{"id":21443,"date":"2026-07-26T18:00:10","date_gmt":"2026-07-26T10:00:10","guid":{"rendered":"https:\/\/www.luleey.com\/?post_type=product&#038;p=21443"},"modified":"2026-07-26T18:09:11","modified_gmt":"2026-07-26T10:09:11","slug":"fc-upc-fixed-fiber-optic-attenuator-single-mode-optical-attenuator-0db-to-30db","status":"publish","type":"product","link":"https:\/\/www.luleey.com\/fr\/produit-2\/fc-upc-fixed-fiber-optic-attenuator-single-mode-optical-attenuator-0db-to-30db\/","title":{"rendered":"FC UPC Fixed Fiber Optic Attenuator, Single Mode Optical Attenuator 0dB to 30dB"},"content":{"rendered":"<h2>Pr\u00e9sentation du produit<\/h2>\n<p>The Luleey FC UPC Fixed Fiber Optic Attenuator is a passive optical component used to reduce optical signal power by a fixed attenuation value in single mode fiber networks. It is commonly used when the received optical power is too strong for the optical receiver, or when engineers need to balance link budgets during installation, testing, and maintenance.<\/p>\n<p>This FC UPC Attenuator is suitable for telecom rooms, ODF systems, optical transceivers, media converters, switches, routers, servers, storage devices, fiber test equipment, and general single mode optical communication links.<\/p>\n<p>Compared with APC attenuators, FC\/UPC attenuators are better suited for general optical links, lab testing, data communication systems, transceiver testing, and equipment connections where UPC interfaces are already used. If your fiber equipment, patch cable, or adapter is FC\/UPC, this FC UPC Fixed Fiber Optic Attenuator is the correct matching connector type.<\/p>\n<p>Luleey provides multiple fixed attenuation values from 0dB to 30dB, helping installers and network engineers select the proper optical power reduction value for different fiber link requirements.<\/p>\n<h2>Caract\u00e9ristiques<\/h2>\n<ul>\n<li>FC UPC Fixed Fiber Optic Attenuator for single mode fiber networks<\/li>\n<li>Fixed attenuation values for stable optical power reduction<\/li>\n<li>FC\/UPC connector for general single mode optical links<\/li>\n<li>Available attenuation range from 0dB to 30dB fixed values<\/li>\n<li>Helps protect optical receivers from excessive input power<\/li>\n<li>Helps balance optical link budget in telecom, ODF, data communication, and fiber testing systems<\/li>\n<li>Suitable for optical transceiver testing and receiver power adjustment<\/li>\n<li>Low insertion loss and good repeatability<\/li>\n<li>Plug-and-play passive optical component<\/li>\n<li>Reusable design for installation, testing, and maintenance<\/li>\n<li>Suitable for switches, routers, media converters, optical transceivers, servers, fiber NICs, storage devices, and test tools<\/li>\n<li>Factory tested by Luleey for practical optical network deployment<\/li>\n<\/ul>\n<h2>Applications<\/h2>\n<ul>\n<li>Telecom Room Fiber Links<\/li>\n<li>ODF Optical Distribution<\/li>\n<li>Optical Power Adjustment<\/li>\n<li>Fiber Link Budget Balancing<\/li>\n<li>Optical Receiver Protection<\/li>\n<li>Fiber Testing and Maintenance<\/li>\n<li>Optical Transceiver Testing<\/li>\n<li>Media Converter Deployment<\/li>\n<li>Switch and Router Fiber Links<\/li>\n<li>Server and Storage Fiber Connections<\/li>\n<li>Data Communication Systems<\/li>\n<li>Laboratory Optical Testing<\/li>\n<li>General Single Mode Fiber Networks<\/li>\n<\/ul>\n<h2>Sp\u00e9cifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Param\u00e8tres<\/th>\n<th>Valeur<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marque<\/td>\n<td>Luleey<\/td>\n<\/tr>\n<tr>\n<td>Type de produit<\/td>\n<td>FC UPC Fixed Fiber Optic Attenuator<\/td>\n<\/tr>\n<tr>\n<td>Type de connecteur<\/td>\n<td>FC\/UPC<\/td>\n<\/tr>\n<tr>\n<td>Type d'att\u00e9nuateur<\/td>\n<td>Valeur fixe<\/td>\n<\/tr>\n<tr>\n<td>Type de fibre<\/td>\n<td>Fibre monomode<\/td>\n<\/tr>\n<tr>\n<td>Valeurs d'att\u00e9nuation disponibles<\/td>\n<td>0 dB, 1 dB, 2 dB, 3 dB, 4 dB, 5 dB, 6 dB, 7 dB, 8 dB, 9 dB, 10 dB, 11 dB, 12 dB, 13 dB, 14 dB, 15 dB, 16 dB, 17 dB, 18 dB, 19 dB, 20 dB, 25 dB, 27 dB, 30 dB<\/td>\n<\/tr>\n<tr>\n<td>Plage d'att\u00e9nuation<\/td>\n<td>Valeurs fixes comprises entre 0 dB et 30 dB<\/td>\n<\/tr>\n<tr>\n<td>Utilisation type<\/td>\n<td>R\u00e9duction de la puissance du signal optique et ajustement du budget de liaison<\/td>\n<\/tr>\n<tr>\n<td>Perte de retour<\/td>\n<td>Conception \u00e0 forte perte de retour<\/td>\n<\/tr>\n<tr>\n<td>Perte d'insertion<\/td>\n<td>Conception \u00e0 faible perte d'insertion<\/td>\n<\/tr>\n<tr>\n<td>Durabilit\u00e9 des modules enfichables<\/td>\n<td>Plus de 1 000 fois<\/td>\n<\/tr>\n<tr>\n<td>\u00c9quipement d'application<\/td>\n<td>\u00c9metteurs-r\u00e9cepteurs optiques, commutateurs, routeurs, convertisseurs de m\u00e9dia, serveurs, cartes r\u00e9seau \u00e0 fibre optique, p\u00e9riph\u00e9riques de stockage, \u00e9quipements de test optique<\/td>\n<\/tr>\n<tr>\n<td>Application r\u00e9seau<\/td>\n<td>Telecom, ODF, optical distribution, data communication, fiber testing<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Why Use an FC UPC Fiber Optic Attenuator?<\/h2>\n<p>A fiber optic attenuator is used when the optical signal power is too high for the receiving device. Too much optical power may overload the receiver and cause unstable links, device alarms, packet loss, or poor performance.<\/p>\n<p>A fixed attenuator helps:<\/p>\n<ul>\n<li>Reduce excessive optical power<\/li>\n<li>Protect optical receivers<\/li>\n<li>Balance optical link budgets<\/li>\n<li>Prevent receiver overload<\/li>\n<li>Improve link stability<\/li>\n<li>Support fiber testing and troubleshooting<\/li>\n<li>Simulate fiber loss in lab environments<\/li>\n<li>Match optical power requirements between different devices<\/li>\n<\/ul>\n<p>For data communication, optical transceiver testing, telecom, ODF, and general single mode fiber applications, the Luleey FC UPC Fixed Fiber Optic Attenuator is a practical passive component for optical power control.<\/p>\n<h2>FC UPC vs FC APC Attenuator<\/h2>\n<p>FC UPC and FC APC attenuators use different connector end-face structures. They should be selected according to the actual connector type used by the equipment and patch cable.<\/p>\n<table>\n<thead>\n<tr>\n<th>Type de connecteur<\/th>\n<th>Meilleur pour<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Att\u00e9nuateur FC UPC<\/td>\n<td>General single mode optical links, optical transceiver testing, test equipment, data communication systems<\/td>\n<\/tr>\n<tr>\n<td>Att\u00e9nuateur FC APC<\/td>\n<td>Low-reflection single mode links, FTTH, CATV, PON, telecom, optical distribution systems<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Choose FC\/UPC when the connected device, patch cable, adapter, or test equipment also uses FC\/UPC.<\/p>\n<p>Choose FC\/APC when the fiber line or optical equipment requires APC angled polish and lower back reflection.<\/p>\n<p>Do not directly mix UPC and APC connector end-faces, because this may cause poor contact, higher loss, stronger reflection, and unstable optical performance.<\/p>\n<h2>How to Choose the Right Attenuation Value<\/h2>\n<p>The correct attenuation value depends on the optical receiver input range and the actual received optical power. Before choosing the dB value, measure the current optical power with an optical power meter.<\/p>\n<table>\n<thead>\n<tr>\n<th>Valeur d'att\u00e9nuation<\/th>\n<th>Utilisation type<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0dB<\/td>\n<td>Connexion de r\u00e9f\u00e9rence, essais sp\u00e9cifiques, adaptation de connexion ou absence d'att\u00e9nuation intentionnelle<\/td>\n<\/tr>\n<tr>\n<td>de 1 dB \u00e0 3 dB<\/td>\n<td>L\u00e9g\u00e8re correction de la puissance optique<\/td>\n<\/tr>\n<tr>\n<td>de 4 dB \u00e0 7 dB<\/td>\n<td>R\u00e9duction mod\u00e9r\u00e9e de la puissance optique<\/td>\n<\/tr>\n<tr>\n<td>de 8 dB \u00e0 12 dB<\/td>\n<td>R\u00e9duction plus importante de la puissance optique pour les signaux re\u00e7us puissants<\/td>\n<\/tr>\n<tr>\n<td>de 13 dB \u00e0 20 dB<\/td>\n<td>Att\u00e9nuation importante pour les liaisons courtes, la r\u00e9gulation d'une puissance d'entr\u00e9e \u00e9lev\u00e9e ou la protection du r\u00e9cepteur<\/td>\n<\/tr>\n<tr>\n<td>25 dB \/ 27 dB \/ 30 dB<\/td>\n<td>Att\u00e9nuation tr\u00e8s importante pour les essais en laboratoire, les liaisons optiques \u00e0 haute puissance ou la simulation de budget de liaison<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The selected attenuator should reduce the received optical power into a safe and stable operating range.<\/p>","protected":false},"excerpt":{"rendered":"<p class=\"isSelectedEnd\">The Luleey FC UPC Fixed Fiber Optic Attenuator is designed to reduce optical signal power in single mode fiber networks with stable fixed attenuation values from 0dB to 30dB, helping protect optical receivers, balance link budgets, and optimize signal levels in telecom, data communication, fiber testing, ODF, and optical transceiver applications.<\/p>\n<ul data-spread=\"false\">\n<li>FC\/UPC connector for general single mode fiber networks<\/li>\n<li>Valeurs fixes disponibles : 0 dB, 1 dB, 2 dB, 3 dB, 4 dB, 5 dB, 6 dB, 7 dB, 8 dB, 9 dB, 10 dB, 11 dB, 12 dB, 13 dB, 14 dB, 15 dB, 16 dB, 17 dB, 18 dB, 19 dB, 20 dB, 25 dB, 27 dB, 30 dB<\/li>\n<li>Contribue \u00e0 r\u00e9duire la puissance optique excessive et \u00e0 compenser les pertes sur la liaison par fibre optique<\/li>\n<li>UPC polish is suitable for general optical links, test equipment, transceivers, and data communication systems<\/li>\n<li>L'option 0 dB peut \u00eatre utilis\u00e9e pour une connexion de r\u00e9f\u00e9rence ou pour des applications de test sp\u00e9cifiques<\/li>\n<li>Les options 25 dB, 27 dB et 30 dB conviennent \u00e0 une r\u00e9duction importante de la puissance optique ou \u00e0 la simulation en laboratoire<\/li>\n<li>Convient aux \u00e9metteurs-r\u00e9cepteurs optiques, aux convertisseurs de m\u00e9dia, aux commutateurs, aux routeurs, aux serveurs, aux cartes r\u00e9seau fibre optique, aux p\u00e9riph\u00e9riques de stockage et aux \u00e9quipements de test optique<\/li>\n<\/ul>","protected":false},"featured_media":21445,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[788],"product_tag":[402,395,1299,1291,1292,1297,1293,1179,1298],"class_list":["post-21443","product","type-product","status-publish","has-post-thumbnail","product_cat-optical-attenuator","product_tag-attenuator","product_tag-fc-upc-attenuator","product_tag-fiber-attenuator","product_tag-fiber-optic-attenuator","product_tag-fixed-attenuator","product_tag-fixed-fiber-optic-attenuator","product_tag-optical-attenuator","product_tag-single-mode-fiber","product_tag-single-mode-optical-attenuator","first","instock","shipping-taxable","purchasable","product-type-variable","has-default-attributes"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/product\/21443","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/comments?post=21443"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/media\/21445"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/media?parent=21443"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/product_brand?post=21443"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/product_cat?post=21443"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/product_tag?post=21443"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}