximales de fonctionnement du module. Il n'existe pas de valeur universelle \u201c id\u00e9ale \u201d en dBm.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-ab588b48\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22363\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-4af6aad6\">Un workflow contr\u00f4l\u00e9 pour les d\u00e9fauts de liaison de transmission (LOS) et d'\u00e9mission (TX) dans les r\u00e9seaux RX<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-121a61f3\">1. Notez la configuration exacte<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c974b8bc\">Enregistrez \u00e0 la fois les mod\u00e8les d'h\u00f4tes et les ports, les versions du micrologiciel et des pilotes, les r\u00e9f\u00e9rences et r\u00e9visions des modules, le codage, le PMD optique, le d\u00e9bit configur\u00e9 ou n\u00e9goci\u00e9, le FEC et le mode du port. Enregistrez simultan\u00e9ment l'\u00e9tat des deux extr\u00e9mit\u00e9s, les valeurs DDM, les \u00e9v\u00e9nements de liaison et les compteurs d'erreurs.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-24c33d1f\">La mention \u00ab SFP \u00bb, \u00ab SFP+ \u00bb ou \u00ab SFP28 \u00bb ne garantit pas la compatibilit\u00e9. La compatibilit\u00e9 physique, le mode SerDes de l'h\u00f4te, le codage du module, la vitesse de fonctionnement r\u00e9elle et le d\u00e9bit utilisable sont des \u00e9l\u00e9ments distincts.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-ba2b92a9\">2. V\u00e9rifiez l'\u00e9tiquette et indiquez-le<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d20cf8c9\">Consultez la d\u00e9finition exacte de la plateforme pour <code>RX LOS<\/code>, <code>D\u00e9tection de signal<\/code>, <code>Erreur RX<\/code>, <code>Erreur TX<\/code> et <code>TX D\u00e9sactiver<\/code>. Attendez que le module renvoie des donn\u00e9es valides apr\u00e8s son d\u00e9marrage, puis v\u00e9rifiez que cet \u00e9tat est stable en effectuant une deuxi\u00e8me lecture.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f4e7bc18\">Ne partez pas du principe que <code>1<\/code> signifie toujours que tout va bien ou qu'une ic\u00f4ne verte sur le tableau de bord pr\u00e9vaut sur l'\u00e9tat r\u00e9el.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-6acf6eef\">3. Tracer l'itin\u00e9raire dans les deux sens<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-052bc45f\">\u00c9crivez le lien sous la forme de deux chemins :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>A (\u00e9mission) \u2192 B (r\u00e9ception)<\/strong><\/li>\n\n\n\n<li><strong>B TX \u2192 A RX<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-39258fdd\">Si B pr\u00e9sente une perte de liaison (LOS) en r\u00e9ception (RX), v\u00e9rifiez le premier chemin. Si B pr\u00e9sente un d\u00e9faut d'\u00e9mission (TX Fault) et qu'A pr\u00e9sente une perte de liaison (LOS) en r\u00e9ception (RX), les deux observations concordent sur le <strong>B TX \u2192 A RX<\/strong> orientation et font de la partie \u00e9mission de B un candidat plus probable. Ils n'excluent toutefois pas encore un probl\u00e8me d'alimentation de l'h\u00f4te, une d\u00e9sactivation de l'\u00e9mission (TX Disable) ou un deuxi\u00e8me d\u00e9faut.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-be76f0b7\">4. V\u00e9rifier la correspondance optique<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6029bfdf\">V\u00e9rifiez le d\u00e9bit et le PMD, la cat\u00e9gorie de fibre, la longueur d'onde, la famille de connecteurs et le polissage, la polarit\u00e9 duplex ou le couplage BiDi, ainsi que la plage de puissance de r\u00e9ception dans chaque sens. Il ne suffit pas qu'un connecteur soit simplement compatible.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-cea0e60b\">Inspectez et nettoyez les connecteurs accessibles en suivant la proc\u00e9dure approuv\u00e9e par le propri\u00e9taire du r\u00e9seau. Le <a href=\"https:\/\/foa.org\/tech\/ref\/testing\/test\/scope.html\" target=\"_blank\" rel=\"noopener\">Guide des connecteurs de la Fiber Optic Association<\/a> explique comment la contamination entra\u00eene des pertes et une r\u00e9flectance, et peut se propager entre des ferrules accoupl\u00e9es. Ne regardez jamais directement dans une fibre ou un port optique ; utilisez un wattm\u00e8tre adapt\u00e9 et une m\u00e9thode d'inspection vid\u00e9o.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-59a1521d\">5. Isoler un composant<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-af1656ae\">Au cours d'une fen\u00eatre de maintenance autoris\u00e9e, remplacez le c\u00e2ble de raccordement ou le module par un autre dont le bon fonctionnement est av\u00e9r\u00e9 et qui correspond aux sp\u00e9cifications, puis r\u00e9p\u00e9tez les m\u00eames observations. Si le d\u00e9faut se limite \u00e0 un seul module entre deux ports pris en charge, cela renforce l\u2019hypoth\u00e8se relative au module. Si le message \u00ab RX LOS \u00bb persiste dans un seul sens de transmission, inspectez ce chemin. S\u2019il persiste au niveau d\u2019un seul port h\u00f4te, examinez l\u2019h\u00f4te et sa configuration.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f8dcf4e9\">Une boucle locale peut r\u00e9duire la longueur du trajet local, mais uniquement apr\u00e8s avoir adapt\u00e9 le PMD, la fibre, le connecteur et la puissance du r\u00e9cepteur. LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/fr\/how-to-test-an-sfp-port-with-a-fiber-loopback\/\">Guide de test de bouclage de fibre optique<\/a> explique les limites : une boucle fonctionnelle ne permet pas de tester la ligne de production ni le homologue distant, et une auto-boucle passive ne constitue pas un test g\u00e9n\u00e9ral valable pour les composants optiques bidirectionnels \u00e0 longueurs d'onde compl\u00e9mentaires.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-eca936c6\">6. V\u00e9rifier le trafic, et pas seulement l'\u00e9tat<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f165184f\">Une fois que l'\u00e9tat est r\u00e9tabli, v\u00e9rifiez la stabilit\u00e9 de la liaison, le d\u00e9bit r\u00e9el et les variations des compteurs dans les deux sens. Le fait que l'indicateur \u00ab RX LOS \u00bb soit d\u00e9sactiv\u00e9 signifie simplement que cette indication de perte particuli\u00e8re n'est pas activ\u00e9e. Cela ne garantit pas que les trames Ethernet soient intactes ni que le d\u00e9bit soit conforme aux attentes.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2d5d1d13\">Si la connexion fonctionne mais que le nombre d'erreurs FCS\/CRC augmente, suivez les instructions de LuLeey <a href=\"https:\/\/www.luleey.com\/fr\/sfp-crc-errors-with-normal-rx-power-what-to-check\/\">Liste de contr\u00f4le pour le d\u00e9pannage du CRC des modules SFP<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-72dab416\">Erreurs courantes \u00e0 \u00e9viter<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Remplacer le r\u00e9cepteur de B simplement parce que B signale une perte de liaison (RX LOS)<\/li>\n\n\n\n<li>Consid\u00e9rer \u00ab TX Disable \u00bb comme une preuve d'\u00e9chec de la transmission TX<\/li>\n\n\n\n<li>Lecture des valeurs TX et RX locales dans une m\u00eame direction optique<\/li>\n\n\n\n<li>Remplacer simultan\u00e9ment les deux optiques et les deux c\u00e2bles de raccordement<\/li>\n\n\n\n<li>Utiliser une valeur g\u00e9n\u00e9rique de longueur d'onde ou de dBm au lieu des donn\u00e9es exactes figurant dans les fiches techniques<\/li>\n\n\n\n<li>D\u00e9clarer l'op\u00e9ration r\u00e9ussie lorsque l'alarme dispara\u00eet sans v\u00e9rifier le trafic et les compteurs<\/li>\n\n\n\n<li>Sans tenir compte des param\u00e8tres SerDes, du d\u00e9bit, de la FEC, du codage, du micrologiciel ou des param\u00e8tres du port<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5795d495\">Ce guide de proc\u00e9dure ne constitue pas un guide d'enregistrement PON. Une cl\u00e9 ONU PON 2,5G int\u00e8gre une logique ONU et peut pr\u00e9senter un comportement diff\u00e9rent vis-\u00e0-vis de l'h\u00f4te. Un h\u00f4te SFP+ 1G\/10G ne peut le prendre en charge \u00e0 1G que si la cl\u00e9 et l'h\u00f4te prennent tous deux en charge un mode 1G compatible ; certains ports SFP+ ne peuvent prendre en charge le 2,5G qu'avec le chipset\/PHY, le micrologiciel ou le pilote, les param\u00e8tres de port, le codage du module et le mode h\u00f4te de la cl\u00e9 appropri\u00e9s.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-4454f2f7\">O\u00f9 utiliser les \u00e9quipements LuLeey ?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9a4475c4\">Pour un test multimode local contr\u00f4l\u00e9, LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/fr\/produit-2\/fiber-optic-loopback-lc-upc-om3-mm\/\">Boucle de retour en fibre LC\/UPC OM3<\/a> Cette page indique un chemin multimode de 50\/125 \u00b5m, une interface LC\/UPC et une perte d'insertion ne d\u00e9passant pas 0,2 dB. Ces sp\u00e9cifications n'en font pas pour autant un produit universel. Cette valeur correspond \u00e0 une perte maximale et non \u00e0 une att\u00e9nuation de protection garantie ; v\u00e9rifiez la valeur exacte du PMD et l'entr\u00e9e maximale du r\u00e9cepteur avant de r\u00e9aliser une boucle courte.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-15a60686\">Pour une demande de remplacement ou une v\u00e9rification de compatibilit\u00e9, veuillez envoyer \u00e0 LuLeey les mod\u00e8les des deux h\u00f4tes, les r\u00e9f\u00e9rences et r\u00e9visions des modules, le micrologiciel, le mode de port, les d\u00e9tails relatifs \u00e0 la fibre optique et aux connecteurs, les \u00e9tats \u2019 TX Fault \u00bb, \u00ab RX LOS \u00bb et \u00ab TX Disable \u00bb aux deux extr\u00e9mit\u00e9s, les instantan\u00e9s DDM complets, les horodatages des \u00e9v\u00e9nements de liaison et les variations des compteurs.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u00c9tat affich\u00e9 sur l'appareil B Ce que le module signale Premier point \u00e0 v\u00e9rifier Ce que cela ne prouve pas RX<\/p>","protected":false},"author":1,"featured_media":22362,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[886],"tags":[69,1680,1642,1669,1682,71,1681],"class_list":["post-22361","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-network-maintenance","tag-sfp","tag-loss-of-signal","tag-network-maintenance","tag-optical-troubleshooting","tag-rx-los","tag-sfp-2","tag-tx-fault"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/posts\/22361","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/comments?post=22361"}],"version-history":[{"count":1,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/posts\/22361\/revisions"}],"predecessor-version":[{"id":22372,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/posts\/22361\/revisions\/22372"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/media\/22362"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/media?parent=22361"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/categories?post=22361"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/tags?post=22361"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}