{"id":23199,"date":"2026-10-30T21:57:41","date_gmt":"2026-10-30T13:57:41","guid":{"rendered":"https:\/\/www.luleey.com\/?p=23199"},"modified":"2026-10-25T22:09:00","modified_gmt":"2026-10-25T14:09:00","slug":"sgmii-vs-1000base-x-why-1-25-gbd-is-not-enough","status":"publish","type":"post","link":"https:\/\/www.luleey.com\/fr\/sgmii-vs-1000base-x-why-1-25-gbd-is-not-enough\/","title":{"rendered":"SGMII contre 1000BASE-X : pourquoi 1,25 GBd ne suffit pas"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-55854493\"><strong><a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/fr\/tag\/sgmii\/\" title=\"View all posts in SGMII\">SGMII<\/a> contre <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/fr\/tag\/1000base-x\/\" title=\"Afficher tous les articles sur le 1000BASE-X\">1000BASE-X<\/a><\/strong> Cela peut sembler \u00eatre un simple d\u00e9tail de d\u00e9nomination, car les deux modes peuvent utiliser une voie s\u00e9rie \u00e0 1,25 GBd avec un codage 8b\/10b. Cette similitude est r\u00e9elle, mais elle ne suffit pas \u00e0 prouver la compatibilit\u00e9. Ces deux modes desservent g\u00e9n\u00e9ralement des parties diff\u00e9rentes d\u2019un syst\u00e8me Ethernet, et ils n\u2019attribuent pas la m\u00eame signification au mot de contr\u00f4le en bande de 16 bits.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c8861796\">Par cons\u00e9quent, un module peut s'adapter \u00e0 la cage et son EEPROM peut \u00eatre lisible alors m\u00eame que la liaison de donn\u00e9es reste inactive. Une paire non compatible peut m\u00eame transmettre une partie du trafic tout en fournissant des informations erron\u00e9es concernant l'\u00e9tat de la liaison, la vitesse, le mode duplex ou la pause. La solution la plus s\u00fbre consiste \u00e0 faire correspondre les <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/fr\/tag\/host-serdes\/\" title=\"View all posts in Host SerDes\">SerDes h\u00f4te<\/a>\/Mode PCS, et pas seulement le connecteur et la vitesse de transmission.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-874d54ad\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-23201\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/sgmii-vs-1000base-x-hero-1000x1000-1.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/sgmii-vs-1000base-x-hero-1000x1000-1.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/sgmii-vs-1000base-x-hero-1000x1000-1-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/sgmii-vs-1000base-x-hero-1000x1000-1-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/sgmii-vs-1000base-x-hero-1000x1000-1-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/sgmii-vs-1000base-x-hero-1000x1000-1-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/sgmii-vs-1000base-x-hero-1000x1000-1-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-c8fd64f4\">Comparaison rapide entre SGMII et 1000BASE-X<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>V\u00e9rifier<\/th><th>SGMII<\/th><th>1000BASE-X<\/th><\/tr><\/thead><tbody><tr><td>R\u00f4le principal<\/td><td>Interface s\u00e9rie entre un MAC et un PHY<\/td><td>Mode PCS\/liaison Gigabit Ethernet IEEE 802.3 utilis\u00e9 avec des modules PHY 1G et des liaisons optiques<\/td><\/tr><tr><td>Un pair typique<\/td><td>PHY \u00ab Copper \u00bb ou \u00e0 plusieurs vitesses transmettant son r\u00e9sultat c\u00f4t\u00e9 support au MAC<\/td><td>Un autre partenaire de liaison 1000BASE-X ; un module SFP optique 1G standard utilise g\u00e9n\u00e9ralement ce chemin c\u00f4t\u00e9 h\u00f4te<\/td><\/tr><tr><td>Voie s\u00e9rie \u00e0 1 G<\/td><td>1,25 GBd, 8b\/10b<\/td><td>1,25 GBd, 8b\/10b<\/td><\/tr><tr><td>D\u00e9bits Ethernet indiqu\u00e9s<\/td><td>10, 100 et 1 000 Mb\/s ; les d\u00e9bits inf\u00e9rieurs utilisent la r\u00e9plication de symboles<\/td><td>1 Gb\/s dans cette comparaison<\/td><\/tr><tr><td>Mot en bande<\/td><td>Le PHY signale le type de liaison, la vitesse et le mode duplex c\u00f4t\u00e9 support ; le MAC accuse r\u00e9ception<\/td><td>\u00c9change de liens entre partenaires <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/fr\/tag\/clause-37\/\" title=\"View all posts in Clause 37\">Article 37<\/a> fonctions telles que l'impression recto-verso et la mise en pause<\/td><\/tr><tr><td>Base standard<\/td><td>SGMII tel que d\u00e9fini par Cisco, bas\u00e9 sur les m\u00e9canismes 1000BASE-X<\/td><td>Clauses 36 et 37 de la norme IEEE 802.3<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-cee92e65\"><code>GBd<\/code> Cela correspond au nombre de symboles par seconde, et non au d\u00e9bit utile de l'application. Sur ces voies s\u00e9rie binaires, 1,25 milliard de symboles cod\u00e9s par seconde transportent 1 Gb\/s une fois le rapport de codage 8b\/10b appliqu\u00e9. La mise en trame Ethernet et les protocoles de couches sup\u00e9rieures r\u00e9duisent encore davantage le d\u00e9bit utile de la charge utile.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-039239ea\">Le d\u00e9bit de ligne partag\u00e9 explique pourquoi il est facile de confondre ces modes. La diff\u00e9rence de signification des mots de contr\u00f4le explique pourquoi un h\u00f4te doit tout de m\u00eame s\u00e9lectionner le mode appropri\u00e9. La documentation de Linux et celle de Microchip d\u00e9crivent chacune de leur c\u00f4t\u00e9 cette distinction. <\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-fc6c4863\">Pourquoi une voie de 1,25 GBd peut-elle tout de m\u00eame pr\u00e9senter des d\u00e9faillances ?<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-e974366e\">Le mot de contr\u00f4le r\u00e9pond \u00e0 une autre question<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1e083a0c\">Sur une liaison 1000BASE-X standard, les informations relatives \u00e0 la clause 37 sont \u00e9chang\u00e9es entre les partenaires de la liaison. Elles permettent d'\u00e9tablir la liaison Gigabit Ethernet et de coordonner certaines fonctionnalit\u00e9s, telles que le mode duplex et le comportement en mode pause.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d5110726\">Le protocole SGMII r\u00e9utilise le transport s\u00e9rie, mais r\u00e9affecte le mot de contr\u00f4le \u00e0 la relation entre la couche MAC et la couche PHY. Une couche physique 10\/100\/1000BASE-T peut n\u00e9gocier avec le p\u00e9riph\u00e9rique via son connecteur RJ45, puis communiquer \u00e0 la couche MAC, via SGMII, l'\u00e9tat de la liaison, la vitesse et le mode duplex obtenus. Il s'agit de n\u00e9gociations distinctes couvrant des domaines distincts.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6086dfb4\">Si un MAC interpr\u00e8te un mot SGMII comme un mot 1000BASE-X, ou inversement, le r\u00e9cepteur \u00e9lectrique peut d\u00e9tecter un flux valide de 1,25 GBd alors que l'\u00e9tat logique reste erron\u00e9.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-94780053\">Une incompatibilit\u00e9 ne se traduit pas toujours par une simple \u201c perte de connexion \u201d.\u201d<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2eab279e\">La documentation du noyau Linux signale qu'une incompatibilit\u00e9 entre les normes SGMII et 1000BASE-X peut, dans certaines circonstances, entra\u00eener la transmission de donn\u00e9es alors que le mot de contr\u00f4le de 16 bits est mal interpr\u00e9t\u00e9. Les sympt\u00f4mes possibles sont les suivants :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Aucune liaison de donn\u00e9es n'est \u00e9tablie, bien que le module soit d\u00e9tect\u00e9.<\/li>\n\n\n\n<li>Un lien qui s'affiche avec un statut ou des param\u00e8tres incorrects.<\/li>\n\n\n\n<li>Un module SFP en cuivre qui ne fonctionne qu'\u00e0 un seul d\u00e9bit c\u00f4t\u00e9 support.<\/li>\n\n\n\n<li>Comportement incorrect en mode pause ou duplex.<\/li>\n\n\n\n<li>Des tests courts qui aboutissent \u00e0 des r\u00e9sultats positifs, suivis d'erreurs ou d'un comportement d\u00e9faillant en cas de charge \u00e9lev\u00e9e.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d7ed3040\">Ne consid\u00e9rez pas un seul ping r\u00e9ussi comme la preuve que les modes d'interface sont correctement align\u00e9s.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-fe4dfe89\">La d\u00e9tection emprunte un chemin diff\u00e9rent de celui du trafic utilisateur<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d4734f79\">Un h\u00f4te de la famille SFP peut lire l'identifiant du module via l'interface de gestion sans \u00e9tablir le chemin de donn\u00e9es \u00e0 haut d\u00e9bit. L'affichage du nom du fabricant ou d'un message \u201c module pr\u00e9sent \u201d ne prouve pas :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Un d\u00e9bit SerDes h\u00f4te compatible.<\/li>\n\n\n\n<li>Le mode PCS SGMII ou 1000BASE-X appropri\u00e9.<\/li>\n\n\n\n<li>Gestion correcte de l'\u00e9tat \u00ab in-band \u00bb.<\/li>\n\n\n\n<li>Compatibilit\u00e9 des protocoles c\u00f4t\u00e9 support.<\/li>\n\n\n\n<li>Le d\u00e9bit n\u00e9goci\u00e9 ou le d\u00e9bit utile final.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-002a9887\">La cage, le silicium h\u00f4te, le micrologiciel, le pilote, la configuration du port et le p\u00e9riph\u00e9rique connect\u00e9 ont tous leur importance.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-ef1f541f\">O\u00f9 chaque mode appara\u00eet g\u00e9n\u00e9ralement<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-2f8c11a0\">Liaisons optiques SFP 1G standard<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b94c1356\">Un module SFP optique simple de 1 G convertit g\u00e9n\u00e9ralement le signal \u00e9lectrique s\u00e9rie de l'h\u00f4te en lumi\u00e8re, et inversement. Le module MAC\/PCS de l'h\u00f4te g\u00e8re le codage 1000BASE-X et, le cas \u00e9ch\u00e9ant, le comportement d\u00e9fini dans la clause 37.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-85a733d5\">Les deux extr\u00e9mit\u00e9s optiques doivent toujours \u00eatre compatibles avec le PMD Ethernet, le d\u00e9bit de ligne, le type de fibre, le plan de longueurs d'onde, la plage de puissance optique et la polarit\u00e9.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-2a48d5e7\">PHY cuivre 10\/100\/1000BASE-T et SFP cuivre<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-39e22548\">Le SGMII est une interface MAC-PHY courante pour un PHY cuivre multi-d\u00e9bits. Le PHY cuivre n\u00e9gocie avec le p\u00e9riph\u00e9rique RJ45 distant, tandis que son mot de contr\u00f4le SGMII transmet ce r\u00e9sultat au MAC h\u00f4te.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-11a8c8a3\">Cependant, tous les modules SFP en cuivre ne fournissent pas l'interface SGMII \u00e0 leur h\u00f4te. Certains conservent une liaison h\u00f4te fixe de type 1000BASE-X et effectuent l'adaptation de d\u00e9bit en interne. D'autres n\u00e9cessitent l'interface SGMII. Une appellation de produit telle que \u201c SFP Gigabit RJ45 \u201d ne permet pas de d\u00e9terminer quelle architecture est int\u00e9gr\u00e9e.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-f7af911b\">PON <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/fr\/tag\/onu-stick\/\" title=\"Afficher tous les articles de la rubrique \u00ab ONU Stick \u00bb\">B\u00e2ton ONU<\/a>s<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e70dff24\">Une cl\u00e9 ONU PON est un dispositif actif du r\u00e9seau d'acc\u00e8s, et non pas simplement un \u00e9metteur-r\u00e9cepteur optique transparent. Son interface h\u00f4te d\u00e9pend du mod\u00e8le et du micrologiciel. Selon le Stick et le mode de fonctionnement, il peut n\u00e9cessiter une interface 1000BASE-X, SGMII, 2500BASE-X, un mode sp\u00e9cifique au fabricant avec une fr\u00e9quence d\u2019horloge augment\u00e9e ou une autre interface.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c4989ded\">Ne tirez pas de conclusion quant \u00e0 la compatibilit\u00e9 \u00e0 partir de <code>SFP<\/code>, <code>SFP+<\/code>, <code>1G<\/code>, <code>2.5G<\/code> ou le d\u00e9bit de la ligne PON uniquement.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c821facf\">Une cl\u00e9 ONU PON 2,5G ne peut fonctionner via une liaison 1G que si la cl\u00e9 et l'h\u00f4te prennent tous deux en charge un mode h\u00f4te 1G compatible. Certains h\u00f4tes SFP+ peuvent prendre en charge la vitesse 2,5G \u00e0 condition de disposer d'un chipset ou d'un module PHY adapt\u00e9, d'un micrologiciel ou d'un pilote compatible, d'une configuration de port appropri\u00e9e et d'un codage de module ad\u00e9quat.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-579c8471\">Le d\u00e9bit r\u00e9el de l'h\u00f4te d\u00e9termine la limite maximale du r\u00e9seau Ethernet. Un mode h\u00f4te 1G ne permet pas d'atteindre un d\u00e9bit Ethernet de 2,5G.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-64dc9114\">Quatre points \u00e0 v\u00e9rifier en mati\u00e8re de compatibilit\u00e9<\/h2>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-a4597f72\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-23200\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/sgmii-vs-1000base-x-checklist-1000x1000-1.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/sgmii-vs-1000base-x-checklist-1000x1000-1.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/sgmii-vs-1000base-x-checklist-1000x1000-1-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/sgmii-vs-1000base-x-checklist-1000x1000-1-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/sgmii-vs-1000base-x-checklist-1000x1000-1-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/sgmii-vs-1000base-x-checklist-1000x1000-1-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/10\/sgmii-vs-1000base-x-checklist-1000x1000-1-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Portail<\/th><th>Question<\/th><th>Des preuves insuffisantes<\/th><\/tr><\/thead><tbody><tr><td>1. Physique<\/td><td>Ce module est-il compatible avec le bo\u00eetier de la gamme SFP ?<\/td><td>Il s'enfonce et se verrouille<\/td><\/tr><tr><td>2. Gestion<\/td><td>L'h\u00f4te peut-il le d\u00e9tecter et l'identifier ?<\/td><td>Le nom du fournisseur, le num\u00e9ro de s\u00e9rie ou la temp\u00e9rature sont visibles<\/td><\/tr><tr><td>3. Chemin d'acc\u00e8s aux donn\u00e9es de l'h\u00f4te<\/td><td>Les deux c\u00f4t\u00e9s utilisent-ils le m\u00eame d\u00e9bit SerDes, le m\u00eame PCS et le m\u00eame mode intrabande ?<\/td><td>Ces deux documents mentionnent \u201c 1,25 G \u201d.\u201d<\/td><\/tr><tr><td>4. Service op\u00e9rationnel<\/td><td>Le protocole, le pair, le micrologiciel, l'authentification, les VLAN et le d\u00e9bit observ\u00e9 correspondent-ils ?<\/td><td>Une LED de liaison est allum\u00e9e<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9f3cba4e\">Un d\u00e9ploiement n'est pr\u00eat qu'une fois que les quatre \u00e9tapes ont \u00e9t\u00e9 valid\u00e9es. Le fait de franchir l'\u00e9tape 1 ou l'\u00e9tape 2 ne garantit pas le franchissement de l'\u00e9tape 3.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-7885cacd\">Proc\u00e9dure de d\u00e9pannage s\u00e9curis\u00e9e pour SGMII et 1000BASE-X<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-8f33d338\">1. Noter les identit\u00e9s exactes<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3a2441b8\">Notez le mod\u00e8le de l'h\u00f4te, le num\u00e9ro de port, le chipset ou le PHY indiqu\u00e9, la version du micrologiciel ou du pilote, le mod\u00e8le du module ou de la cl\u00e9, la r\u00e9vision mat\u00e9rielle et le code du module. Enregistrez la configuration actuelle avant d'effectuer toute modification.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-9d52b87e\">2. Identifier les modes d'interface pris en charge par l'h\u00f4te<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a1c81358\">Recherchez des termes explicites tels que <code>SGMII<\/code>, <code>1000BASE-X<\/code>, <code>2500BASE-X<\/code>, <code>\u00e9tat \u00ab in-band \u00bb<\/code> ou un param\u00e9trage bimode document\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8150e5d6\">\u201cLes termes \u201d port SFP \u201c, \u201d port 1G \u201c et \u201d auto \u00bb ne constituent pas des sp\u00e9cifications de mode. Le mode \u00ab auto \u00bb peut uniquement choisir parmi les modes pris en charge par cette puce et ce micrologiciel pr\u00e9cis.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4b38239a\">Les syst\u00e8mes Linux peuvent souvent fournir des informations sur la vitesse de fonctionnement et l'\u00e9tat de la liaison \u00e0 l'aide de <code>ethtool<\/code>, mais il se peut que la sortie ne r\u00e9v\u00e8le pas le mode PCS interne. Les journaux du pilote, la configuration du micrologiciel, la documentation du fabricant ou le sch\u00e9ma de la carte peuvent tout de m\u00eame s'av\u00e9rer n\u00e9cessaires.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-39605a1a\">3. D\u00e9terminez les exigences c\u00f4t\u00e9 h\u00f4te du p\u00e9riph\u00e9rique connect\u00e9<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-824d6c58\">S\u00e9parer l'interface orient\u00e9e h\u00f4te de l'interface orient\u00e9e support.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-bf7a00cc\">Pour un module SFP en cuivre, v\u00e9rifiez les caract\u00e9ristiques qu\u2019il pr\u00e9sente \u00e0 l\u2019h\u00f4te ainsi que les param\u00e8tres n\u00e9goci\u00e9s par son module PHY RJ45. Pour une cl\u00e9 ONU, v\u00e9rifiez le mode h\u00f4te correspondant \u00e0 la version exacte du micrologiciel et au d\u00e9bit demand\u00e9 \u2014 et pas seulement ses sp\u00e9cifications optiques GPON ou XGS-PON.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-51b1e79d\">4. Taux de correspondance, PCS et gestion des statuts<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ae9200f1\">V\u00e9rifiez tous ces \u00e9l\u00e9ments ensemble :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Compatibilit\u00e9 physique des cages et des broches.<\/li>\n\n\n\n<li>D\u00e9bit par voie SerDes c\u00f4t\u00e9 h\u00f4te.<\/li>\n\n\n\n<li>Mode SGMII ou 1000BASE-X PCS\/mot de contr\u00f4le.<\/li>\n\n\n\n<li>Si le statut \u00ab in-band \u00bb est obligatoire, facultatif ou d\u00e9sactiv\u00e9.<\/li>\n\n\n\n<li>Codage des modules et comportement de la liste blanche de l'h\u00f4te.<\/li>\n\n\n\n<li>Limites de puissance et thermiques.<\/li>\n\n\n\n<li>Taux effectivement n\u00e9goci\u00e9 ou d\u00e9fini.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a17c2e63\">Ne forcez pas un mode simplement pour v\u00e9rifier s'il fonctionne. N'utilisez qu'un mode pris en charge par les deux appareils, et effectuez les modifications pendant une fen\u00eatre de maintenance approuv\u00e9e.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-78db437f\">5. Comparer avec une r\u00e9f\u00e9rence contr\u00f4l\u00e9e<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5b8abdeb\">S'il est indiqu\u00e9 que le serveur prend en charge un module SFP optique 1G standard, testez un chemin optique 1000BASE-X dont le bon fonctionnement est av\u00e9r\u00e9 et qui est correctement adapt\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f76c2683\">Si ce chemin fonctionne mais que le module actif cible ne fonctionne pas, le r\u00e9sultat permet de circonscrire le probl\u00e8me au mode, \u00e0 l'alimentation, au codage, au micrologiciel ou aux exigences de service du p\u00e9riph\u00e9rique cible. Il ne permet toutefois pas d'identifier pr\u00e9cis\u00e9ment la cause sans \u00e9l\u00e9ments suppl\u00e9mentaires.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f379f0bd\">Modifiez un composant ou un param\u00e8tre \u00e0 la fois et notez l'\u00e9tat de la liaison et le d\u00e9bit obtenus.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-87916523\">Comment cela s'applique-t-il \u00e0 un LuLeey ? <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/fr\/tag\/media-converter\/\" title=\"Voir tous les messages dans MEDIA CONVERTER\">CONVERTISSEUR DE M\u00c9DIAS<\/a><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3e810598\">Le <a href=\"https:\/\/www.luleey.com\/fr\/produit-2\/1000m-sfp-media-converter\/?utm_source=chatgpt.com\">Convertisseur de m\u00e9dia Gigabit SFP LuLeey<\/a> Cette page mentionne un port RJ45 10\/100\/1000 M et un emplacement SFP 1000 M destin\u00e9 aux modules SFP 1,25 G compatibles. Pour les cas d'utilisation sp\u00e9cifiques de la cl\u00e9 GPON, il est explicitement demand\u00e9 aux utilisateurs de v\u00e9rifier si la cl\u00e9 n\u00e9cessite le mode h\u00f4te SGMII ou 1000BASE-X.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-54670d15\">Il s'agit d'un point de contr\u00f4le de compatibilit\u00e9, et non d'une garantie que chaque Stick fonctionnera. La page ne propose pas de tableau r\u00e9pertoriant tous les Stick, toutes les r\u00e9visions mat\u00e9rielles, tous les micrologiciels et tous les modes d'interface.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a06cfbd5\">Avant l'achat ou le d\u00e9ploiement, veuillez indiquer \u00e0 LuLeey le mod\u00e8le exact du Stick, la r\u00e9vision mat\u00e9rielle, la version du micrologiciel, le d\u00e9bit h\u00f4te souhait\u00e9 et le mode d'interface requis.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-eb46f5a5\">Pour en savoir plus sur le processus d\u00e9cisionnel dans son ensemble, voir <a href=\"https:\/\/www.luleey.com\/fr\/can-a-pon-onu-stick-work-in-an-sfp-media-converter\/?utm_source=chatgpt.com\">Une cl\u00e9 ONU PON peut-elle fonctionner dans un convertisseur de m\u00e9dia SFP ?<\/a>. Si ce qui pr\u00eate \u00e0 confusion, c'est le lieu o\u00f9 se d\u00e9roule la n\u00e9gociation, utilisez <a href=\"https:\/\/www.luleey.com\/fr\/sfp-auto-negotiation-do-modules-select-speed\/?utm_source=chatgpt.com\">N\u00e9gociation automatique SFP : les modules choisissent-ils la vitesse ?<\/a> en guise de guide d'accompagnement.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-c4dc4259\">R\u00e9f\u00e9rences faisant autorit\u00e9<\/h3>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li><a href=\"https:\/\/standards.ieee.org\/ieee\/802.3\/10422\/?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">IEEE 802.3-2022 \u2014 Norme IEEE relative \u00e0 Ethernet<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/docs.kernel.org\/networking\/phy.html\" target=\"_blank\" rel=\"noopener\">Noyau Linux \u2014 Couche d'abstraction PHY<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/ww1.microchip.com\/downloads\/aemDocuments\/documents\/UNG\/ApplicationNotes\/ApplicationNotes\/AN5485-Interfacing-the-SGMII-Port-on-LAN9646-Switch-DS00005485.pdf?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Microchip AN5485 \u2014 Interfa\u00e7age du port SGMII sur le commutateur LAN9646<\/a><\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>Consultez la norme SGMII 1000BASE-X. Fonction principale : interface s\u00e9rie entre un MAC et un PHY. Mode PCS\/liaison Gigabit Ethernet IEEE 802.3 utilis\u00e9.<\/p>","protected":false},"author":1,"featured_media":23201,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[887],"tags":[51,1757,1783,1782,1640,1467,1781],"class_list":["post-23199","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-data-transmission-conversion","tag-media-converter","tag-1000base-x","tag-clause-37","tag-host-serdes","tag-onu-stick","tag-sfp-compatibility","tag-sgmii"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/posts\/23199","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/comments?post=23199"}],"version-history":[{"count":1,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/posts\/23199\/revisions"}],"predecessor-version":[{"id":23256,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/posts\/23199\/revisions\/23256"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/media\/23201"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/media?parent=23199"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/categories?post=23199"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/tags?post=23199"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}