{"id":21902,"date":"2026-08-22T14:40:44","date_gmt":"2026-08-22T06:40:44","guid":{"rendered":"https:\/\/www.luleey.com\/?p=21902"},"modified":"2026-08-22T14:40:47","modified_gmt":"2026-08-22T06:40:47","slug":"fiber-passes-a-vfl-test-but-still-has-no-link-why","status":"publish","type":"post","link":"https:\/\/www.luleey.com\/ja\/fiber-passes-a-vfl-test-but-still-has-no-link-why\/","title":{"rendered":"\u30d5\u30a1\u30a4\u30d0\u30fc\u306fVFL\u30c6\u30b9\u30c8\u306b\u5408\u683c\u3057\u305f\u3082\u306e\u306e\u3001\u4f9d\u7136\u3068\u3057\u3066\u63a5\u7d9a\u3055\u308c\u3066\u3044\u306a\u3044\u2015\u2015\u306a\u305c\uff1f"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-d71e5cf5\">\u3082\u3057\u3042\u306a\u305f\u306e <strong>fiber passes a <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/ja\/tag\/vfl-test\/\" title=\"View all posts in VFL Test\">VFL Test<\/a> but still has no link<\/strong>, the cable is not necessarily good enough for data transmission. Seeing red light at the far end mainly confirms that a continuous optical path exists. It does not prove that link loss, connector quality, wavelength, polarity, protocol, transceiver speed or received power is correct.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b21f9640\">A <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/ja\/tag\/visual-fault-locator\/\" title=\"Visual Fault Locator \u306e\u6295\u7a3f\u3092\u3059\u3079\u3066\u8868\u793a\">\u30d3\u30b8\u30e5\u30a2\u30eb\u30fb\u30d5\u30a9\u30eb\u30c8\u30fb\u30ed\u30b1\u30fc\u30bf\u30fc<\/a> is useful for finding a broken jumper, tracing a fiber, checking basic continuity and locating some sharp bends or cracked sections. It is not a complete fiber certification tool.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-c791c748\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-21903\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/vfl-pass-but-fiber-link-down-hero.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/vfl-pass-but-fiber-link-down-hero.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/vfl-pass-but-fiber-link-down-hero-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/vfl-pass-but-fiber-link-down-hero-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/vfl-pass-but-fiber-link-down-hero-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/vfl-pass-but-fiber-link-down-hero-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/vfl-pass-but-fiber-link-down-hero-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-8cf9cb5a\">What a Successful VFL Test Actually Proves<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a20b83f6\">A VFL injects visible red laser light\u2014commonly around 650nm\u2014into the fiber. If red light reaches the far end, the fiber can carry at least some light from one end to the other.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-217e1358\">A successful test can support these conclusions:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The fiber is probably not completely severed.<\/li>\n\n\n\n<li>The tested path likely reaches the expected far-end connector.<\/li>\n\n\n\n<li>A major break close enough to be visible may not be present.<\/li>\n\n\n\n<li>The fiber can be traced through a patch panel or bundle.<\/li>\n\n\n\n<li>Strong red-light leakage may help locate a crack, severe bend, bad mechanical connection or damaged splice.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7a7896ad\">The Fiber Optic Association describes a VFL as a tool for continuity, tracing and visually locating breaks or high-loss events. That is its strength.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b25cf2a0\">However, \u201csome visible light arrives\u201d is not the same as \u201cthe link meets its optical budget.\u201d<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-3d059176\">What a VFL Test Does Not Prove<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-0465a8aa\">It does not measure insertion loss<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-06346bb6\">Your eye cannot turn red-light brightness into a reliable dB measurement. A cable with excessive loss may still show visible red light at the far end, especially on a short jumper or when a high-output VFL is used.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9991b64d\">To measure loss, use a calibrated light source and <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/ja\/tag\/optical-power-meter\/\" title=\"\u5149\u30d1\u30ef\u30fc\u30e1\u30fc\u30bf\u30fc\u306e\u6295\u7a3f\u3092\u3059\u3079\u3066\u8868\u793a\">\u5149\u30d1\u30ef\u30fc\u30e1\u30fc\u30bf<\/a> with a valid reference. To check a live receiver input, measure optical power at the correct wavelength and compare it with the exact receiver specification.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-cbc7d004\">It does not verify the operating wavelength<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b11f8081\">A VFL uses visible red light, while communication systems normally use infrared wavelengths. A fiber path carrying 650nm light does not automatically prove correct performance at the system wavelength.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3df0464c\">It also cannot confirm that two transceivers use matching wavelengths. A BiDi pair with the wrong U\/D combination can pass a continuity test and still have no link.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-f318d66f\">It does not verify Tx\/Rx polarity<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b2e350d3\">A VFL can help trace individual fibers, but seeing red light through one strand does not prove that transmitter output reaches the correct receiver input in a duplex link.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9621d3fa\">For two-fiber Ethernet, TX on one side must reach RX on the other. Both fibers may be continuous while the link remains down because their positions are reversed.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-4ffa560f\">It does not verify protocol or speed<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3dceccde\">A continuous fiber cannot make incompatible equipment communicate. Examples include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>A 1G <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/ja\/tag\/sfp\/\" title=\"SFP \u306e\u6295\u7a3f\u3092\u3059\u3079\u3066\u8868\u793a\">\u306d\u3093\u308a\u3087\u3046\u30d7\u30fc\u30eb<\/a> paired with a host port fixed to an unsupported mode<\/li>\n\n\n\n<li>A 10G module paired with a 1G-only remote module<\/li>\n\n\n\n<li>An Ethernet transceiver connected to a PON interface<\/li>\n\n\n\n<li>A GPON ONU used on an incompatible XGS-PON service<\/li>\n\n\n\n<li>A module rejected because of coding, firmware, driver or host policy<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c977b5f3\">The physical SFP or SFP+ cage does not prove compatibility. Check the exact host SerDes mode, configured or negotiated rate, module encoding, firmware, driver and remote endpoint.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-2f260d9f\">It does not prove that receiver power is safe<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-571c6b9d\">The received signal may be too weak because of dirty connectors, splitter loss, bends, splices or distance. It may also be too strong and overload a sensitive receiver on a short link.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6fe4b43e\">A VFL cannot distinguish these conditions.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-5ff141ae\">It does not prove connector cleanliness<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-35e1593c\">A dirty connector can pass visible light while adding loss and reflection at the service wavelength. Reconnecting it may also transfer contamination to a clean adapter or transceiver port.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-1678f04f\">Seven Reasons the Link Is Still Down<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-b414711d\">1. Dirty or damaged connector end faces<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-efeb7ea5\">Dust, oil and scratches can increase insertion loss and reflection. Inspect and clean every accessible connection using appropriate procedures, then reconnect it without touching the ferrule.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-eebe540f\">Do not inspect an unknown fiber using a direct-view microscope until you have confirmed that no optical power is present.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-cf4d0e23\">2. Excessive loss that the VFL cannot quantify<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-209d682b\">A marginal connector, weak splice, long route, splitter or several smaller losses may leave enough visible red light for your eye while placing the actual receiver below its sensitivity limit.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-23421204\">Measure RX power in dBm or perform an insertion-loss test. Compare the result with the exact transceiver, ONU or ONT specification\u2014not a generic \u201cgood fiber power\u201d value.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-cd9ee188\">3. Duplex Tx\/Rx polarity is reversed<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-fa55c9b2\">This applies to two-fiber links. Label the existing positions, swap the two strands at one end only and check the link again. Restore the original arrangement if the link remains down.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-16a7970d\">Do not apply this method to single-fiber BiDi, PON, AOC or MPO connections. LuLeey\u2019s <a>fiber Tx\/Rx polarity guide<\/a> explains the correct scope and procedure.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-1522120c\">4. Wrong wavelength or BiDi pairing<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e199ec5d\">Two ordinary duplex transceivers normally use the same operating wavelength at both ends. Single-fiber BiDi modules instead require complementary transmit and receive wavelengths.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b576eca8\">Two modules with the same transmit wavelength normally cannot receive each other. Check the full model number and TX\/RX wavelength table rather than relying only on \u201c10G,\u201d \u201c20km\u201d or the connector type.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-997d54eb\">5. Fiber type does not match the optics<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a4ff1860\">Confirm single-mode versus multimode fiber, connector polish, core type and the transceiver specification. A connector may fit mechanically even when the optical system is mismatched.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-bc7eb7fa\">6. Module, port or host mode is incompatible<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0cadd283\">Check both endpoints:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Exact switch, router, NIC, media converter, ONU or ONT model<\/li>\n\n\n\n<li>Port speed and supported SerDes modes<\/li>\n\n\n\n<li>Auto-negotiation or forced-speed setting<\/li>\n\n\n\n<li>Module coding and vendor policy<\/li>\n\n\n\n<li>Firmware and driver version<\/li>\n\n\n\n<li>Module power and thermal limits<\/li>\n\n\n\n<li>Alarm, LOS and diagnostic logs<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b0810e6e\">Do not conclude that a module is compatible only because it fits the cage or because its name includes SFP, SFP+ or a nominal data rate.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-0d4606a8\">7. The optical path works, but service is not provisioned<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c7968822\">This is common in PON networks. An ONU may receive downstream light but still fail to register because of an incorrect serial number, LOID, password, OMCI profile, VLAN, service profile, OLT authorization or unsupported ONU\/OLT combination.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ffbf4576\">VFL continuity cannot test registration or service configuration.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d1e8faf2\"><\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-f37956b7\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-21904\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/vfl-fiber-troubleshooting-workflow.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/vfl-fiber-troubleshooting-workflow.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/vfl-fiber-troubleshooting-workflow-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/vfl-fiber-troubleshooting-workflow-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/vfl-fiber-troubleshooting-workflow-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/vfl-fiber-troubleshooting-workflow-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/vfl-fiber-troubleshooting-workflow-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-69f72c6e\">A Better Troubleshooting Order<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-9b2039a9\">Step 1: Make the fiber safe to work on<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8f274fdc\">Follow the network operator and equipment procedures. Disconnect active equipment where required. Use a power meter to check for optical power before handling or inspecting an unknown fiber.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-45114d4c\">Never look into a fiber connector, transceiver, adapter or VFL output. View VFL leakage from the side, not along the fiber axis.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-487ed92a\">Step 2: Inspect and clean<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-fd19614f\">Inspect accessible end faces after confirming that the fiber is safe. Clean, reinspect and replace visibly damaged jumpers.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-7c253bed\">Step 3: Use the VFL for continuity and local faults<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-20cc277f\">Connect the correct adapter, select continuous or pulsed mode as needed and trace the fiber. Look from the side for leakage at bends, connectors, splices or damaged sections.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4a717ce7\">Use only the output level appropriate for the task and follow the device\u2019s laser classification and safety instructions. A larger advertised mW value is not proof of a better or more accurate test.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ec42bf7c\">LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/ja\/product\/visual-fault-locator-1mw-10mw-20mw-30mw-50mw-vfl-laser-pen-ll-vfl-noli\/\">650nm visual fault locator<\/a> supports continuous and pulsed operation for tracing and visible fault location. Select the version and connector adapter for the actual environment rather than choosing only by claimed distance.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-59ef2c21\">Step 4: Verify topology and polarity<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-da4f0e90\">Confirm that you tested the intended fiber. For duplex links, trace both strands and verify TX-to-RX routing. For BiDi and PON, confirm that the link is supposed to use one fiber.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-323ad7ef\">Step 5: Measure optical power or loss<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-81ca8e03\">Use an optical power meter supporting the operating wavelength and expected power range. Select the correct wavelength setting.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-500c2e8c\">For formal insertion-loss testing, use a compatible test source, reference cables and a properly established reference. A power-meter reading taken at the wrong wavelength or without the correct reference can be misleading.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9b8906d3\">LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/ja\/product-category\/testers-and-tools\/optical-power-meter-and-visual-fault-locator\/\">optical power meter category<\/a> includes general power meters and PON-oriented testers. Choose according to wavelength, measurement range, connector and whether the task involves a disconnected fiber or an in-service PON measurement.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-562641f0\">Step 6: Compare against the exact equipment specifications<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2d975e43\">Record TX power, RX power, receiver sensitivity, overload limit, wavelength, rate, distance class, fiber type and connector polish for both endpoints.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8c41df2b\">DDM\/DOM readings can help, but they have implementation and accuracy limits. If a result is close to a threshold, confirm it with suitable calibrated test equipment.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-280825ae\">Step 7: Check equipment and service configuration<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5d6f6416\">Review port state, speed, firmware, driver, module alarms and error counters. For PON, check registration and OLT provisioning after confirming that optical power is acceptable.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-74ea8c1b\">When to Use an OTDR<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-63f0bd95\">Use an OTDR when you need to locate an event along a longer or inaccessible route, such as a break, reflective connector, poor splice or unexpected loss point.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a4358ae9\">An OTDR requires the correct wavelength, pulse width, range, refractive-index setting, launch cable and often a receive cable. Its trace should be interpreted by someone who understands dead zones, event loss, reflectance and backscatter.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d13b773e\">An OTDR is not a replacement for an end-to-end insertion-loss test. The Fiber Optic Association notes that source-and-power-meter testing measures cable-plant loss directly, while an OTDR makes an indirect measurement from backscatter.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-90782fc2\">\u6700\u7d42\u7684\u306a\u7b54\u3048<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4634680c\">If red VFL light reaches the far end but the fiber link remains down, the VFL has answered only one question:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-914c4e42\"><strong>The path carries some visible light.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ff9396a4\">Next, check cleanliness, measured optical power or loss, duplex polarity, wavelength pairing, fiber type, module compatibility, host port mode and service provisioning.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6d88dae0\">Use the tools in this order:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Inspection and cleaning<\/li>\n\n\n\n<li>VFL for continuity and visible local faults<\/li>\n\n\n\n<li>Optical power meter or OLTS for power and loss<\/li>\n\n\n\n<li>DDM, logs and device specifications for compatibility<\/li>\n\n\n\n<li>OTDR when the event location remains unknown<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ac57f39b\">Before selecting a tester, provide LuLeey with the network type, wavelength, connector, expected power range, route length and whether the fiber must remain in service. Those details determine whether the job needs a VFL, standard power meter, wavelength-selective PON meter or OTDR.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":21903,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1077],"tags":[57,1419,1391,1436,69,1435,407],"class_list":["post-21902","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-problem-cases","tag-optical-power-meter","tag-fiber-link-down","tag-fiber-troubleshooting","tag-ftth-maintenance","tag-sfp","tag-vfl-test","tag-visual-fault-locator"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/ja\/wp-json\/wp\/v2\/posts\/21902","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luleey.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/ja\/wp-json\/wp\/v2\/comments?post=21902"}],"version-history":[{"count":1,"href":"https:\/\/www.luleey.com\/ja\/wp-json\/wp\/v2\/posts\/21902\/revisions"}],"predecessor-version":[{"id":21905,"href":"https:\/\/www.luleey.com\/ja\/wp-json\/wp\/v2\/posts\/21902\/revisions\/21905"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/ja\/wp-json\/wp\/v2\/media\/21903"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/ja\/wp-json\/wp\/v2\/media?parent=21902"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luleey.com\/ja\/wp-json\/wp\/v2\/categories?post=21902"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/ja\/wp-json\/wp\/v2\/tags?post=21902"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}