{"id":16612,"date":"2024-12-15T14:42:33","date_gmt":"2024-12-15T06:42:33","guid":{"rendered":"https:\/\/www.luleey.com\/?post_type=product&#038;p=16612"},"modified":"2026-10-03T22:41:12","modified_gmt":"2026-10-03T14:41:12","slug":"8xsfp-l2-web-managed-switch","status":"publish","type":"product","link":"https:\/\/www.luleey.com\/fr\/produit-2\/8xsfp-l2-web-managed-switch\/","title":{"rendered":"Commutateur g\u00e9r\u00e9 10G SFP+ \u00e0 8 ports, commutateur g\u00e9r\u00e9 de couche 2+, gestion via le Web sans ventilateur"},"content":{"rendered":"<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1ajqw0r\" data-start=\"2448\" data-end=\"2491\">Pr\u00e9sentation du commutateur g\u00e9r\u00e9 10G SFP+ \u00e0 8 ports<\/h3>\n<p data-start=\"2493\" data-end=\"2637\">Le <strong data-start=\"2497\" data-end=\"2531\">Commutateur g\u00e9r\u00e9 \u00e0 8 ports 10G SFP+<\/strong> Il offre huit emplacements SFP+ haut d\u00e9bit permettant de mettre en place des r\u00e9seaux compacts en fibre optique \u00e0 10 Gbit\/s et des r\u00e9seaux en cuivre \u00e0 connexion directe.<\/p>\n<p data-start=\"2639\" data-end=\"2879\">Avec une capacit\u00e9 de commutation de 160 Gbps et un d\u00e9bit de transfert de 119,04 Mpps, ce commutateur est con\u00e7u pour g\u00e9rer simultan\u00e9ment un trafic \u00e0 haut d\u00e9bit entre des serveurs, des syst\u00e8mes NAS, des p\u00e9riph\u00e9riques de stockage, des postes de travail, des routeurs et d'autres commutateurs r\u00e9seau.<\/p>\n<p data-start=\"2881\" data-end=\"3241\">L'interface de gestion Web prend en charge les fonctions de couche 2 couramment utilis\u00e9es, notamment les VLAN 802.1Q, l'agr\u00e9gation de liaisons, le protocole LACP, la mise en miroir des ports, le contr\u00f4le des temp\u00eates, le protocole Spanning Tree, le protocole RSTP, la gestion de la multidiffusion, la qualit\u00e9 de service (QoS), la surveillance DHCP et le protocole SNMP. Ces fonctions permettent aux administrateurs de segmenter les r\u00e9seaux, de regrouper plusieurs liaisons, de hi\u00e9rarchiser le trafic important et de surveiller l'activit\u00e9 des ports.<\/p>\n<p data-start=\"3243\" data-end=\"3482\">Les huit emplacements SFP+ prennent en charge les modules 10G compatibles ainsi que certains modules 1G ou 2,5G. Une configuration de la vitesse des ports peut s'av\u00e9rer n\u00e9cessaire en cas d'utilisation de modules SFP \u00e0 d\u00e9bit inf\u00e9rieur ; il convient donc de v\u00e9rifier le type de module et le mod\u00e8le de l'\u00e9quipement avant le d\u00e9ploiement.<\/p>\n<p data-start=\"3484\" data-end=\"3687\">Un bo\u00eetier m\u00e9tallique sans ventilateur garantit un fonctionnement silencieux et une dissipation thermique passive, ce qui rend ce commutateur id\u00e9al pour les bureaux, les laboratoires \u00e0 domicile, les salles techniques, les r\u00e9seaux NAS et tout autre environnement sensible au bruit.<\/p>\n<h3 data-section-id=\"1iz91iu\" data-start=\"3689\" data-end=\"3705\">Caract\u00e9ristiques principales<\/h3>\n<ul data-start=\"3707\" data-end=\"4140\">\n<li data-section-id=\"fz4nz7\" data-start=\"3707\" data-end=\"3744\">Huit ports r\u00e9seau SFP+ \u00e0 d\u00e9bits multiples<\/li>\n<li data-section-id=\"1lauaoe\" data-start=\"3745\" data-end=\"3785\">Compatible avec les d\u00e9bits 1G, 2,5G et 10G<\/li>\n<li data-section-id=\"s7yo8v\" data-start=\"3786\" data-end=\"3814\">Capacit\u00e9 de commutation de 160 Gbps<\/li>\n<li data-section-id=\"uq5lpi\" data-start=\"3815\" data-end=\"3850\">D\u00e9bit de transfert de 119,04 Mpps<\/li>\n<li data-section-id=\"1h7rjgx\" data-start=\"3851\" data-end=\"3873\">Tampon de paquets de 12 Mbit<\/li>\n<li data-section-id=\"laknc3\" data-start=\"3874\" data-end=\"3897\">Table d'adresses MAC de 16 Ko<\/li>\n<li data-section-id=\"149j4oz\" data-start=\"3898\" data-end=\"3921\">Jusqu'\u00e0 4 000 VLAN actifs<\/li>\n<li data-section-id=\"punzkq\" data-start=\"3922\" data-end=\"3946\">Gestion des VLAN 802.1Q<\/li>\n<li data-section-id=\"1c6pivl\" data-start=\"3947\" data-end=\"3974\">Agr\u00e9gation de liaisons et LACP<\/li>\n<li data-section-id=\"19mrjwe\" data-start=\"3975\" data-end=\"3997\">Prise en charge des protocoles STP et RSTP<\/li>\n<li data-section-id=\"139ebma\" data-start=\"3998\" data-end=\"4028\">Gestion de la qualit\u00e9 de service (QoS) et de la bande passante<\/li>\n<li data-section-id=\"136d5kj\" data-start=\"4029\" data-end=\"4063\">Mise en miroir des ports et contr\u00f4le des temp\u00eates<\/li>\n<li data-section-id=\"fe1lzl\" data-start=\"4064\" data-end=\"4088\">Surveillance DHCP et SNMP<\/li>\n<li data-section-id=\"1sp3lab\" data-start=\"4089\" data-end=\"4114\">Bo\u00eetier m\u00e9tallique sans ventilateur<\/li>\n<li data-section-id=\"6l1z2s\" data-start=\"4115\" data-end=\"4140\">Configuration via le Web<\/li>\n<\/ul>\n<h3 data-section-id=\"wggvqn\" data-start=\"4142\" data-end=\"4158\">Applications<\/h3>\n<ul data-start=\"4160\" data-end=\"4449\">\n<li data-section-id=\"1ijjz8t\" data-start=\"4160\" data-end=\"4190\">NAS 10G et r\u00e9seaux de stockage<\/li>\n<li data-section-id=\"dkr7wh\" data-start=\"4191\" data-end=\"4221\">Connexions entre le serveur et le commutateur<\/li>\n<li data-section-id=\"11au4t2\" data-start=\"4222\" data-end=\"4242\">Agr\u00e9gation de commutateurs<\/li>\n<li data-section-id=\"1o18vvp\" data-start=\"4243\" data-end=\"4262\">R\u00e9seaux domestiques<\/li>\n<li data-section-id=\"9oxqoo\" data-start=\"4263\" data-end=\"4292\">Salles de serveurs pour petites entreprises<\/li>\n<li data-section-id=\"1xqt1l6\" data-start=\"4293\" data-end=\"4324\">Syst\u00e8mes de stockage pour le montage vid\u00e9o<\/li>\n<li data-section-id=\"14e0ye2\" data-start=\"4325\" data-end=\"4358\">R\u00e9seaux de postes de travail \u00e0 haut d\u00e9bit<\/li>\n<li data-section-id=\"12hy992\" data-start=\"4359\" data-end=\"4387\">R\u00e9seau de distribution par fibre optique<\/li>\n<li data-section-id=\"l8ugd\" data-start=\"4388\" data-end=\"4418\">Connexions des baies de centre de donn\u00e9es<\/li>\n<li data-section-id=\"myymrp\" data-start=\"4419\" data-end=\"4449\">Laboratoires d'essais de r\u00e9seaux<\/li>\n<\/ul>\n<h2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1lape25\" data-start=\"4588\" data-end=\"4617\">Caract\u00e9ristiques techniques<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"4619\" data-end=\"5480\">\n<thead data-start=\"4619\" data-end=\"4648\">\n<tr data-start=\"4619\" data-end=\"4648\">\n<th class=\"last:pe-10\" data-start=\"4619\" data-end=\"4631\" data-col-size=\"sm\">Param\u00e8tres<\/th>\n<th class=\"last:pe-10\" data-start=\"4631\" data-end=\"4648\" data-col-size=\"md\">Sp\u00e9cifications<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"4659\" data-end=\"5480\">\n<tr data-start=\"4659\" data-end=\"4677\">\n<td data-start=\"4659\" data-end=\"4667\" data-col-size=\"sm\">Marque<\/td>\n<td data-start=\"4667\" data-end=\"4677\" data-col-size=\"md\">Luleey<\/td>\n<\/tr>\n<tr data-start=\"4678\" data-end=\"4705\">\n<td data-start=\"4678\" data-end=\"4686\" data-col-size=\"sm\">Mod\u00e8le<\/td>\n<td data-start=\"4686\" data-end=\"4705\" data-col-size=\"md\">LL-L2+MES-8SFP+<\/td>\n<\/tr>\n<tr data-start=\"4706\" data-end=\"4751\">\n<td data-start=\"4706\" data-end=\"4721\" data-col-size=\"sm\">Type de produit<\/td>\n<td data-start=\"4721\" data-end=\"4751\" data-col-size=\"md\">Commutateur r\u00e9seau g\u00e9r\u00e9 via le Web<\/td>\n<\/tr>\n<tr data-start=\"4752\" data-end=\"4786\">\n<td data-start=\"4752\" data-end=\"4768\" data-col-size=\"sm\">Ports r\u00e9seau<\/td>\n<td data-start=\"4768\" data-end=\"4786\" data-col-size=\"md\">8 emplacements SFP+<\/td>\n<\/tr>\n<tr data-start=\"4787\" data-end=\"4829\">\n<td data-start=\"4787\" data-end=\"4810\" data-col-size=\"sm\">Tarifs des ports pris en charge<\/td>\n<td data-start=\"4810\" data-end=\"4829\" data-col-size=\"md\">1G \/ 2,5G \/ 10G<\/td>\n<\/tr>\n<tr data-start=\"4830\" data-end=\"4862\">\n<td data-start=\"4830\" data-end=\"4851\" data-col-size=\"sm\">Capacit\u00e9 de commutation<\/td>\n<td data-start=\"4851\" data-end=\"4862\" data-col-size=\"md\">160Gbps<\/td>\n<\/tr>\n<tr data-start=\"4863\" data-end=\"4902\">\n<td data-start=\"4863\" data-end=\"4888\" data-col-size=\"sm\">Taux de transmission des paquets<\/td>\n<td data-start=\"4888\" data-end=\"4902\" data-col-size=\"md\">119.04Mpps<\/td>\n<\/tr>\n<tr data-start=\"4903\" data-end=\"4929\">\n<td data-start=\"4903\" data-end=\"4919\" data-col-size=\"sm\">Tampon de paquets<\/td>\n<td data-start=\"4919\" data-end=\"4929\" data-col-size=\"md\">12Mbit<\/td>\n<\/tr>\n<tr data-start=\"4930\" data-end=\"4957\">\n<td data-start=\"4930\" data-end=\"4950\" data-col-size=\"sm\">Table des adresses MAC<\/td>\n<td data-start=\"4950\" data-end=\"4957\" data-col-size=\"md\">16K<\/td>\n<\/tr>\n<tr data-start=\"4958\" data-end=\"4984\">\n<td data-start=\"4958\" data-end=\"4974\" data-col-size=\"sm\">Plage d'identifiants VLAN<\/td>\n<td data-start=\"4974\" data-end=\"4984\" data-col-size=\"md\">1\u20134094<\/td>\n<\/tr>\n<tr data-start=\"4985\" data-end=\"5014\">\n<td data-start=\"4985\" data-end=\"5008\" data-col-size=\"sm\">Nombre maximal de VLAN actifs<\/td>\n<td data-start=\"5008\" data-end=\"5014\" data-col-size=\"md\">4K<\/td>\n<\/tr>\n<tr data-start=\"5015\" data-end=\"5051\">\n<td data-start=\"5015\" data-end=\"5032\" data-col-size=\"sm\">Puce de commutation<\/td>\n<td data-start=\"5032\" data-end=\"5051\" data-col-size=\"md\">Realtek RTL9303<\/td>\n<\/tr>\n<tr data-start=\"5052\" data-end=\"5082\">\n<td data-start=\"5052\" data-end=\"5065\" data-col-size=\"sm\">Gestion<\/td>\n<td data-start=\"5065\" data-end=\"5082\" data-col-size=\"md\">Interface Web<\/td>\n<\/tr>\n<tr data-start=\"5083\" data-end=\"5163\">\n<td data-start=\"5083\" data-end=\"5103\" data-col-size=\"sm\">Fonctions de la couche 2<\/td>\n<td data-start=\"5103\" data-end=\"5163\" data-col-size=\"md\">VLAN, LACP, STP\/RSTP, QoS, mise en miroir de ports, contr\u00f4le des temp\u00eates<\/td>\n<\/tr>\n<tr data-start=\"5164\" data-end=\"5235\">\n<td data-start=\"5164\" data-end=\"5190\" data-col-size=\"sm\">Surveillance et s\u00e9curit\u00e9<\/td>\n<td data-start=\"5190\" data-end=\"5235\" data-col-size=\"md\">SNMP, surveillance DHCP, gestion de la multidiffusion<\/td>\n<\/tr>\n<tr data-start=\"5236\" data-end=\"5257\">\n<td data-start=\"5236\" data-end=\"5246\" data-col-size=\"sm\">Refroidissement<\/td>\n<td data-start=\"5246\" data-end=\"5257\" data-col-size=\"md\">Sans ventilateur<\/td>\n<\/tr>\n<tr data-start=\"5258\" data-end=\"5277\">\n<td data-start=\"5258\" data-end=\"5268\" data-col-size=\"sm\">Logement<\/td>\n<td data-start=\"5268\" data-end=\"5277\" data-col-size=\"md\">M\u00e9tal<\/td>\n<\/tr>\n<tr data-start=\"5278\" data-end=\"5305\">\n<td data-start=\"5278\" data-end=\"5292\" data-col-size=\"sm\">Entr\u00e9e d'alimentation<\/td>\n<td data-start=\"5292\" data-end=\"5305\" data-col-size=\"md\">12 V CC, 2 A<\/td>\n<\/tr>\n<tr data-start=\"5306\" data-end=\"5345\">\n<td data-start=\"5306\" data-end=\"5330\" data-col-size=\"sm\">Temp\u00e9rature de fonctionnement<\/td>\n<td data-start=\"5330\" data-end=\"5345\" data-col-size=\"md\">de 0 \u00b0C \u00e0 40 \u00b0C<\/td>\n<\/tr>\n<tr data-start=\"5346\" data-end=\"5385\">\n<td data-start=\"5346\" data-end=\"5368\" data-col-size=\"sm\">Temp\u00e9rature de stockage<\/td>\n<td data-start=\"5368\" data-end=\"5385\" data-col-size=\"md\">de -40 \u00b0C \u00e0 70 \u00b0C<\/td>\n<\/tr>\n<tr data-start=\"5386\" data-end=\"5434\">\n<td data-start=\"5386\" data-end=\"5407\" data-col-size=\"sm\">Humidit\u00e9 de fonctionnement<\/td>\n<td data-start=\"5407\" data-end=\"5434\" data-col-size=\"md\">10%\u201390%, sans condensation<\/td>\n<\/tr>\n<tr data-start=\"5435\" data-end=\"5480\">\n<td data-start=\"5435\" data-end=\"5454\" data-col-size=\"sm\">Humidit\u00e9 de stockage<\/td>\n<td data-start=\"5454\" data-end=\"5480\" data-col-size=\"md\">5%\u201395%, sans condensation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"1726\" data-end=\"1882\">Le Luleey <strong data-start=\"1737\" data-end=\"1771\">Commutateur g\u00e9r\u00e9 \u00e0 8 ports 10G SFP+<\/strong> Il offre huit ports SFP+ \u00e0 d\u00e9bits multiples, une capacit\u00e9 de commutation de 160 Gbit\/s et une gestion Web sans ventilateur pour les r\u00e9seaux 10G.<\/p>\n<ul data-start=\"1884\" data-end=\"2328\">\n<li data-section-id=\"1x2unyi\" data-start=\"1884\" data-end=\"1941\">Huit emplacements SFP+ pour des connexions r\u00e9seau \u00e0 haut d\u00e9bit<\/li>\n<li data-section-id=\"1s30255\" data-start=\"1942\" data-end=\"2004\">Prend en charge les modules optiques ou DAC compatibles 1G, 2,5G et 10G<\/li>\n<li data-section-id=\"s7yo8v\" data-start=\"2005\" data-end=\"2033\">Capacit\u00e9 de commutation de 160 Gbps<\/li>\n<li data-section-id=\"1e4ogfo\" data-start=\"2034\" data-end=\"2069\">D\u00e9bit de transfert de paquets de 119,04 Mpps<\/li>\n<li data-section-id=\"kka4mp\" data-start=\"2070\" data-end=\"2118\">Tampon de paquets de 12 Mbit et table d'adresses MAC de 16 Ko<\/li>\n<li data-section-id=\"16covot\" data-start=\"2119\" data-end=\"2182\">Gestion Web des VLAN, du LACP, de la QoS, du RSTP et de la surveillance des ports<\/li>\n<li data-section-id=\"18cj99m\" data-start=\"2183\" data-end=\"2226\">Bo\u00eetier m\u00e9tallique sans ventilateur pour un fonctionnement silencieux<\/li>\n<li data-section-id=\"1s9fzil\" data-start=\"2227\" data-end=\"2288\">Convient aux NAS, serveurs, syst\u00e8mes de stockage, commutateurs et laboratoires \u00e0 domicile<\/li>\n<li data-section-id=\"10i8hf6\" data-start=\"2289\" data-end=\"2328\">Options de prises \u00e9lectriques pour l'UE, les \u00c9tats-Unis, le Royaume-Uni et l'Afrique du Sud<\/li>\n<\/ul>","protected":false},"featured_media":16613,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[258],"product_tag":[791,322],"class_list":["post-16612","product","type-product","status-publish","has-post-thumbnail","product_cat-managed-switches","product_tag-managed-switch","product_tag-sfp","first","instock","shipping-taxable","purchasable","product-type-variable","has-default-attributes"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/product\/16612","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/comments?post=16612"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/media\/16613"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/media?parent=16612"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/product_brand?post=16612"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/product_cat?post=16612"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/product_tag?post=16612"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}