{"id":21921,"date":"2026-08-23T11:15:49","date_gmt":"2026-08-23T03:15:49","guid":{"rendered":"https:\/\/www.luleey.com\/?p=21921"},"modified":"2026-08-23T11:15:52","modified_gmt":"2026-08-23T03:15:52","slug":"fiber-optic-splitter-loss-12-to-164-guide","status":"publish","type":"post","link":"https:\/\/www.luleey.com\/pt\/fiber-optic-splitter-loss-12-to-164-guide\/","title":{"rendered":"Guia sobre perda em divisores de fibra \u00f3ptica: de 1:2 a 1:64"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-e09aa1e4\"><strong><a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/fiber-optic-splitter-loss\/\" title=\"Ver todas as publica\u00e7\u00f5es sobre perda em divisores de fibra \u00f3ptica\">Perda no divisor de fibra \u00f3ptica<\/a><\/strong> n\u00e3o \u00e9 o n\u00famero impresso ap\u00f3s \u201c1:\u201d. Um divisor 1:8 n\u00e3o apresenta uma perda ideal de 8 dB. Como a pot\u00eancia de entrada \u00e9 dividida igualmente entre oito sa\u00eddas, sua perda ideal \u00e9 de cerca de 9,03 dB por sa\u00edda. Um divisor real apresenta perdas adicionais; portanto, sua perda de inser\u00e7\u00e3o m\u00e1xima especificada ser\u00e1 maior.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-785b7d6c\">Este guia apresenta a perda ideal na faixa de 1:2 a 1:64, explica por que os valores reais s\u00e3o maiores e fornece um m\u00e9todo pr\u00e1tico para incluir a perda do divisor no or\u00e7amento de link de uma rede FTTH ou PON.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-c868a014\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-21922\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/fiber-optic-splitter-loss-hero.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/fiber-optic-splitter-loss-hero.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/fiber-optic-splitter-loss-hero-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/fiber-optic-splitter-loss-hero-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/fiber-optic-splitter-loss-hero-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/fiber-optic-splitter-loss-hero-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/fiber-optic-splitter-loss-hero-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-1c17f760\">F\u00f3rmula para o c\u00e1lculo da perda em divisores de fibra \u00f3ptica<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c0e12abc\">Em um divisor 1:N balanceado, idealmente cada sa\u00edda recebe <code>1\/N<\/code> da pot\u00eancia \u00f3ptica de entrada.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f154a5a8\">A magnitude ideal de atenua\u00e7\u00e3o \u00e9:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-fe7838e0\"><strong>Perda ideal do divisor (dB) = 10 \u00d7 log10(N)<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-cb5a6623\">Por exemplo, um divisor de 1:8 possui oito sa\u00eddas iguais:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-130b5335\"><strong>10 \u00d7 log10(8) = 9,03 dB<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7ed46859\">Se a pot\u00eancia \u00f3ptica que entra em um divisor ideal de 1:8 for de 0 dBm, cada sa\u00edda teria aproximadamente \u22129,03 dBm, sem levar em conta perdas adicionais, conectores ou toler\u00e2ncias de fabrica\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e96786a5\">Na nota\u00e7\u00e3o de raz\u00e3o de pot\u00eancias, a varia\u00e7\u00e3o \u00e9 <code>10 \u00d7 log10(1\/N)<\/code>, o que \u00e9 negativo. Em um balan\u00e7o de link, a atenua\u00e7\u00e3o \u00e9 normalmente expressa como um valor positivo de perda e subtra\u00edda da pot\u00eancia do transmissor.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-f82ce2e6\">Tabela de perdas do divisor de fibra \u00f3ptica: 1:2 a 1:64<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u00cdndice de divis\u00e3o<\/th><th>Pot\u00eancia ideal por sa\u00edda<\/th><th>Perda ideal exata<\/th><th>Perda ideal arredondada<\/th><th>Exemplo de perda de inser\u00e7\u00e3o t\u00edpica do FOA*<\/th><\/tr><\/thead><tbody><tr><td>1:2<\/td><td>50%<\/td><td>3,01 dB<\/td><td>3 dB<\/td><td>3,6 dB<\/td><\/tr><tr><td>1:4<\/td><td>25%<\/td><td>6,02 dB<\/td><td>6 dB<\/td><td>6,8 dB<\/td><\/tr><tr><td>1:8<\/td><td>12.5%<\/td><td>9,03 dB<\/td><td>9 dB<\/td><td>10,0 dB<\/td><\/tr><tr><td>1:16<\/td><td>6.25%<\/td><td>12,04 dB<\/td><td>12 dB<\/td><td>13,0 dB<\/td><\/tr><tr><td>1:32<\/td><td>3.125%<\/td><td>15,05 dB<\/td><td>15 dB<\/td><td>16,0 dB<\/td><\/tr><tr><td>1:64<\/td><td>1.5625%<\/td><td>18,06 dB<\/td><td>18 dB<\/td><td>19,5 dB<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4c56107d\">*A coluna sobre perda de inser\u00e7\u00e3o t\u00edpica \u00e9 um exemplo ilustrativo publicado pela <a href=\"https:\/\/www.thefoa.org\/tech\/ref\/install\/Optical_splitter.html?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Associa\u00e7\u00e3o de Fibra \u00d3ptica<\/a>. N\u00e3o se trata de uma especifica\u00e7\u00e3o universal. Utilize o valor m\u00e1ximo de perda de inser\u00e7\u00e3o indicado na ficha t\u00e9cnica do divisor espec\u00edfico que est\u00e1 sendo instalado.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4a98389b\">Uma regra pr\u00e1tica \u00fatil \u00e9 que cada duplica\u00e7\u00e3o da contagem de sa\u00edda acrescenta aproximadamente 3,01 dB de perda ideal:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>1:8 a 1:16: cerca de 3,01 dB a mais<\/li>\n\n\n\n<li>1:16 a 1:32: cerca de 3,01 dB a mais<\/li>\n\n\n\n<li>1:32 a 1:64: cerca de 3,01 dB a mais<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c1bd5fe1\">\u00c9 por isso que aumentar a capacidade de produ\u00e7\u00e3o excedente n\u00e3o \u00e9, aparentemente, gratuito.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-631e740b\">Por que a perda real do divisor \u00e9 maior do que a calculada pela f\u00f3rmula<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-16933370\">A f\u00f3rmula descreve a divis\u00e3o perfeita de pot\u00eancia. Um divisor fabricado tamb\u00e9m apresenta perdas nos componentes e toler\u00e2ncias de fabrica\u00e7\u00e3o.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-c7ea0c12\">Perda excedente<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c7c8e2a8\">Parte da pot\u00eancia \u00f3ptica \u00e9 perdida no interior do componente, em vez de chegar \u00e0 sa\u00edda. A diferen\u00e7a entre a perda de divis\u00e3o ideal e a perda de inser\u00e7\u00e3o medida inclui essa inefici\u00eancia e outros efeitos relacionados \u00e0 constru\u00e7\u00e3o.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-fdefc7b1\">Uniformidade entre portas<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a5ee3d80\">As portas de sa\u00edda n\u00e3o s\u00e3o perfeitamente id\u00eanticas. A uniformidade de perda descreve a diferen\u00e7a entre a porta de sa\u00edda mais forte e a mais fraca. A porta mais fraca permitida \u00e9 importante ao verificar o or\u00e7amento de link no pior caso.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-815ac9ab\">Constru\u00e7\u00e3o com conectores ou com fibra nua<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-378deca0\">Um divisor com conectores pode incluir a perda relacionada aos conectores em seu valor de perda de inser\u00e7\u00e3o publicado, mas os m\u00e9todos de especifica\u00e7\u00e3o podem variar. Verifique se o valor indicado na ficha t\u00e9cnica se aplica ao conjunto completo com termina\u00e7\u00e3o ou apenas ao componente divisor.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-271d0b79\">Comprimento de onda, temperatura e toler\u00e2ncia<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-cc63fd9a\">A perda de inser\u00e7\u00e3o pode variar de acordo com o comprimento de onda de opera\u00e7\u00e3o, a temperatura e a toler\u00e2ncia de fabrica\u00e7\u00e3o. Utilize a especifica\u00e7\u00e3o garantida em todos os comprimentos de onda e na faixa ambiental exigidos pela rede.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e340ec5e\">A norma ITU-T G.671 define par\u00e2metros de transmiss\u00e3o para componentes \u00f3pticos passivos, incluindo perda de inser\u00e7\u00e3o e varia\u00e7\u00e3o de perda, mas n\u00e3o estabelece um valor universal de perda de inser\u00e7\u00e3o para todos os divisores 1:N dispon\u00edveis no mercado. A especifica\u00e7\u00e3o do produto final continua sendo essencial.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-565ab1e2\">Ideal Loss x LuLeey <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/plc-splitter\/\" title=\"Ver todas as publica\u00e7\u00f5es na se\u00e7\u00e3o \u201cPLC Splitter\u201d\">Divisor PLC<\/a> Especifica\u00e7\u00f5es<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b2588a0e\">A diferen\u00e7a fica mais clara quando os valores te\u00f3ricos s\u00e3o comparados com produtos acabados espec\u00edficos:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Divisor<\/th><th>Perda ideal<\/th><th>Perda m\u00e1xima de inser\u00e7\u00e3o verificada<\/th><\/tr><\/thead><tbody><tr><td><a>Divisor de PLC 1\u00d78 SC\/APC<\/a><\/td><td>9,03 dB<\/td><td>\u226410,7 dB<\/td><\/tr><tr><td><a href=\"https:\/\/www.luleey.com\/pt\/produto\/1x16-plc-splitter-0-9mm-mini-module-sc-upc-single-mode\/\">Divisor PLC 1\u00d716 SC\/UPC<\/a><\/td><td>12,04 dB<\/td><td>\u226414,0 dB<\/td><\/tr><tr><td><a href=\"https:\/\/www.luleey.com\/pt\/produto\/1x32-plc-splitter-0-9mm-mini-module-sc-apc-single-mode\/\">Divisor de PLC 1\u00d732 SC\/APC<\/a><\/td><td>15,05 dB<\/td><td>\u226417,3 dB<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-09b38692\">Esses valores se aplicam \u00e0s vers\u00f5es espec\u00edficas de pacote e conector apresentadas nessas p\u00e1ginas. Outro tipo de divisor, op\u00e7\u00e3o de conector ou especifica\u00e7\u00e3o de produ\u00e7\u00e3o pode apresentar uma perda m\u00e1xima diferente.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9251e4e7\">Para fins de engenharia, utilize a perda de inser\u00e7\u00e3o m\u00e1xima verificada \u2014 e n\u00e3o o valor ideal nem um valor \u201ct\u00edpico\u201d apelativo.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-aa5de6ec\">Como os divisores em cascata afetam a perda<\/h2>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-1f2f39b6\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-21923\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/cascaded-plc-splitter-loss.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/cascaded-plc-splitter-loss.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/cascaded-plc-splitter-loss-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/cascaded-plc-splitter-loss-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/cascaded-plc-splitter-loss-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/cascaded-plc-splitter-loss-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/cascaded-plc-splitter-loss-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7bea1eb9\">Os divisores costumam ser instalados em duas etapas. Por exemplo:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8b2124d7\"><strong>1:4 na primeira etapa \u00d7 1:8 na segunda etapa = 1:32 no total<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-38c93065\">A perda ideal do divisor \u00e9 aditiva:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ba58c494\"><strong>6,02 dB + 9,03 dB = 15,05 dB<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-568dbc1a\">Isso equivale \u00e0 perda ideal de um \u00fanico divisor de 1:32, pois ambos os projetos dividem a pot\u00eancia de entrada original entre 32 sa\u00eddas.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b93d43ab\">O trajeto real em cascata pode ser diferente. Cada divisor possui sua pr\u00f3pria perda de inser\u00e7\u00e3o m\u00e1xima, e a conex\u00e3o entre os dois est\u00e1gios pode incluir adaptadores, conectores, emendas e fibra. Calcule a perda ao longo do trajeto exato at\u00e9 o assinante, em vez de multiplicar um valor gen\u00e9rico.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-60202752\">Se apenas uma sa\u00edda do divisor do primeiro est\u00e1gio alimentar o segundo est\u00e1gio, a perda no segundo est\u00e1gio afetar\u00e1 apenas os assinantes desse ramo. Desenhe o trajeto real antes de adicionar componentes.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-2b5ffcf1\">Como adicionar a perda do divisor a um <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/ftth-link-budget\/\" title=\"Ver todas as publica\u00e7\u00f5es sobre Or\u00e7amento de Link FTTH\">Or\u00e7amento de liga\u00e7\u00e3o FTTH<\/a><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-14002d9f\">Use esta estrutura:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6a65dffe\"><strong>Perda total prevista = perda no divisor + perda na fibra + perda no conector + perda na emenda + outras perdas passivas + margem de engenharia<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1d15c356\">Exemplos de premissas para um caminho:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Item<\/th><th>Valor de exemplo<\/th><\/tr><\/thead><tbody><tr><td>Perda m\u00e1xima de inser\u00e7\u00e3o do divisor 1\u00d732<\/td><td>17,3 dB<\/td><\/tr><tr><td>Atenua\u00e7\u00e3o da fibra para o trajeto e o comprimento de onda<\/td><td>2,2 dB<\/td><\/tr><tr><td>Margem para conectores e adaptadores<\/td><td>1,0 dB<\/td><\/tr><tr><td>Margem de emenda<\/td><td>0,5 dB<\/td><\/tr><tr><td>Margem de engenharia<\/td><td>3,0 dB<\/td><\/tr><tr><td><strong>Preju\u00edzo total previsto<\/strong><\/td><td><strong>24,0 dB<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7de4b1c1\">Esses n\u00fameros s\u00e3o apenas um exemplo. A atenua\u00e7\u00e3o da fibra varia de acordo com o comprimento de onda, enquanto o n\u00famero de conectores, a qualidade da emenda e a margem necess\u00e1ria variam de acordo com o projeto.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-26c54d26\">Ap\u00f3s calcular a perda prevista, estime a pot\u00eancia do receptor:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-842de1d1\"><strong>Pot\u00eancia estimada de recep\u00e7\u00e3o (dBm) = pot\u00eancia m\u00ednima de transmiss\u00e3o (dBm) \u2212 perda total prevista (dB)<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-79aab04d\">Compare esse resultado com a sensibilidade do receptor e os limites de sobrecarga do OLT, ONU, ONT ou m\u00f3dulo \u00f3ptico em quest\u00e3o. N\u00e3o existe uma \u00fanica faixa de pot\u00eancia \u00f3ptica aceit\u00e1vel para todos os <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/gpon\/\" title=\"Ver todos os posts em GPON\">GPON<\/a>, <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/xgs-pon\/\" title=\"Ver todas as mensagens em xgs-pon\">xgs-pon<\/a> ou sistema Ethernet.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ad30324a\">Se os termos dB e dBm ainda forem confusos, leia <a>dB x dBm em fibra \u00f3ptica<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-bbed0bbe\">Como escolher a propor\u00e7\u00e3o de desdobramento<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-ce7220cd\">1. Conte as sa\u00eddas necess\u00e1rias<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c0cfa81e\">Escolha um n\u00famero suficiente de sa\u00eddas para atender aos assinantes atuais e a uma expans\u00e3o realista. N\u00e3o opte por um modelo com maior capacidade apenas porque oferece mais portas; cada duplica\u00e7\u00e3o custa cerca de 3,01 dB do or\u00e7amento \u00f3ptico ideal.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-64eb1908\">2. Calcular cada est\u00e1gio do divisor<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4fa71574\">Para projetos em cascata, some a perda de inser\u00e7\u00e3o m\u00e1xima de cada divisor no caminho do assinante.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-8fb747ed\">3. Calcular ambas as dire\u00e7\u00f5es de transmiss\u00e3o<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3f3822b5\">Os sistemas PON utilizam comprimentos de onda diferentes para o sentido de envio e para o sentido de recep\u00e7\u00e3o. A atenua\u00e7\u00e3o da fibra e os limites de pot\u00eancia dos equipamentos podem variar de acordo com a dire\u00e7\u00e3o; portanto, verifique ambos os limites.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-de433a88\">4. Utilize as especifica\u00e7\u00f5es do equipamento para o pior cen\u00e1rio poss\u00edvel<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2acd4b55\">Utilize a pot\u00eancia m\u00ednima do transmissor, a perda m\u00e1xima dos componentes e os limites especificados para o receptor. N\u00e3o elabore o projeto com base em valores m\u00e9dios de laborat\u00f3rio.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-a99dd46b\">5. Incluir margem de seguran\u00e7a<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-14144695\">A margem leva em conta o envelhecimento, reparos, emendas adicionais, contamina\u00e7\u00e3o dos conectores, incerteza de medi\u00e7\u00e3o e altera\u00e7\u00f5es futuras. A margem necess\u00e1ria deve seguir a norma de projeto da operadora.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-d54feb78\">6. Selecione o conector e o pacote<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e062518a\">Confirme se \u00e9 SC\/APC ou SC\/UPC, cabos de fibra nua ou com conectores, constru\u00e7\u00e3o em minim\u00f3dulo ou montada em rack, tipo de fibra e caixa de instala\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-99785b1d\">LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/pt\/categoria-produto\/fiber-optic-cables\/optical-splitters-and-splitter-box\/\">divisores \u00f3pticos e caixas divisoras<\/a> incluem diversas propor\u00e7\u00f5es de divis\u00e3o, tipos de conectores e formatos de embalagem.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-1cc66938\">Como medir a perda de inser\u00e7\u00e3o de um divisor<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f82d0eea\">A Associa\u00e7\u00e3o de Fibra \u00d3ptica recomenda medir a perda ao longo do dispositivo e verificar a varia\u00e7\u00e3o entre as portas de sa\u00edda.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-571f78b6\">Um procedimento b\u00e1sico \u00e9 o seguinte:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Utilize uma fonte \u00f3ptica calibrada e um medidor de pot\u00eancia adequados ao comprimento de onda do teste.<\/li>\n\n\n\n<li>Limpe e inspecione os cabos de refer\u00eancia e os conectores do divisor.<\/li>\n\n\n\n<li>Estabele\u00e7a uma refer\u00eancia v\u00e1lida sem o divisor no caminho.<\/li>\n\n\n\n<li>Conecte a fonte \u00e0 entrada do divisor.<\/li>\n\n\n\n<li>Me\u00e7a todas as portas de sa\u00edda utilizando a mesma configura\u00e7\u00e3o de refer\u00eancia.<\/li>\n\n\n\n<li>Calcule a perda de inser\u00e7\u00e3o para cada sa\u00edda.<\/li>\n\n\n\n<li>Compare a maior perda medida e a uniformidade da porta com as especifica\u00e7\u00f5es exatas do produto.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b17b4508\">N\u00e3o avalie um divisor com base em uma \u00fanica sa\u00edda convenientemente selecionada. Um teste completo verifica todas as sa\u00eddas, pois a uniformidade faz parte do desempenho do divisor.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-431aee49\">Para os testes formais de aceita\u00e7\u00e3o, siga o m\u00e9todo da operadora, a disposi\u00e7\u00e3o do cabo de refer\u00eancia, os requisitos de comprimento de onda e o procedimento de calibra\u00e7\u00e3o do instrumento.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-9a243bf5\">Erros comuns relacionados \u00e0 perda no divisor<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-ce777248\">Erro 1: Considerar 1:8 como 8 dB<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a340b03b\">Um divisor igual de 1:8 apresenta uma perda ideal de 9,03 dB, e n\u00e3o de 8 dB.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-0541bb15\">Erro 2: Utilizar a perda ideal como especifica\u00e7\u00e3o do produto<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-15ed261c\">A perda ideal descreve a divis\u00e3o matem\u00e1tica perfeita. O divisor finalizado apresenta uma perda de inser\u00e7\u00e3o especificada mais elevada.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-cbf5ec8b\">Erro 3: Usar um valor t\u00edpico para um projeto no pior cen\u00e1rio poss\u00edvel<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c212121e\">A perda t\u00edpica pode descrever o desempenho m\u00e9dio. Utilize a perda de inser\u00e7\u00e3o m\u00e1xima garantida ao verificar se todas as unidades e caminhos de sa\u00edda permitidos estar\u00e3o dentro do or\u00e7amento.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-c766fd49\">Erro 4: Esquecer o segundo est\u00e1gio do divisor<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a313933f\">Um projeto em cascata deve incluir todos os divisores e conex\u00f5es no trajeto do assinante.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-70998204\">Erro 5: Ignorar a porta de sa\u00edda mais fraca<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b1f3c879\">A uniformidade das portas significa que uma sa\u00edda pode apresentar mais perda do que outra. Fa\u00e7a a medi\u00e7\u00e3o ou o projeto levando em conta a porta com a pior perda permitida.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-e1523149\">Erro 6: Considerar a perda no divisor como perda total do link<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-80a5960a\">O divisor \u00e9 apenas uma parte do caminho \u00f3ptico. A fibra, os conectores, as emendas, os componentes WDM e a margem de engenharia tamb\u00e9m consomem recursos do or\u00e7amento.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-db9f3735\">Resposta final<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-001c309b\">A perda no divisor de fibra \u00f3ptica come\u00e7a com a f\u00f3rmula ideal:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4d22989c\"><strong>Perda ideal do divisor = 10 \u00d7 log10(N)<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-761d9ae5\">Isso d\u00e1 aproximadamente:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>1:2 = 3,01 dB<\/li>\n\n\n\n<li>1:4 = 6,02 dB<\/li>\n\n\n\n<li>1:8 = 9,03 dB<\/li>\n\n\n\n<li>1:16 = 12,04 dB<\/li>\n\n\n\n<li>1:32 = 15,05 dB<\/li>\n\n\n\n<li>1:64 = 18,06 dB<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0e137732\">Os divisores reais apresentam maior perda de inser\u00e7\u00e3o. Para um projeto confi\u00e1vel de FTTH ou PON, utilize a perda m\u00e1xima indicada na ficha t\u00e9cnica exata do produto, some todos os est\u00e1gios em cascata e componentes passivos, inclua a margem de seguran\u00e7a e compare o resultado com as especifica\u00e7\u00f5es exatas do transmissor e do receptor.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-285d2db1\">Ao solicitar uma configura\u00e7\u00e3o de divisor \u00e0 LuLeey, forne\u00e7a a rela\u00e7\u00e3o de divis\u00e3o, o polimento do conector, o tipo de embalagem, o n\u00famero de est\u00e1gios, os comprimentos de onda operacionais e o or\u00e7amento de enlace alvo. Esses detalhes s\u00e3o mais \u00fateis do que simplesmente pedir um \u201cdivisor de baixa perda\u201d.\u201d<\/p>","protected":false},"excerpt":{"rendered":"<p>Rela\u00e7\u00e3o de divis\u00e3o Pot\u00eancia ideal por sa\u00edda Perda ideal exata Perda ideal arredondada Exemplo de FOA: perda de inser\u00e7\u00e3o t\u00edpica* 1:2 50% 3,01 dB<\/p>","protected":false},"author":1,"featured_media":21922,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[885],"tags":[41,1457,1456,1459,1455,1458,79],"class_list":["post-21921","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-access-network","tag-gpon","tag-fiber-optic-splitter-loss","tag-ftth-link-budget","tag-optical-loss","tag-plc-splitter","tag-pon-splitter","tag-xgs-pon"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts\/21921","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/comments?post=21921"}],"version-history":[{"count":1,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts\/21921\/revisions"}],"predecessor-version":[{"id":21924,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts\/21921\/revisions\/21924"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/media\/21922"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/media?parent=21921"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/categories?post=21921"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/tags?post=21921"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}