{"id":21825,"date":"2026-08-18T12:06:38","date_gmt":"2026-08-18T04:06:38","guid":{"rendered":"https:\/\/www.luleey.com\/?p=21825"},"modified":"2026-08-19T23:38:57","modified_gmt":"2026-08-19T15:38:57","slug":"fiber-link-down-how-to-check-tx-rx-polarity","status":"publish","type":"post","link":"https:\/\/www.luleey.com\/pt\/fiber-link-down-how-to-check-tx-rx-polarity\/","title":{"rendered":"A conex\u00e3o de fibra est\u00e1 fora de servi\u00e7o? Como verificar a polaridade de transmiss\u00e3o (Tx) e recep\u00e7\u00e3o (Rx) da fibra"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-bac767c7\">Seus m\u00f3dulos SFP foram detectados e o cabo de fibra est\u00e1 conectado, mas a luz de link permanece apagada. Antes de substituir os transceptores ou o cabo de conex\u00e3o, verifique o <strong>fibra <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/tx-rx\/\" title=\"Ver todas as publica\u00e7\u00f5es no Tx Rx\">Tx Rx<\/a> polaridade<\/strong>.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-b4cdab7b\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"630\" class=\"wp-image-21831\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/fiber-tx-rx-polarity-hero.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/fiber-tx-rx-polarity-hero.png 1200w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/fiber-tx-rx-polarity-hero-800x420.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/fiber-tx-rx-polarity-hero-768x403.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/fiber-tx-rx-polarity-hero-18x9.png 18w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/fiber-tx-rx-polarity-hero-150x79.png 150w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/div>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-cc9f488f\"><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-bde59305\">Em uma conex\u00e3o normal de duas fibras:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>O transmissor local (Tx) deve se conectar ao receptor remoto (Rx)<\/li>\n\n\n\n<li>O Rx local deve se conectar ao Tx remoto<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-695ea3fb\">Se o Tx for conectado ao Tx e o Rx for conectado ao Rx, normalmente n\u00e3o \u00e9 poss\u00edvel estabelecer o link.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-64dd07e3\">A boa not\u00edcia \u00e9 que, geralmente, leva apenas alguns minutos para verificar esse problema.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-69eed6ec\">Resposta r\u00e1pida<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d0026c02\">Se voc\u00ea estiver usando um <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/duplex-lc\/\" title=\"Ver todas as publica\u00e7\u00f5es na categoria Duplex LC\">LC duplex<\/a> ou para conex\u00e3o SC duplex, troque os dois fios de fibra em <strong>apenas em uma das extremidades<\/strong>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Se a conex\u00e3o for estabelecida, a polaridade original foi invertida.<\/li>\n\n\n\n<li>Se o link continuar inativo, restabele\u00e7a a conex\u00e3o original e continue verificando os m\u00f3dulos, o tipo de fibra, o comprimento de onda e a pot\u00eancia \u00f3ptica.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-62262e0c\">N\u00e3o utilize este m\u00e9todo em conex\u00f5es BiDi de fibra \u00fanica, PON, AOC ou MPO.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-fc3258c6\">Esse teste se aplica ao seu link de fibra \u00f3ptica?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-dfa2144d\">Utilize o teste de troca de fios somente quando sua conex\u00e3o apresentar:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>dois fios de fibra separados;<\/li>\n\n\n\n<li>uma interface \u00f3ptica duplex, geralmente do tipo LC duplex;<\/li>\n\n\n\n<li>um fio para transmiss\u00e3o;<\/li>\n\n\n\n<li>um fio para recep\u00e7\u00e3o.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-aae582cd\">Um exemplo t\u00edpico \u00e9 uma conex\u00e3o entre switches que utiliza dois transceptores SFP ou SFP+ duplex padr\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4aceb924\">N\u00e3o troque os fios nas seguintes situa\u00e7\u00f5es:<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-b2118262\">Transceptores BiDi de fibra \u00fanica<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9a678b7e\">Um transceptor BiDi transmite e recebe pela mesma fibra utilizando dois comprimentos de onda diferentes. N\u00e3o h\u00e1 fios separados de transmiss\u00e3o (Tx) e recep\u00e7\u00e3o (Rx) para trocar.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0b917fe3\">Em vez disso, verifique se os dois m\u00f3dulos BiDi utilizam comprimentos de onda de transmiss\u00e3o (Tx) e recep\u00e7\u00e3o (Rx) complementares.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-34c3e326\">Por exemplo, um m\u00f3dulo que transmite a 1270 nm deve, normalmente, ser conectado a um m\u00f3dulo que recebe a 1270 nm e transmite no comprimento de onda de retorno correspondente.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ee96bfd5\">Consulte o guia do LuLeey: <a href=\"https:\/\/www.luleey.com\/pt\/sfp-10g-bx10-d-vs-sfp-10g-bx10-u-what-is-the-difference\/\">SFP-10G-BX10-D x SFP-10G-BX10-U<\/a>.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-619e152a\">GPON, EPON e XGS-PON<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-eba03f48\">As conex\u00f5es PON normalmente utilizam uma \u00fanica fibra tanto para a comunica\u00e7\u00e3o de downstream quanto para a de upstream. O teste duplex de troca de fios n\u00e3o se aplica.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-24295972\">Cabos AOC<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7c114fea\">As fibras \u00f3pticas e os transceptores de um cabo \u00f3ptico ativo s\u00e3o terminados na f\u00e1brica como um conjunto completo. O usu\u00e1rio n\u00e3o pode inverter os percursos internos das fibras.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-a091f18c\">Conex\u00f5es MPO\/MTP<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5c66fb94\">Os sistemas MPO\/MTP utilizam m\u00faltiplas fibras e m\u00e9todos espec\u00edficos de polaridade. N\u00e3o inverta aleatoriamente fibras individuais. Verifique se o link requer o M\u00e9todo A, o M\u00e9todo B, o M\u00e9todo C ou uma configura\u00e7\u00e3o de breakout compat\u00edvel.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-9eee6eea\">Como verificar a polaridade de transmiss\u00e3o e recep\u00e7\u00e3o da fibra \u00f3ptica<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-d10b746e\">Passo 1: Confirme se se trata de um link de duas fibras<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-fb420ba6\">Observe a conex\u00e3o \u00f3ptica.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a26dce53\">Uma conex\u00e3o LC duplex geralmente \u00e9 composta por dois pequenos conectores LC unidos entre si. Uma fibra transmite o sinal em uma dire\u00e7\u00e3o, enquanto a outra fibra transmite o sinal de retorno.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f42b0747\">Se a conex\u00e3o utilizar apenas uma fibra, pare por aqui. Pode ser um link BiDi ou PON, e este teste n\u00e3o se aplica.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-420f5ba8\">Etapa 2: Registrar a conex\u00e3o atual<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ed714dfe\">Tire uma foto ou identifique os dois fios de fibra antes de fazer qualquer altera\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-93fe5d3b\">Isso facilita a restaura\u00e7\u00e3o da conex\u00e3o original caso a polaridade n\u00e3o seja a causa do problema.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c0599d27\">N\u00e3o olhe diretamente para uma porta \u00f3ptica ou um conector de fibra \u00f3ptica. Os sinais \u00f3pticos podem ser invis\u00edveis ao olho humano. Siga as <a href=\"https:\/\/www.thefoa.org\/tech\/ref\/safety\/safe.html\" target=\"_blank\" rel=\"noopener\">Orienta\u00e7\u00f5es de seguran\u00e7a para fibras \u00f3pticas da Associa\u00e7\u00e3o de Fibra \u00d3ptica<\/a>.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-3aaf41b9\">Passo 3: Troque as duas mechas em uma das extremidades<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0881defb\">Escolha uma das extremidades do cabo e inverta as posi\u00e7\u00f5es das duas fibras:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Desconecte os dois conectores de fibra com cuidado.<\/li>\n\n\n\n<li>Mova a primeira mecha para a posi\u00e7\u00e3o anteriormente ocupada pela segunda mecha.<\/li>\n\n\n\n<li>Mova a segunda mecha para a primeira posi\u00e7\u00e3o.<\/li>\n\n\n\n<li>Reconecte ambas as fibras completamente.<\/li>\n\n\n\n<li>Deixe a extremidade oposta como est\u00e1.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f6bfea2c\">Troque os fios apenas em uma das extremidades. Trocar as duas extremidades geralmente restabelece a polaridade original.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a0a14405\">Se os conectores LC estiverem travados dentro de um clipe duplex fixo, n\u00e3o force o clipe para abri-lo. Utilize um mecanismo de invers\u00e3o de polaridade compat\u00edvel, inverta o par no painel de conex\u00f5es ou utilize um cabo de conex\u00e3o duplex com polaridade revers\u00edvel.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-45eefcba\">Etapa 4: Verifique o indicador de conex\u00e3o<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4349534f\">Aguarde at\u00e9 que o switch, o roteador ou a placa de rede concluam a inicializa\u00e7\u00e3o normal da conex\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f8938d4d\">Em seguida, verifique o status da porta.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Resultado do teste<\/th><th>O que isso significa<\/th><\/tr><\/thead><tbody><tr><td>O link aparece<\/td><td>A polaridade original de Tx\/Rx foi invertida<\/td><\/tr><tr><td>O link continua indispon\u00edvel<\/td><td>A polaridade pode n\u00e3o ser o principal problema<\/td><\/tr><tr><td>O link fica ficando online e offline repetidamente<\/td><td>Verifique a limpeza do conector, a pot\u00eancia \u00f3ptica e as configura\u00e7\u00f5es da porta<\/td><\/tr><tr><td>Apenas um lado recebe pot\u00eancia \u00f3ptica<\/td><td>Verifique o fio de retorno, o conector e o transmissor remoto<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8f934366\">O <a href=\"https:\/\/www.thefoa.org\/tech\/ref\/install\/polarity.html\" target=\"_blank\" rel=\"noopener\">Guia de polaridade do conector FOA<\/a> explica por que os links de fibra \u00f3ptica devem manter o caminho correto entre a transmiss\u00e3o e a recep\u00e7\u00e3o. O p\u00fablico <a href=\"https:\/\/datatracker.ietf.org\/doc\/html\/rfc5171\" target=\"_blank\" rel=\"noopener\">IETF RFC 5171<\/a> tamb\u00e9m descreve como uma conex\u00e3o incorreta de fibra \u00f3ptica pode criar um caminho de comunica\u00e7\u00e3o inv\u00e1lido ou unidirecional.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a82ed790\"><\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-f941bb37\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"800\" class=\"wp-image-21833\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/content_idfile_00000000c3548246ba71fd9e71afc4d1ts496407pfscid1sig8a5fdf0e23eb93af1d9ea92c99785a15db3ef4badce37e0671c86b4b4a5abde7v0.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/content_idfile_00000000c3548246ba71fd9e71afc4d1ts496407pfscid1sig8a5fdf0e23eb93af1d9ea92c99785a15db3ef4badce37e0671c86b4b4a5abde7v0.png 1200w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/content_idfile_00000000c3548246ba71fd9e71afc4d1ts496407pfscid1sig8a5fdf0e23eb93af1d9ea92c99785a15db3ef4badce37e0671c86b4b4a5abde7v0-800x533.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/content_idfile_00000000c3548246ba71fd9e71afc4d1ts496407pfscid1sig8a5fdf0e23eb93af1d9ea92c99785a15db3ef4badce37e0671c86b4b4a5abde7v0-768x512.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/content_idfile_00000000c3548246ba71fd9e71afc4d1ts496407pfscid1sig8a5fdf0e23eb93af1d9ea92c99785a15db3ef4badce37e0671c86b4b4a5abde7v0-18x12.png 18w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/content_idfile_00000000c3548246ba71fd9e71afc4d1ts496407pfscid1sig8a5fdf0e23eb93af1d9ea92c99785a15db3ef4badce37e0671c86b4b4a5abde7v0-150x100.png 150w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-5e0c582b\">O que voc\u00ea deve fazer se o link aparecer?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6f87768f\">Se o link funcionar depois de trocar os dois fios de lugar:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Mantenha a polaridade de funcionamento.<\/li>\n\n\n\n<li>Identifique ambas as cadeias.<\/li>\n\n\n\n<li>Registre a conex\u00e3o em ambas as extremidades.<\/li>\n\n\n\n<li>Prenda o cabo sem fazer curvas muito fechadas.<\/li>\n\n\n\n<li>Verifique se a velocidade da conex\u00e3o est\u00e1 correta.<\/li>\n\n\n\n<li>Verifique se h\u00e1 erros de pacotes ou funcionamento inst\u00e1vel.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-069fb2b4\">N\u00e3o \u00e9 necessariamente preciso trocar o cabo. No entanto, utilize um cabo de conex\u00e3o devidamente fioado ou com polaridade revers\u00edvel se a conex\u00e3o atual exigir for\u00e7ar, desmontar ou deixar os conectores soltos.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-c0ed20e7\">E se a troca de Tx\/Rx n\u00e3o resolver o problema do link?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-fa00746f\">Restabele\u00e7a a conex\u00e3o original e verifique os itens a seguir, nessa ordem.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-1512a2d1\">1. As duas portas est\u00e3o ativadas?<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0d403619\">Verifique se nenhuma das portas \u00f3pticas foi desativada nas configura\u00e7\u00f5es do switch, do roteador ou da placa de rede.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-c357fdf9\">2. Ambos os lados utilizam a mesma taxa de transmiss\u00e3o de dados?<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7fe06108\">Um transceptor de 1G e um transceptor de 10G normalmente n\u00e3o conseguem estabelecer um link Ethernet padr\u00e3o entre si.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0cd9f7c9\">Verifique tamb\u00e9m se a porta do host suporta a velocidade necess\u00e1ria. As siglas SFP, SFP+ ou SFP28, por si s\u00f3, n\u00e3o garantem todas as velocidades intermedi\u00e1rias.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-d2199fe0\">3. Os transceptores utilizam padr\u00f5es \u00f3pticos compat\u00edveis?<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b342a136\">Ambos os lados devem utilizar:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>taxas de transmiss\u00e3o de dados;<\/li>\n\n\n\n<li>comprimentos de onda;<\/li>\n\n\n\n<li>dist\u00e2ncias de transmiss\u00e3o;<\/li>\n\n\n\n<li>tipos de fibra;<\/li>\n\n\n\n<li>padr\u00f5es \u00f3pticos.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-880ccd7a\">N\u00e3o presuma que dois m\u00f3dulos sejam compat\u00edveis simplesmente porque ambos possuem conectores LC.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-6a520ded\">4. O tipo de fibra est\u00e1 correto?<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-82907b9e\">Utilize fibra monomodo com transceptores monomodo.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c5adfa1b\">Utilize a fibra multimodo correta com transceptores multimodo. As fibras OM1, OM2, OM3, OM4 e OM5 n\u00e3o oferecem o mesmo desempenho de transmiss\u00e3o em todas as velocidades e dist\u00e2ncias.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-1ddeb8fb\">5. Os conectores est\u00e3o limpos?<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-914e94aa\">A poeira e a contamina\u00e7\u00e3o podem aumentar a perda de inser\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b2ddfc01\">N\u00e3o toque na face do conector. Caso seja necess\u00e1rio limp\u00e1-lo, utilize ferramentas adequadas para limpeza de fibra \u00f3ptica, em vez de len\u00e7os de papel comuns, tecidos ou ar comprimido de qualidade desconhecida.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-9cb96f57\">6. O cabo est\u00e1 muito dobrado ou danificado?<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-18815156\">Verifique se o cabo est\u00e1:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>presos debaixo de m\u00f3veis;<\/li>\n\n\n\n<li>fez uma curva fechada;<\/li>\n\n\n\n<li>apertado demais;<\/li>\n\n\n\n<li>apertado por uma bra\u00e7adeira de cabo;<\/li>\n\n\n\n<li>danificado pr\u00f3ximo ao conector.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-fb336892\">Mantenha a fibra em curvas suaves e relaxadas.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-64242f3b\">7. A pot\u00eancia \u00f3ptica recebida est\u00e1 dentro da faixa?<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2cd1ae69\">Se o dispositivo for compat\u00edvel com DDM ou DOM, verifique a pot\u00eancia \u00f3ptica de transmiss\u00e3o (Tx) e recep\u00e7\u00e3o (Rx) informada.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-03ece1c8\">Compare a pot\u00eancia recebida com o alcance do receptor especificado para o transceptor. Uma pot\u00eancia \u00f3ptica muito baixa pode impedir o estabelecimento do link, enquanto uma pot\u00eancia excessiva pode sobrecarregar o receptor em algumas conex\u00f5es curtas de modo \u00fanico.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-06cf70e9\">O <a href=\"https:\/\/www.thefoa.org\/tech\/ref\/testing\/test\/network-troubleshooting.html\" target=\"_blank\" rel=\"noopener\">Guia de solu\u00e7\u00e3o de problemas da rede de fibra FOA<\/a> recomenda verificar a pot\u00eancia do receptor, a pot\u00eancia do transmissor, os transceptores e a perda de link ao diagnosticar problemas em redes \u00f3pticas.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4bfca49c\">Caso as informa\u00e7\u00f5es do DDM n\u00e3o estejam dispon\u00edveis, utilize um medidor de pot\u00eancia \u00f3ptica e o procedimento de teste correto. O <a href=\"https:\/\/www.thefoa.org\/tech\/ref\/basic\/test.html\" target=\"_blank\" rel=\"noopener\">Guia de testes de fibra \u00f3ptica da FOA<\/a> explica a rela\u00e7\u00e3o b\u00e1sica entre a pot\u00eancia do transmissor, a pot\u00eancia do receptor e a perda no link.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-08f9d237\">Um exemplo simples<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b6a63954\">Dois switches est\u00e3o conectados por meio de transceptores SFP+ LC duplex.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3dc606da\">Ambos os switches detectam seus transceptores, mas os indicadores de conex\u00e3o permanecem apagados.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6a2fbfff\">Atualmente, o trajeto do cabo conecta:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Transmiss\u00e3o do Switch A \u2192 Transmiss\u00e3o do Switch B<\/li>\n\n\n\n<li>Switch A Rx \u2190 Switch B Rx<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d4f831d2\">Nenhum dos receptores est\u00e1 conectado ao transmissor oposto.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0f33d61a\">Depois de trocar os dois fios apenas no comutador B, o caminho passa a ser:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Switch A Tx \u2192 Switch B Rx<\/li>\n\n\n\n<li>Switch A (Rx) \u2190 Switch B (Tx)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-fcd8b1b3\">Agora \u00e9 poss\u00edvel estabelecer a conex\u00e3o, desde que os transceptores, a velocidade, o comprimento de onda, o tipo de fibra e a pot\u00eancia \u00f3ptica tamb\u00e9m sejam compat\u00edveis.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-2dce2700\">Lista de verifica\u00e7\u00e3o final<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7ac2123c\">Quando um novo link de fibra duplex fica fora de servi\u00e7o:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Confirme se trata-se de um link duplex de duas fibras.<\/li>\n\n\n\n<li>Tire uma foto da conex\u00e3o original.<\/li>\n\n\n\n<li>Nunca olhe diretamente para uma porta \u00f3ptica.<\/li>\n\n\n\n<li>Troque as duas mechas apenas em uma das extremidades.<\/li>\n\n\n\n<li>Verifique se o link funciona.<\/li>\n\n\n\n<li>Se continuar fora do ar, restabele\u00e7a a conex\u00e3o original.<\/li>\n\n\n\n<li>Verifique o status da porta, a taxa do m\u00f3dulo, o comprimento de onda e o tipo de fibra.<\/li>\n\n\n\n<li>Limpe os conectores e recoloque-os corretamente.<\/li>\n\n\n\n<li>Verifique se o cabo apresenta dobras acentuadas ou danos.<\/li>\n\n\n\n<li>Me\u00e7a ou verifique a pot\u00eancia \u00f3ptica recebida.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-06241b08\">Antes de escolher novos transceptores ou cabos de conex\u00e3o, leia o <a href=\"https:\/\/www.luleey.com\/pt\/lc-vs-sc-vs-mpo-how-to-choose-the-right-fiber-connector-for-1g-to-100g-networks\/\">Guia de conectores LC, SC e MPO<\/a> ou d\u00ea uma olhada no LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/pt\/categoria-produto\/optical_module_transceivers\/\">transceptores de m\u00f3dulos \u00f3pticos<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Resultado do teste O que isso significa A conex\u00e3o \u00e9 restabelecida A polaridade original de Tx\/Rx estava invertida A conex\u00e3o permanece interrompida A polaridade pode n\u00e3o estar<\/p>","protected":false},"author":1,"featured_media":21831,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1077],"tags":[1416,1417,1419,1420,1418],"class_list":["post-21825","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-problem-cases","tag-tx-rx","tag-duplex-lc","tag-fiber-link-down","tag-fiber-polarity","tag-sfp-troubleshooting"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts\/21825","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/comments?post=21825"}],"version-history":[{"count":0,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts\/21825\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/media\/21831"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/media?parent=21825"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/categories?post=21825"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/tags?post=21825"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}