{"id":22416,"date":"2026-09-28T16:49:41","date_gmt":"2026-09-28T08:49:41","guid":{"rendered":"https:\/\/www.luleey.com\/?p=22416"},"modified":"2026-09-27T16:53:54","modified_gmt":"2026-09-27T08:53:54","slug":"media-converter-vlan-passthrough-a-practical-guide","status":"publish","type":"post","link":"https:\/\/www.luleey.com\/fr\/media-converter-vlan-passthrough-a-practical-guide\/","title":{"rendered":"Convertisseur de m\u00e9dias avec transmission VLAN : guide pratique"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-e25cd59e\"><strong><a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/fr\/tag\/media-converter\/\" title=\"Voir tous les messages dans MEDIA CONVERTER\">CONVERTISSEUR DE M\u00c9DIAS<\/a> <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/fr\/tag\/vlan-passthrough\/\" title=\"Afficher tous les articles sur le \u00ab VLAN Passthrough \u00bb\">Transfert VLAN<\/a><\/strong> est possible lorsque le convertisseur conserve les balises Ethernet et accepte l'int\u00e9gralit\u00e9 de la <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/fr\/tag\/frame-size\/\" title=\"Afficher tous les articles de la rubrique \u00ab Taille du cadre \u00bb\">Taille du cadre<\/a>. Toutefois, les termes \u201c non g\u00e9r\u00e9 \u201d, \u201c Gigabit \u201d ou \u201c 10G \u201d ne garantissent pas que ces capacit\u00e9s soient disponibles sur un mod\u00e8le particulier.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-35e9bc2a\">Par exemple, une connexion par fibre optique peut acheminer sans probl\u00e8me un r\u00e9seau classique non balis\u00e9, alors qu\u2019une liaison montante vers un commutateur balis\u00e9 \u00e9choue. La cause peut provenir du convertisseur, mais elle peut \u00e9galement \u00eatre li\u00e9e \u00e0 un port envoyant des trames non balis\u00e9es, \u00e0 un VLAN exclu du commutateur distant ou \u00e0 une limite de taille de trame.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c8f570d5\">Voici comment distinguer ces diff\u00e9rentes possibilit\u00e9s avant d'acheter du mat\u00e9riel de remplacement.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-b126f487\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22418\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/media-converter-vlan-passthrough-hero.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/media-converter-vlan-passthrough-hero.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/media-converter-vlan-passthrough-hero-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/media-converter-vlan-passthrough-hero-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/media-converter-vlan-passthrough-hero-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/media-converter-vlan-passthrough-hero-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/media-converter-vlan-passthrough-hero-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-9416855e\">Que signifie r\u00e9ellement le \u00ab VLAN passthrough \u00bb d'un convertisseur de m\u00e9dias ?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8f4c3563\">Pour un chemin transparent, un cadre entrant avec l'ID de VLAN 100 doit sortir avec la m\u00eame balise VLAN. Le passage du cuivre \u00e0 la fibre optique ne n\u00e9cessite pas, en soi, de modifier cette balise.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-772f4365\">Il est facile de confondre trois notions :<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Capacit\u00e9<\/th><th>Fonctionnalit\u00e9s<\/th><\/tr><\/thead><tbody><tr><td>Transfert VLAN<\/td><td>Conserve une balise existante tout au long du parcours de conversion<\/td><\/tr><tr><td>Configuration du VLAN<\/td><td>Attribue, supprime, traduit ou filtre les balises en fonction des param\u00e8tres<\/td><\/tr><tr><td>Routage inter-VLAN<\/td><td>Achmine le trafic IP entre diff\u00e9rents VLAN gr\u00e2ce \u00e0 une fonction de routage<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-47349abe\">Un convertisseur peut laisser passer une trame balis\u00e9e sans proposer de menu de configuration VLAN. \u00c0 l'inverse, un p\u00e9riph\u00e9rique g\u00e9r\u00e9 peut d\u00e9lib\u00e9r\u00e9ment filtrer ou modifier les balises. Le <a href=\"https:\/\/docs.kernel.org\/networking\/bridge.html?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Documentation sur les ponts du noyau Linux<\/a> Cela illustre comment l'activation du filtrage VLAN fait en sorte que le transfert de paquets d\u00e9pende \u00e0 la fois de l'appartenance \u00e0 un VLAN et de l'adresse MAC de destination. Il s'agit d'une explication utile de cette distinction, et non d'une preuve concernant le mat\u00e9riel d'un convertisseur sp\u00e9cifique. <a href=\"https:\/\/docs.kernel.org\/networking\/bridge.html?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">La documentation du noyau Linux<\/a><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c0270953\">Si la connexion physique elle-m\u00eame est instable, commencez par suivre les conseils de LuLeey <a href=\"https:\/\/www.luleey.com\/fr\/fiber-media-converter-lights-on-but-no-network\/?utm_source=chatgpt.com\">Guide de d\u00e9pannage du convertisseur de m\u00e9dia \u00ab Lights-On \u00bb<\/a> Tout d'abord.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-f14e9a28\">V\u00e9rifiez la taille des trames, et pas seulement la valeur \u201c MTU 1500 \u201d<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-29178ec3\">Un ordinaire <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/fr\/tag\/802-1q\/\" title=\"Afficher tous les articles sur la norme 802.1Q\">802.1Q<\/a> La balise VLAN ajoute quatre octets \u00e0 une trame Ethernet. Avec une charge utile Ethernet de 1 500 octets, les tailles obtenues sont les suivantes :<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Marquage<\/th><th>Longueur d'une trame Ethernet<\/th><\/tr><\/thead><tbody><tr><td>Pas de balise VLAN<\/td><td>1 518 octets<\/td><\/tr><tr><td>Une balise VLAN<\/td><td>1 522 octets<\/td><\/tr><tr><td>Deux balises VLAN, telles que <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/fr\/tag\/qinq\/\" title=\"Afficher tous les articles de QinQ\">QinQ<\/a><\/td><td>1 526 octets<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ef841d3f\">Ces chiffres incluent l'en-t\u00eate Ethernet et le FCS de quatre octets. Ils excluent le pr\u00e9ambule, le d\u00e9limiteur de d\u00e9but de trame et l'intervalle entre paquets. La valeur pour deux balises est de 1 518 + 4 + 4 ; elle suppose que la charge utile est toujours de 1 500 octets et qu'aucune encapsulation suppl\u00e9mentaire n'est ajout\u00e9e.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e60012a0\">Le <a href=\"https:\/\/wiki.wireshark.org\/Ethernet?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">R\u00e9f\u00e9rence Ethernet de Wireshark<\/a> d\u00e9crit les champs de la trame de base et la balise VLAN de quatre octets. Le tableau applique ces champs \u00e0 la m\u00eame charge utile de 1 500 octets. <a href=\"https:\/\/wiki.wireshark.org\/Ethernet?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Wiki Wireshark<\/a><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d3fcbb22\">Une sp\u00e9cification indiquant simplement \u201c MTU 1500 \u201d est ambigu\u00eb si elle ne pr\u00e9cise pas ce qui est pris en compte. Demandez quelle est la taille maximale accept\u00e9e pour une trame Ethernet et si ce chiffre inclut les balises et le FCS. La pr\u00e9sence d\u2019une seule balise ne suffit pas non plus \u00e0 garantir la prise en charge de QinQ : v\u00e9rifiez s\u00e9par\u00e9ment les types de balises, le comportement des balises empil\u00e9es et la taille de trame requise.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-28952318\">V\u00e9rifiez ce que transmettent les deux ports d'extr\u00e9mit\u00e9<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5fb4a472\">Notez l'ID du VLAN et pr\u00e9cisez si le trafic doit \u00eatre balis\u00e9 ou non \u00e0 chaque connexion.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ffb6aeb8\">Pour une simple extension du VLAN 100 entre deux commutateurs g\u00e9r\u00e9s, les deux ports reli\u00e9s au convertisseur transparent doivent acheminer le trafic du VLAN 100 avec balises. Les p\u00e9riph\u00e9riques connect\u00e9s aux ports d\u2019acc\u00e8s peuvent toujours envoyer du trafic ordinaire sans balises ; leurs commutateurs g\u00e8rent les balises sur la liaison montante.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e8f91dad\">V\u00e9rifiez les param\u00e8tres r\u00e9els, plut\u00f4t que de vous fier au terme \u201c trunk \u201d :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Le VLAN requis est-il autoris\u00e9 sur les deux liaisons montantes ?<\/li>\n\n\n\n<li>L'un ou l'autre de ces ports transmet-il ce VLAN sans balise en tant que VLAN natif ?<\/li>\n\n\n\n<li>Quel VLAN re\u00e7oit le trafic entrant non balis\u00e9 : le PVID du port ?<\/li>\n\n\n\n<li>Y a-t-il un appareil g\u00e9r\u00e9 interm\u00e9diaire qui filtre ou traduit les balises ?<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-84b55b3f\">Cet exemple permet de tester la conservation des balises. Il n'est pas n\u00e9cessaire d'activer tous les VLAN sur une liaison montante en production.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-669827e0\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22417\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/vlan-ethernet-frame-size.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/vlan-ethernet-frame-size.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/vlan-ethernet-frame-size-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/vlan-ethernet-frame-size-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/vlan-ethernet-frame-size-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/vlan-ethernet-frame-size-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/vlan-ethernet-frame-size-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-508769de\">Test pratique du \u00ab VLAN Passthrough \u00bb<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e7352f59\">Utilisez un r\u00e9seau de test isol\u00e9 ou une plage horaire de maintenance convenue. Enregistrez d'abord les param\u00e8tres existants.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-bf3c04c4\">1. \u00c9tablir une r\u00e9f\u00e9rence dont le bon fonctionnement est av\u00e9r\u00e9<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-17dcf3ac\">Utilisez deux commutateurs prenant en charge les VLAN et placez un ordinateur de test derri\u00e8re chacun d'eux. Placez les ports d'acc\u00e8s orient\u00e9s vers les ordinateurs dans le VLAN 100 et configurez les ports inter-commutateurs pour qu'ils acheminent le VLAN 100 avec balisage. Attribuez aux ordinateurs des adresses appropri\u00e9es et uniques au sein du m\u00eame sous-r\u00e9seau de test.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-39c2f37b\">V\u00e9rifiez la communication via une connexion directe dont vous savez qu\u2019elle fonctionne. D\u00e9connectez ensuite cette connexion et ins\u00e9rez le chemin compos\u00e9 du convertisseur et de la fibre correspondant entre les m\u00eames ports du commutateur. Ne modifiez pas les param\u00e8tres du VLAN ni les ordinateurs de test. Ne laissez pas les deux chemins connect\u00e9s afin d\u2019\u00e9viter de cr\u00e9er accidentellement une boucle.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d0bae6dd\">Enregistrez les d\u00e9bits de fonctionnement apr\u00e8s la substitution. Avec les convertisseurs enfichables, la compatibilit\u00e9 physique, le mode SerDes de l\u2019h\u00f4te, le d\u00e9bit configur\u00e9 ou n\u00e9goci\u00e9 et le d\u00e9bit utile font l\u2019objet de v\u00e9rifications distinctes. V\u00e9rifiez le mod\u00e8le exact du convertisseur et du module, le chipset\/PHY de l\u2019h\u00f4te, le micrologiciel ou le pilote, les param\u00e8tres du port et le codage du module.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-3c572847\">2. Tester les deux sens et plusieurs tailles de paquets<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5e5a2840\">Commencez par un faible d\u00e9bit, puis testez la taille de paquet maximale requise par le service. Un ping par d\u00e9faut r\u00e9ussi ne constitue qu'un test avec des paquets de petite taille.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-37161ac8\">Pour l'exemple de charge utile de 1 500 octets \u00e0 balise unique, v\u00e9rifiez que le test g\u00e9n\u00e8re bien des trames Ethernet de 1 522 octets, FCS compris. La \u201c taille de paquet \u201d d'un outil peut faire r\u00e9f\u00e9rence \u00e0 la longueur IP ou \u00e0 la charge utile du test ; il se peut \u00e9galement que l'outil fragmente le trafic. V\u00e9rifiez la convention de taille de l\u2019outil et assurez-vous que la fragmentation ne masque pas la limite.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8708f3aa\">R\u00e9p\u00e9tez l'op\u00e9ration dans les deux sens. Enregistrez les trames de test transmises et re\u00e7ues, les pertes de trames et les variations du compteur d'erreurs. Si le service utilise QinQ ou des charges utiles plus importantes, ajoutez ces cas pr\u00e9cis s\u00e9par\u00e9ment.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-1b39310f\">3. V\u00e9rifier les \u00e9tiquettes aux points de mesure<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4a31fb6b\">Capturez le flux de test en amont et en aval du chemin de conversion \u00e0 l'aide de prises de mesure adapt\u00e9es ou de ports de mise en miroir du commutateur. V\u00e9rifiez que la configuration de mise en miroir conserve les balises et que l'adaptateur de capture les rend visibles.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-899d7ac8\">Le <a href=\"https:\/\/wiki.wireshark.org\/CaptureSetup\/VLAN?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Guide de capture VLAN avec Wireshark<\/a> explique pourquoi le syst\u00e8me d'exploitation, l'interface de capture, la carte r\u00e9seau ou le pilote peuvent masquer des balises. V\u00e9rifiez la configuration de la capture \u00e0 l'aide d'un flux balis\u00e9 connu avant d'imputer au convertisseur la responsabilit\u00e9 d'une balise manquante. Les captures peuvent \u00e9galement omettre le FCS ; la longueur affich\u00e9e peut donc \u00eatre inf\u00e9rieure de quatre octets \u00e0 celle indiqu\u00e9e dans le tableau ci-dessus. <a href=\"https:\/\/wiki.wireshark.org\/CaptureSetup\/VLAN?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Wiki Wireshark<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-d5d867cc\">4. Interpr\u00e9ter le r\u00e9sultat<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Observation contr\u00f4l\u00e9e<\/th><th>V\u00e9rification suivante<\/th><\/tr><\/thead><tbody><tr><td>Le chemin de r\u00e9f\u00e9rence fonctionne ; le chemin du convertisseur \u00e9choue, m\u00eame avec de petites trames balis\u00e9es<\/td><td>V\u00e9rifiez \u00e0 nouveau le marquage des points d'extr\u00e9mit\u00e9, le transfert par le convertisseur et le chemin d'acc\u00e8s physique<\/td><\/tr><tr><td>Le trafic non balis\u00e9 fonctionne ; le trafic balis\u00e9 \u00e9choue lors d'une comparaison contr\u00f4l\u00e9e<\/td><td>V\u00e9rifier la conservation effective des balises et le filtrage VLAN \u00e0 chaque p\u00e9rim\u00e8tre<\/td><\/tr><tr><td>Les petits cadres \u00e9tiquet\u00e9s fonctionnent ; les plus grands \u00e9chouent<\/td><td>\u00c9tudier les limites de taille des trames, le dimensionnement des outils de test et la fragmentation<\/td><\/tr><tr><td>Les m\u00eames balises sont re\u00e7ues, mais le DHCP ou l'acc\u00e8s \u00e0 Internet ne fonctionne pas<\/td><td>V\u00e9rifiez le chemin de retour, la disponibilit\u00e9 du DHCP et des services, le routage et la politique de pare-feu<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c0c747e8\">Ces r\u00e9sultats affinent le champ d'investigation ; aucun d'entre eux ne permet \u00e0 lui seul d'identifier un convertisseur d\u00e9fectueux. De m\u00eame, un test de ping ou un test de d\u00e9bit Internet ne permet pas de v\u00e9rifier tous les VLAN, toutes les tailles de trames ou tous les protocoles de contr\u00f4le.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-2eb10e77\">\u00c9l\u00e9ments \u00e0 v\u00e9rifier avant de passer commande<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-17b4c6e1\">LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/fr\/categorie-produit\/fiber-optic-transceiver\/copper-to-fiber-media-converters\/?utm_source=chatgpt.com\">Gamme de convertisseurs de m\u00e9dia cuivre-fibre optique<\/a> constitue un point de d\u00e9part pour choisir le type de connexion physique.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0f418b03\">Par exemple, le <a href=\"https:\/\/www.luleey.com\/fr\/produit-2\/ll-sfpmc10grtl-10g-sfp-to-rj45-media-convertersupport-xgs-pon-epon-stick\/?utm_source=chatgpt.com\">Page produit LL-SFPMC10GRTL<\/a> mentionne une puce RTL8261C, un port SFP+ 10G\/2,5G et un port RJ45 multid\u00e9bit. La page n'indique pas la taille maximale des trames Ethernet et ne fournit pas non plus de matrice de test de transit VLAN\/QinQ. Ces sp\u00e9cifications d'interface ne suffisent pas \u00e0 elles seules \u00e0 confirmer votre service balis\u00e9.<\/p>","protected":false},"excerpt":{"rendered":"<p>Fonctionnalit\u00e9 Description Passage de VLAN Transmet une balise existante \u00e0 travers le chemin de conversion Configuration VLAN Attribue, supprime, traduit ou<\/p>","protected":false},"author":1,"featured_media":22418,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[887],"tags":[51,1698,1697,1696,1699,1694,1695],"class_list":["post-22416","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-data-transmission-conversion","tag-media-converter","tag-802-1q","tag-fiber-ethernet","tag-frame-size","tag-qinq","tag-vlan-passthrough","tag-vlan-troubleshooting"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/posts\/22416","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/comments?post=22416"}],"version-history":[{"count":1,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/posts\/22416\/revisions"}],"predecessor-version":[{"id":22419,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/posts\/22416\/revisions\/22419"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/media\/22418"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/media?parent=22416"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/categories?post=22416"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/tags?post=22416"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}