{"id":21451,"date":"2026-07-26T19:52:30","date_gmt":"2026-07-26T11:52:30","guid":{"rendered":"https:\/\/www.luleey.com\/?post_type=product&#038;p=21451"},"modified":"2026-07-26T19:56:24","modified_gmt":"2026-07-26T11:56:24","slug":"sc-upc-fixed-fiber-optic-attenuator-single-mode-optical-attenuator-0db-to-30db","status":"publish","type":"product","link":"https:\/\/www.luleey.com\/fr\/produit-2\/sc-upc-fixed-fiber-optic-attenuator-single-mode-optical-attenuator-0db-to-30db\/","title":{"rendered":"SC UPC Fixed Fiber Optic Attenuator, Single Mode Optical Attenuator 0dB to 30dB"},"content":{"rendered":"<h2>Pr\u00e9sentation du produit<\/h2>\n<p>The Luleey SC UPC Fixed Fiber Optic Attenuator is a passive optical component designed to reduce optical signal power by a fixed attenuation value in single mode fiber networks. It is commonly used when the received optical power is too strong for the optical receiver, or when engineers need to balance link budgets during installation, testing, and maintenance.<\/p>\n<p>This SC UPC Attenuator is suitable for FTTH, FTTX, CATV, telecom rooms, ODF systems, PON networks, fiber testing, optical transceivers, media converters, switches, routers, servers, storage devices, and optical network maintenance.<\/p>\n<p>The SC\/UPC connector uses an angled polish structure, making it suitable for low-reflection single mode optical systems. Compared with UPC connectors, UPC connectors are more commonly used in FTTH, CATV, PON, and optical distribution environments where return loss performance is important.<\/p>\n<p>Luleey provides multiple fixed attenuation values from 0dB to 30dB, helping installers and network engineers select the proper signal reduction value for different optical link requirements.<\/p>\n<h2>Caract\u00e9ristiques<\/h2>\n<ul>\n<li>SC UPC Fixed Fiber Optic Attenuator for single mode fiber networks<\/li>\n<li>Fixed attenuation values for stable optical power reduction<\/li>\n<li>SC\/UPC connector for low-reflection optical links<\/li>\n<li>Available attenuation range from 0dB to 30dB fixed values<\/li>\n<li>Helps protect optical receivers from excessive input power<\/li>\n<li>Helps balance optical link budget in FTTH, CATV, telecom, and PON networks<\/li>\n<li>Suitable for 1310nm and 1550nm single mode applications<\/li>\n<li>High return loss design for stable optical performance<\/li>\n<li>Low insertion loss and good repeatability<\/li>\n<li>Good wear resistance for repeated connection<\/li>\n<li>Plug-and-play passive optical component<\/li>\n<li>Suitable for fiber switches, routers, media converters, optical transceivers, servers, fiber NICs, storage devices, and test equipment<\/li>\n<li>Useful for optical network deployment, troubleshooting, maintenance, and lab testing<\/li>\n<\/ul>\n<h2>Applications<\/h2>\n<ul>\n<li>FTTH Fiber Networks<\/li>\n<li>FTTX Access Networks<\/li>\n<li>CATV Optical Systems<\/li>\n<li>PON Optical Networks<\/li>\n<li>Telecom Room Fiber Links<\/li>\n<li>ODF Optical Distribution<\/li>\n<li>Optical Power Adjustment<\/li>\n<li>Fiber Link Budget Balancing<\/li>\n<li>Optical Receiver Protection<\/li>\n<li>Fiber Testing and Maintenance<\/li>\n<li>Optical Transceiver Testing<\/li>\n<li>Media Converter Deployment<\/li>\n<li>Switch and Router Fiber Links<\/li>\n<li>Server and Storage Fiber Connections<\/li>\n<li>Laboratory Optical Testing<\/li>\n<\/ul>\n<h2>Sp\u00e9cifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Param\u00e8tres<\/th>\n<th>Valeur<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marque<\/td>\n<td>Luleey<\/td>\n<\/tr>\n<tr>\n<td>Type de produit<\/td>\n<td>SC UPC Fixed Fiber Optic Attenuator<\/td>\n<\/tr>\n<tr>\n<td>Type de connecteur<\/td>\n<td>SC\/UPC<\/td>\n<\/tr>\n<tr>\n<td>Type d'att\u00e9nuateur<\/td>\n<td>Valeur fixe<\/td>\n<\/tr>\n<tr>\n<td>Type de fibre<\/td>\n<td>Fibre monomode<\/td>\n<\/tr>\n<tr>\n<td>Longueur d'onde de travail<\/td>\n<td>1310nm \/ 1550nm<\/td>\n<\/tr>\n<tr>\n<td>Valeurs d'att\u00e9nuation disponibles<\/td>\n<td>0 dB, 1 dB, 2 dB, 3 dB, 4 dB, 5 dB, 6 dB, 7 dB, 8 dB, 9 dB, 10 dB, 11 dB, 12 dB, 13 dB, 14 dB, 15 dB, 16 dB, 17 dB, 18 dB, 19 dB, 20 dB, 25 dB, 27 dB, 30 dB<\/td>\n<\/tr>\n<tr>\n<td>Plage d'att\u00e9nuation<\/td>\n<td>Valeurs fixes comprises entre 0 dB et 30 dB<\/td>\n<\/tr>\n<tr>\n<td>Perte de retour<\/td>\n<td>\u226550dB<\/td>\n<\/tr>\n<tr>\n<td>D\u00e9lais de r\u00e9utilisation<\/td>\n<td>Plus de 1 000 fois<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature de fonctionnement<\/td>\n<td>de -40 \u00b0C \u00e0 +85 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature de stockage<\/td>\n<td>-55\u00b0C to +85\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Mat\u00e9riau de base<\/td>\n<td>Ceramic<\/td>\n<\/tr>\n<tr>\n<td>Utilisation type<\/td>\n<td>R\u00e9duction de la puissance du signal optique et ajustement du budget de liaison<\/td>\n<\/tr>\n<tr>\n<td>Application r\u00e9seau<\/td>\n<td>FTTH, FTTX, CATV, PON, telecom, optical distribution, fiber testing<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Why Use an SC UPC Fiber Optic Attenuator?<\/h2>\n<p>A fiber optic attenuator is used when the optical signal power is too high for the receiving device. In fiber networks, too much optical power may overload the receiver and cause unstable links, device alarms, packet loss, or poor performance.<\/p>\n<p>A fixed attenuator helps:<\/p>\n<ul>\n<li>Reduce excessive optical power<\/li>\n<li>Protect optical receivers<\/li>\n<li>Balance optical link budgets<\/li>\n<li>Prevent receiver overload<\/li>\n<li>Improve link stability<\/li>\n<li>Support fiber testing and troubleshooting<\/li>\n<li>Simulate fiber loss in lab environments<\/li>\n<li>Match optical power requirements between different devices<\/li>\n<\/ul>\n<p>For FTTH, CATV, telecom, PON, and optical testing applications, the Luleey SC UPC Fixed Fiber Optic Attenuator is a practical passive component for optical power control.<\/p>\n<h2>SC APC vs SC UPC Attenuator<\/h2>\n<p>SC APC and SC UPC attenuators are not the same. They use different connector end-face structures and should not be mixed directly.<\/p>\n<table>\n<thead>\n<tr>\n<th>Type de connecteur<\/th>\n<th>Meilleur pour<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Att\u00e9nuateur SC APC<\/td>\n<td>FTTH, FTTX, CATV, PON, telecom, optical distribution, low-reflection single mode links<\/td>\n<\/tr>\n<tr>\n<td>SC UPC Attenuator<\/td>\n<td>General single mode optical links, test equipment, optical transceiver links, data communication systems<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Choose SC\/UPC when the connected fiber line, patch cable, adapter, ONU, OLT, splitter, or optical equipment also uses SC\/UPC.<\/p>\n<p>Choose SC\/APC only when the connected equipment and patch cable are SC\/UPC.<\/p>\n<p>Do not directly connect APC and UPC end-faces together, because this may cause poor contact, higher insertion loss, higher reflection, and unstable optical performance.<\/p>\n<h2>How to Choose the Right Attenuation Value<\/h2>\n<p>The correct attenuation value depends on the optical receiver input range and the actual received optical power. Before choosing the dB value, measure the current optical power with an optical power meter.<\/p>\n<table>\n<thead>\n<tr>\n<th>Valeur d'att\u00e9nuation<\/th>\n<th>Utilisation type<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0dB<\/td>\n<td>Connexion de r\u00e9f\u00e9rence, essais sp\u00e9cifiques, adaptation de connexion ou absence d'att\u00e9nuation intentionnelle<\/td>\n<\/tr>\n<tr>\n<td>de 1 dB \u00e0 3 dB<\/td>\n<td>L\u00e9g\u00e8re correction de la puissance optique<\/td>\n<\/tr>\n<tr>\n<td>de 4 dB \u00e0 7 dB<\/td>\n<td>R\u00e9duction mod\u00e9r\u00e9e de la puissance optique<\/td>\n<\/tr>\n<tr>\n<td>de 8 dB \u00e0 12 dB<\/td>\n<td>R\u00e9duction plus importante de la puissance optique pour les signaux re\u00e7us puissants<\/td>\n<\/tr>\n<tr>\n<td>de 13 dB \u00e0 20 dB<\/td>\n<td>Att\u00e9nuation importante pour les liaisons courtes, la r\u00e9gulation d'une puissance d'entr\u00e9e \u00e9lev\u00e9e ou la protection du r\u00e9cepteur<\/td>\n<\/tr>\n<tr>\n<td>25 dB \/ 27 dB \/ 30 dB<\/td>\n<td>Att\u00e9nuation tr\u00e8s importante pour les essais en laboratoire, les liaisons optiques \u00e0 haute puissance ou la simulation de budget de liaison<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The selected attenuator should reduce the received optical power into a safe and stable operating range.<\/p>","protected":false},"excerpt":{"rendered":"<p class=\"isSelectedEnd\">The Luleey SC UPC Fixed Fiber Optic Attenuator is designed to reduce optical signal power in single mode fiber networks with stable fixed attenuation values from 0dB to 30dB, helping protect optical receivers, balance link budgets, and optimize signal levels in FTTH, FTTX, CATV, telecom, data communication, and fiber testing applications.<\/p>\n<ul data-spread=\"false\">\n<li>SC\/UPC connector for low-reflection single mode fiber networks<\/li>\n<li>Valeurs fixes disponibles : 0 dB, 1 dB, 2 dB, 3 dB, 4 dB, 5 dB, 6 dB, 7 dB, 8 dB, 9 dB, 10 dB, 11 dB, 12 dB, 13 dB, 14 dB, 15 dB, 16 dB, 17 dB, 18 dB, 19 dB, 20 dB, 25 dB, 27 dB, 30 dB<\/li>\n<li>Contribue \u00e0 r\u00e9duire la puissance optique excessive et \u00e0 compenser les pertes sur la liaison par fibre optique<\/li>\n<li>UPC angled polish helps reduce back reflection in FTTH, CATV, PON, and telecom systems<\/li>\n<li>L'option 0 dB peut \u00eatre utilis\u00e9e pour une connexion de r\u00e9f\u00e9rence ou pour des applications de test sp\u00e9cifiques<\/li>\n<li>Les options 25 dB, 27 dB et 30 dB conviennent \u00e0 une r\u00e9duction importante de la puissance optique ou \u00e0 la simulation en laboratoire<\/li>\n<li>Convient aux \u00e9metteurs-r\u00e9cepteurs optiques, aux convertisseurs de m\u00e9dia, aux commutateurs, aux routeurs, aux serveurs, aux cartes r\u00e9seau fibre optique, aux p\u00e9riph\u00e9riques de stockage et aux \u00e9quipements de test optique<\/li>\n<\/ul>","protected":false},"featured_media":21453,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[788],"product_tag":[402,1291,1292,1293,1300,1301,1179],"class_list":["post-21451","product","type-product","status-publish","has-post-thumbnail","product_cat-optical-attenuator","product_tag-attenuator","product_tag-fiber-optic-attenuator","product_tag-fixed-attenuator","product_tag-optical-attenuator","product_tag-sc-upc-attenuator","product_tag-sc-upc-fixed-attenuator","product_tag-single-mode-fiber","first","instock","shipping-taxable","purchasable","product-type-variable","has-default-attributes"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/product\/21451","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/comments?post=21451"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/media\/21453"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/media?parent=21451"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/product_brand?post=21451"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/product_cat?post=21451"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/fr\/wp-json\/wp\/v2\/product_tag?post=21451"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}