{"id":22027,"date":"2026-08-30T23:15:48","date_gmt":"2026-08-30T15:15:48","guid":{"rendered":"https:\/\/www.luleey.com\/?p=22027"},"modified":"2026-08-30T23:15:51","modified_gmt":"2026-08-30T15:15:51","slug":"can-you-use-two-identical-bidi-sfp-modules-together","status":"publish","type":"post","link":"https:\/\/www.luleey.com\/pt\/can-you-use-two-identical-bidi-sfp-modules-together\/","title":{"rendered":"\u00c9 poss\u00edvel usar dois m\u00f3dulos SFP BiDi id\u00eanticos ao mesmo tempo?"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-9fc0c9c2\">Na maioria dos links Ethernet de fibra \u00fanica mais comuns, <strong>dois id\u00eanticos <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/bidi-sfp\/\" title=\"Ver todas as publica\u00e7\u00f5es em BiDi SFP\">SFP BiDi<\/a> m\u00f3dulos<\/strong> n\u00e3o funcionar\u00e3o juntos. Se ambos os m\u00f3dulos transmitirem no mesmo comprimento de onda e receberem no mesmo outro comprimento de onda, nenhum dos receptores captar\u00e1 o sinal para o qual foi projetado.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8070d87e\">Normalmente, \u00e9 necess\u00e1rio um par complementar. Por exemplo, um m\u00f3dulo identificado como TX1310nm\/RX1550nm precisa de um m\u00f3dulo oposto identificado como TX1550nm\/RX1310nm.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-93019720\">Os m\u00f3dulos tamb\u00e9m devem ser compat\u00edveis quanto \u00e0 aplica\u00e7\u00e3o de dados, taxa de linha, classe de alcance, conector e tipo de fibra. Ambas as portas do host devem suportar o modo el\u00e9trico e a codifica\u00e7\u00e3o do m\u00f3dulo exigidos.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-eec46cd5\">\u201cAs indica\u00e7\u00f5es \u201dA\/B\u201c, \u201dU\/D\u201d e as etiquetas coloridas podem ajudar, mas o m\u00e9todo mais seguro \u00e9 comparar as especifica\u00e7\u00f5es reais dos comprimentos de onda de transmiss\u00e3o (TX) e recep\u00e7\u00e3o (RX).<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-f5cf69c6\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22029\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-matched-pair-hero.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-matched-pair-hero.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-matched-pair-hero-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-matched-pair-hero-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-matched-pair-hero-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-matched-pair-hero-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-matched-pair-hero-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ad92ef52\"><\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-6b46164d\">Dois m\u00f3dulos SFP BiDi id\u00eanticos: resposta r\u00e1pida<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>M\u00f3dulo local<\/th><th>M\u00f3dulo remoto<\/th><th>Resultado do comprimento de onda<\/th><th>Resultado esperado<\/th><\/tr><\/thead><tbody><tr><td>TX1310\/RX1550<\/td><td>TX1310\/RX1550<\/td><td>Ambos transmitem na frequ\u00eancia 1310; ambos escutam na frequ\u00eancia 1550<\/td><td>N\u00e3o h\u00e1 link normal<\/td><\/tr><tr><td>TX1310\/RX1550<\/td><td>TX1550\/RX1310<\/td><td>Cada TX corresponde a um RX<\/td><td>O emparelhamento de comprimentos de onda est\u00e1 correto<\/td><\/tr><tr><td>TX1270\/RX1330<\/td><td>TX1330\/RX1270<\/td><td>Cada TX corresponde a um RX<\/td><td>O emparelhamento de comprimentos de onda est\u00e1 correto<\/td><\/tr><tr><td>TX1310\/RX1550 a 1G<\/td><td>TX1550\/RX1310 a 2,5 G<\/td><td>Os comprimentos de onda se complementam, mas as frequ\u00eancias n\u00e3o<\/td><td>N\u00e3o h\u00e1 link normal<\/td><\/tr><tr><td>Comprimentos de onda complementares, mas classes de pot\u00eancia diferentes<\/td><td>Os comprimentos de onda podem coincidir<\/td><td>O balan\u00e7o \u00f3ptico pode estar inv\u00e1lido<\/td><td>Verifique as especifica\u00e7\u00f5es exatas<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3a123bbb\">Os comprimentos de onda corretos s\u00e3o necess\u00e1rios, mas n\u00e3o suficientes. Uma conex\u00e3o efetiva tamb\u00e9m depende do modo SerDes do host, da taxa de aplica\u00e7\u00e3o, da codifica\u00e7\u00e3o do m\u00f3dulo, da fibra, das condi\u00e7\u00f5es do conector e da pot\u00eancia recebida.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-d0ecb218\">Como um SFP BiDi utiliza um fio de fibra \u00f3ptica<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e48ac384\">Um link \u00f3ptico duplex normal utiliza uma fibra para cada sentido. Um m\u00f3dulo BiDi de fibra \u00fanica combina seu transmissor e receptor em uma \u00fanica fibra por meio de um componente \u00f3ptico interno seletivo em comprimento de onda.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a1fa330d\">Um comprimento de onda se desloca do Lado A para o Lado B, enquanto um comprimento de onda diferente se desloca do Lado B para o Lado A.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1c768b39\">Para um par comum espec\u00edfico de um fornecedor:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>O lado A transmite na frequ\u00eancia de 1310 nm e recebe na frequ\u00eancia de 1550 nm.<\/li>\n\n\n\n<li>O lado B transmite na frequ\u00eancia de 1550 nm e recebe na frequ\u00eancia de 1310 nm.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-09cbc3da\">Outros produtos utilizam esquemas de comprimentos de onda diferentes. A Cisco documenta o 1000BASE-BX10-U como TX1310\/RX1490 e o BX10-D como TX1490\/RX1310. Seus produtos 10G BXU\/BXD utilizam 1270 nm e 1330 nm em dire\u00e7\u00f5es opostas. <a href=\"https:\/\/www.cisco.com\/c\/en\/us\/products\/collateral\/interfaces-modules\/gigabit-ethernet-gbic-sfp-modules\/datasheet-c78-366584.html\" target=\"_blank\" rel=\"noopener\">Especifica\u00e7\u00f5es do Cisco 1G BiDi<\/a>, <a href=\"https:\/\/www.cisco.com\/c\/en\/us\/products\/collateral\/interfaces-modules\/transceiver-modules\/data_sheet_c78-455693.html\" target=\"_blank\" rel=\"noopener\">Especifica\u00e7\u00f5es do Cisco 10G BiDi<\/a><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-fa17c5ca\">N\u00e3o presuma que todos os pares BiDi utilizam 1310\/1550 nm. Leia a ficha t\u00e9cnica e o r\u00f3tulo com aten\u00e7\u00e3o.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-4434d3f2\">Por que dois m\u00f3dulos do mesmo lado costumam apresentar falhas<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-97a286c9\">Suponha que ambas as extremidades utilizem m\u00f3dulos TX1310\/RX1550.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-aaec5c9f\">No lado local, o receptor \u00e9 filtrado para 1550 nm. O m\u00f3dulo remoto transmite em 1310 nm, de modo que o receptor local n\u00e3o recebe o comprimento de onda pretendido.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d38ccc01\">A mesma incompatibilidade ocorre na dire\u00e7\u00e3o oposta. Ambos os transmissores enviam 1310 nm, enquanto ambos os receptores aguardam 1550 nm.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-945cd1db\">O interruptor ainda pode:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Detectar o m\u00f3dulo EEPROM<\/li>\n\n\n\n<li>Exibir o fornecedor e o n\u00famero da pe\u00e7a<\/li>\n\n\n\n<li>Informar a temperatura, a tens\u00e3o ou a pot\u00eancia de transmiss\u00e3o<\/li>\n\n\n\n<li>Mostrar que o laser est\u00e1 ativado<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0afb3efa\">Nenhuma dessas situa\u00e7\u00f5es comprova que o comprimento de onda \u00f3ptico remoto chegue ao receptor correto. A detec\u00e7\u00e3o do m\u00f3dulo e a comunica\u00e7\u00e3o DDM s\u00e3o independentes do tr\u00e1fego \u00f3ptico bem-sucedido.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-e700bcac\">\u201cId\u00eantico\u201d significa sempre que o link n\u00e3o funciona?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-523536c7\">No caso dos SFPs BiDi de comprimento de onda fixo comuns discutidos aqui, dois m\u00f3dulos id\u00eanticos do mesmo lado normalmente n\u00e3o formam um link.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-29675325\">No entanto, isso n\u00e3o deve ser interpretado como uma afirma\u00e7\u00e3o universal sobre todos os produtos denominados \u201cBiDi\u201d. Alguns transceptores avan\u00e7ados utilizam m\u00faltiplas faixas, comprimentos de onda sintoniz\u00e1veis, sele\u00e7\u00e3o autom\u00e1tica de fun\u00e7\u00e3o ou arquiteturas propriet\u00e1rias.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1a536739\">A regra pr\u00e1tica confi\u00e1vel \u00e9:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-bb1e31cc\"><strong>Para um m\u00f3dulo de fibra \u00fanica de comprimento de onda fixo, compare o TX em uma extremidade com o RX na outra, em ambas as dire\u00e7\u00f5es.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5c419c7c\">N\u00e3o tome sua decis\u00e3o apenas com base nas siglas SFP, SFP+, BiDi, WDM, A, B, U ou D.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-1723a21e\">Os termos \u201cA\/B\u201d e \u201cU\/D\u201d n\u00e3o s\u00e3o defini\u00e7\u00f5es universais<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8bb9632d\">Os fornecedores podem utilizar:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Lado A e Lado B<\/li>\n\n\n\n<li><a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/bx-u\/\" title=\"Ver todas as publica\u00e7\u00f5es no BX-U\">BX-U<\/a> e <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/bx-d\/\" title=\"Ver todas as publica\u00e7\u00f5es no BX-D\">BX-D<\/a><\/li>\n\n\n\n<li>A montante e a jusante<\/li>\n\n\n\n<li>WDM-A e WDM-B<\/li>\n\n\n\n<li>Linguetas ou etiquetas coloridas<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8e827ac1\">Esses nomes ajudam a identificar um conjunto correspondente, mas n\u00e3o s\u00e3o mapeamentos universais de comprimentos de onda.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5f0a9c05\">O par BX10-U\/D de 1G da Cisco utiliza 1310 nm e 1490 nm, enquanto o par BXU\/D de 10G utiliza 1270 nm e 1330 nm. Um produto de 1,25G de outro fabricante pode utilizar 1310 nm e 1550 nm.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b913953b\">Nunca combine m\u00f3dulos apenas porque um indica \u201cA\u201d e o outro indica \u201cB\u201d. Verifique as especifica\u00e7\u00f5es \u00f3pticas, bem como as linhas de comprimento de onda de transmiss\u00e3o (TX) e recep\u00e7\u00e3o (RX), a taxa de transmiss\u00e3o e o alcance.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-bfa270e1\">O que mais precisa coincidir, al\u00e9m do comprimento de onda?<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-8942f6b0\">1. Utiliza\u00e7\u00e3o de dados e taxa de transmiss\u00e3o real<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0d10e550\">Tanto os m\u00f3dulos quanto os hosts devem operar no mesmo modo exigido. Um m\u00f3dulo de 1G e um m\u00f3dulo de 2,5G, mesmo que sejam complementares, n\u00e3o estabelecem uma conex\u00e3o funcional apenas porque seus comprimentos de onda coincidem.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9a193df4\">O fato de o slot f\u00edsico para SFP ou SFP+ ser compat\u00edvel n\u00e3o garante a compatibilidade de velocidade. Verifique o modo SerDes do host, o firmware, o driver e a configura\u00e7\u00e3o da porta.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-d8584eb7\">2. Tipo de fibra<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-86d9fead\">Os m\u00f3dulos LuLeey mencionados aqui s\u00e3o especificados para fibra monomodo. N\u00e3o substitua por fibra multimodo apenas com base na compatibilidade do conector.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-bf8933d8\">3. Tipo e acabamento do conector<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ab0e97e9\">LC simplex e SC simplex s\u00e3o interfaces f\u00edsicas diferentes. As faces finais UPC e APC n\u00e3o devem ser acopladas diretamente.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-95391b21\">4. Classe de alcance e or\u00e7amento \u00f3ptico<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f31ce834\">Indica\u00e7\u00f5es de dist\u00e2ncia, como 10 km, 20 km e 40 km, descrevem uma classe de alcance prevista, e n\u00e3o uma garantia para todas as rotas.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c613697c\">Verifique:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Sa\u00edda m\u00ednima e m\u00e1xima do transmissor<\/li>\n\n\n\n<li>Sensibilidade do receptor<\/li>\n\n\n\n<li>Sobrecarga do receptor ou entrada m\u00e1xima<\/li>\n\n\n\n<li>Perda real na fibra, no conector e na emenda<\/li>\n\n\n\n<li>Qualquer atenua\u00e7\u00e3o m\u00ednima exigida<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-36579499\">N\u00e3o emparelhe m\u00f3dulos apenas porque ambas as embalagens indicam \u201c20 km\u201d.\u201d<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-0aee66cd\">5. Reconhecimento e codifica\u00e7\u00e3o do hospedeiro<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2da27b37\">Alguns switches aceitam codifica\u00e7\u00e3o gen\u00e9rica; outros exibem avisos ou rejeitam transceptores n\u00e3o compat\u00edveis. Verifique o modelo exato do switch, roteador, placa de rede ou conversor de m\u00eddia, bem como o firmware.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-345e8835\">6. Ambiente operacional<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-dafa8e52\">Os m\u00f3dulos comerciais e industriais podem ter faixas de temperatura nominais diferentes. \u00c9 importante considerar o ambiente real de instala\u00e7\u00e3o, e n\u00e3o apenas o comprimento de onda.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-1f8ea9f3\">Como ler uma etiqueta do m\u00f3dulo BiDi<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e80eb618\">Considere este exemplo:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-64473b4f\"><strong>1,25 G, TX 1.310 nm\/RX 1.550 nm, SMF, 20 km, LC, DDM<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6e0cf6b0\">Interprete isso como seis cheques separados:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>1,25 G:<\/strong> finalidade de uso e taxa de aplica\u00e7\u00e3o no hospedeiro.<\/li>\n\n\n\n<li><strong>TX1310nm:<\/strong> comprimento de onda ao sair deste m\u00f3dulo.<\/li>\n\n\n\n<li><strong>RX1550nm:<\/strong> comprimento de onda esperado por este m\u00f3dulo.<\/li>\n\n\n\n<li><strong>SMF:<\/strong> requisito de fibra monomodo.<\/li>\n\n\n\n<li><strong>20 km:<\/strong> atingir a meta dentro do or\u00e7amento especificado.<\/li>\n\n\n\n<li><strong>LC e DDM:<\/strong> conector e capacidade de diagn\u00f3stico.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-66d640ac\">O m\u00f3dulo oposto deve, normalmente, apresentar os valores TX 1550 nm\/RX 1310 nm, al\u00e9m de atender \u00e0s demais condi\u00e7\u00f5es exigidas.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-43f480f8\">Se o r\u00f3tulo indicar apenas um comprimento de onda, procure a ficha t\u00e9cnica completa. Um \u00fanico comprimento de onda indicado para fins de marketing pode se referir apenas ao transmissor.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-cebd1289\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22028\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-no-link-checklist.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-no-link-checklist.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-no-link-checklist-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-no-link-checklist-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-no-link-checklist-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-no-link-checklist-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/08\/bidi-sfp-no-link-checklist-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-1c2127ba\">Solu\u00e7\u00e3o de problemas de aus\u00eancia de conex\u00e3o no SFP BiDi<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-0ca37ed6\">Passo 1: Anote os n\u00fameros exatos das pe\u00e7as<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-452de152\">N\u00e3o escreva apenas \u201cdois m\u00f3dulos BiDi de 1G\u201d. Registre tanto as etiquetas quanto os modelos dos hosts, o firmware e as velocidades configuradas.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-f92f383e\">Etapa 2: Criar uma tabela de comprimentos de onda bidirecional<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Dire\u00e7\u00e3o<\/th><th>Transmissor<\/th><th>Receptor<\/th><th>\u00c9 o mesmo?<\/th><\/tr><\/thead><tbody><tr><td>Local para remoto<\/td><td>Local TX<\/td><td>Receptor remoto<\/td><td>Sim\/N\u00e3o<\/td><\/tr><tr><td>Remoto para local<\/td><td>Transmiss\u00e3o remota<\/td><td>RX local<\/td><td>Sim\/N\u00e3o<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1e7fc54e\">Ambas as linhas devem coincidir.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-e75ff5c2\">Etapa 3: Verificar a taxa e o modo de host<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2bcf0b4a\">Verifique as velocidades de porta configuradas e reais. Confirme se ambos os hosts oferecem o modo exigido pelos m\u00f3dulos.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a5093b21\">No caso dos m\u00f3dulos de 2,5G, n\u00e3o se deve presumir que um compartimento SFP+ ofere\u00e7a velocidade de 2,5G. O chipset ou PHY do host, o firmware, o driver e a configura\u00e7\u00e3o da porta devem ser compat\u00edveis com esse modo SerDes.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-00649e45\">Etapa 4: Verifique o trajeto da fibra<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-aaf85c48\">Verifique se o cabo \u00e9 monomodo, se chega ao ponto final pretendido e se n\u00e3o passa por um divisor, filtro ou rede PON incompat\u00edvel.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7345c35f\">Um par BiDi de Ethernet ponto a ponto n\u00e3o substitui um par de ONU e OLT de GPON ou XGS-PON.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-4fe1be19\">Etapa 5: Inspecione e limpe os dois conectores<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1d396218\">Utilize um processo de inspe\u00e7\u00e3o-limpeza-inspe\u00e7\u00e3o com ferramentas adequadas para LC ou SC e o polidor de conectores. Nunca olhe diretamente para uma fibra ativa.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-d0ec4b65\">Passo 6: Leia o DDM na dire\u00e7\u00e3o correta<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-78882a5c\">Compare a leitura de transmiss\u00e3o (TX) do m\u00f3dulo remoto com a leitura de recep\u00e7\u00e3o (RX) do m\u00f3dulo local. Repita o procedimento na dire\u00e7\u00e3o oposta.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a294ccdb\">Um valor RX indicado como \u201csem sinal\u201d ou \u201cmuito baixo\u201d pode corroborar o diagn\u00f3stico, mas a precis\u00e3o do DDM depende do m\u00f3dulo e do host.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-83febded\">Etapa 7: Comparar a pot\u00eancia com os limites exatos<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ed1f75a3\">Se os comprimentos de onda e as taxas estiverem corretos, compare a pot\u00eancia de recep\u00e7\u00e3o com a sensibilidade do receptor e os limites de sobrecarga. Uma intensidade de luz muito baixa ou muito alta pode impedir o funcionamento confi\u00e1vel.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-d8b18a27\">Etapa 8: Testar um par verificado<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4135cb8e\">Utilize um par complementar de qualidade comprovada, com a codifica\u00e7\u00e3o e o alcance corretos. Altere uma vari\u00e1vel por vez e registre o resultado.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-b599e1da\">Exemplo com os m\u00f3dulos SFP BiDi da LuLeey<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a16cc2ad\">LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/pt\/produto\/1-25g-bidi-sfp-module-gigabit-sc-smf-10km-ddm-transceiver-pair\/\">Par de m\u00f3dulos SFP BiDi SC de 1,25 G para 10 km<\/a> est\u00e1 listado como um par compat\u00edvel de 1310\/1550 nm que utiliza uma fibra monomodo, uma interface SC simplex e DDM. A p\u00e1gina do produto informa que o TX1310\/RX1550 deve ser emparelhado com o TX1550\/RX1310.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-86fe1aad\">Para um host de 2,5G, o LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/pt\/produto\/2-5g-sc-smf-sfp-module-support-bidi\/\">SFP BiDi SC de 2,5G para 20 km<\/a> est\u00e1 listado para um par complementar de 1310\/1550 nm, conector SC simplex e fibra monomodo.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-401df3cf\">A p\u00e1gina do produto 2,5G tamb\u00e9m indica que o host deve ser compat\u00edvel com a opera\u00e7\u00e3o de SFP de 2,5G. N\u00e3o fa\u00e7a o pedido para uma porta fixa de 1G nem presuma que todas as portas SFP+ de 10G sejam compat\u00edveis com 2,5G nativo.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a7ec2ce2\">Antes de fazer o pedido, forne\u00e7a:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Tanto os modelos de host quanto o firmware<\/li>\n\n\n\n<li>Taxa de dados exigida<\/li>\n\n\n\n<li>Requisitos de codifica\u00e7\u00e3o local e remota<\/li>\n\n\n\n<li>Tipo de fibra e n\u00famero de n\u00facleos dispon\u00edveis<\/li>\n\n\n\n<li>Conector e polimento em cada extremidade<\/li>\n\n\n\n<li>Dist\u00e2ncia do trajeto e perda estimada<\/li>\n\n\n\n<li>Faixa de temperatura exigida<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-2ee990fc\">Resposta final<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-690f3d1a\">Dois m\u00f3dulos SFP BiDi de comprimento de onda fixo id\u00eanticos normalmente n\u00e3o funcionam juntos, pois as dire\u00e7\u00f5es dos comprimentos de onda de transmiss\u00e3o (TX) e recep\u00e7\u00e3o (RX) s\u00e3o as mesmas.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9a2b1213\">Use um par complementar no qual:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>O TX local \u00e9 igual ao RX remoto.<\/li>\n\n\n\n<li>A transmiss\u00e3o remota \u00e9 igual \u00e0 recep\u00e7\u00e3o local.<\/li>\n\n\n\n<li>Ambas as extremidades utilizam a mesma taxa de aplica\u00e7\u00e3o.<\/li>\n\n\n\n<li>Ambos os hosts suportam o modo SerDes e a codifica\u00e7\u00e3o exigidos.<\/li>\n\n\n\n<li>A fibra, o conector, o alcance e a pot\u00eancia \u00f3ptica s\u00e3o compat\u00edveis.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9b37bfa1\">N\u00e3o basta que as palavras \u201cBiDi\u201d e \u201c20 km\u201d coincidam. O link bidirecional completo deve coincidir.<\/p>","protected":false},"excerpt":{"rendered":"<p>M\u00f3dulo local M\u00f3dulo remoto Resultado do comprimento de onda Resultado esperado TX1310\/RX1550 TX1310\/RX1550 Ambos transmitem em 1310; ambos escutam em 1550 N\u00e3o h\u00e1 conex\u00e3o normal<\/p>","protected":false},"author":1,"featured_media":22029,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[887],"tags":[1382,1386,1496,1495,1497,1494,1493,1492],"class_list":["post-22027","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-data-transmission-conversion","tag-optical-transceiver","tag-bidi-sfp","tag-bx-d","tag-bx-u","tag-fiber-link-troubleshooting","tag-sfp-wavelength","tag-single-fiber-sfp","tag-wdm-sfp-2"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts\/22027","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/comments?post=22027"}],"version-history":[{"count":1,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts\/22027\/revisions"}],"predecessor-version":[{"id":22030,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts\/22027\/revisions\/22030"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/media\/22029"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/media?parent=22027"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/categories?post=22027"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/tags?post=22027"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}