{"id":22361,"date":"2026-09-24T12:37:44","date_gmt":"2026-09-24T04:37:44","guid":{"rendered":"https:\/\/www.luleey.com\/?p=22361"},"modified":"2026-09-23T12:59:19","modified_gmt":"2026-09-23T04:59:19","slug":"sfp-rx-los-vs-tx-fault-what-each-alarm-means","status":"publish","type":"post","link":"https:\/\/www.luleey.com\/pt\/sfp-rx-los-vs-tx-fault-what-each-alarm-means\/","title":{"rendered":"SFP: Falha de LOS (Perda de Sinal) na recep\u00e7\u00e3o vs. falha na transmiss\u00e3o: o que cada alarme significa"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-9ece3cbf\"><strong><a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/sfp\/\" title=\"Ver todas as mensagens em SFP\">SFP<\/a> <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/rx-los\/\" title=\"Ver todas as publica\u00e7\u00f5es no RX LOS\">RX LOS<\/a> vs <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/tx-fault\/\" title=\"Ver todas as publica\u00e7\u00f5es no TX Fault\">Falha TX<\/a><\/strong> \u00c9 uma pergunta direcionada para o diagn\u00f3stico de falhas, e n\u00e3o se trata de dois nomes para a mesma falha. \u201cRX LOS\u201d significa que o m\u00f3dulo local est\u00e1 relatando uma condi\u00e7\u00e3o de perda de sinal na recep\u00e7\u00e3o. \u201cTX Fault\u201d significa que o m\u00f3dulo local est\u00e1 relatando um problema no lado do transmissor.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-90a88710\">Nenhum desses status, por si s\u00f3, comprova que o transceptor como um todo esteja com defeito. Comece pela extremidade que reporta o status, identifique a dire\u00e7\u00e3o afetada e, em seguida, teste uma parte dessa dire\u00e7\u00e3o de cada vez.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2aafb900\">Este guia aborda os m\u00f3dulos SFP comuns para Ethernet \u00f3ptica ponto a ponto e <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/sfp-2\/\" title=\"Ver todos os posts em SFP+\">SFP+<\/a> links. Os nomes exatos das conex\u00f5es, a polaridade e a exposi\u00e7\u00e3o do status podem variar de acordo com o m\u00f3dulo e o host; portanto, consulte os manuais do hardware espec\u00edfico.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-36b3e9d8\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22362\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-vs-tx-fault-hero-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-847767e5\">SFP: Falha de LOS na recep\u00e7\u00e3o versus falha na transmiss\u00e3o: a diferen\u00e7a de um minuto<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3546919a\">Suponha-se uma conex\u00e3o duplex simples entre o dispositivo A e o dispositivo B.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Status exibido no dispositivo B<\/th><th>O que o m\u00f3dulo est\u00e1 informando<\/th><th>Primeira linha de investiga\u00e7\u00e3o a ser analisada<\/th><th>O que isso n\u00e3o prova<\/th><\/tr><\/thead><tbody><tr><td>RX LOS ativado<\/td><td>O receptor de B n\u00e3o detecta um sinal recebido aceit\u00e1vel<\/td><td>Um transmissor \u2192 Trajeto de fibra de A a B \u2192 Um receptor em B<\/td><td>O receptor do B est\u00e1, sem d\u00favida, com defeito<\/td><\/tr><tr><td>Falha TX detectada<\/td><td>O m\u00f3dulo B sinaliza uma falha no transmissor local<\/td><td>Alimenta\u00e7\u00e3o\/controle do host B \u2192 transmissor do m\u00f3dulo B<\/td><td>A fibra B-A est\u00e1 quebrada<\/td><\/tr><tr><td>Ambos afirmaram<\/td><td>B apresenta uma falha local no transmissor e tamb\u00e9m n\u00e3o est\u00e1 recebendo um sinal aceit\u00e1vel<\/td><td>Analise as dire\u00e7\u00f5es separadamente e, em seguida, verifique a pot\u00eancia compartilhada, a configura\u00e7\u00e3o e o estado dos m\u00f3dulos<\/td><td>O corte de uma \u00fanica fibra explica todos os sintomas<\/td><\/tr><tr><td>Nenhuma das duas afirma\u00e7\u00f5es foi comprovada, mas o link est\u00e1 fora do ar<\/td><td>Esses dois sinais de status n\u00e3o identificam a causa<\/td><td>PMD, taxa, FEC, modo de host, codifica\u00e7\u00e3o, polaridade e estado do par<\/td><td>A configura\u00e7\u00e3o f\u00edsica e el\u00e9trica \u00e9 compat\u00edvel<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6095e855\">A corrente <a href=\"https:\/\/members.snia.org\/document\/dl\/25880\" target=\"_blank\" rel=\"noopener\">Especifica\u00e7\u00e3o SNIA SFF-8419<\/a> mapas <code>Tx_Fault<\/code> como a sa\u00edda de falha do transmissor do m\u00f3dulo e <code>Rx_LOS<\/code> como indica\u00e7\u00e3o de perda de sinal no receptor. Na Ethernet, o sinal de recep\u00e7\u00e3o tamb\u00e9m pode ser apresentado como <strong>Detec\u00e7\u00e3o de sinal<\/strong>. Um apresentador pode, portanto, descrever a mesma condi\u00e7\u00e3o subjacente usando uma formula\u00e7\u00e3o positiva ou negativa, como, por exemplo, <code>RX LOS: Sim<\/code> ou <code>Detec\u00e7\u00e3o de sinal: N\u00e3o<\/code>.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3f341e3c\">N\u00e3o interprete algo desconhecido <code>Falha no RX<\/code> etiqueta at\u00e9 que o manual da plataforma especifique se isso significa perda de linha de vis\u00e3o (LOS) na recep\u00e7\u00e3o, baixa pot\u00eancia de recep\u00e7\u00e3o, uma falha no PCS ou uma condi\u00e7\u00e3o combinada diferente.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-faabc045\">O RX LOS aponta de volta para a dire\u00e7\u00e3o de aproxima\u00e7\u00e3o<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-258b847d\">Se o dispositivo B assinalar RX LOS, comece pela dire\u00e7\u00e3o \u00f3ptica que deveria chegar ao B:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8332752b\"><strong>A TX \u2192 conector A \u2192 trajeto da fibra \u2192 conector B \u2192 B RX<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-96271753\">As poss\u00edveis causas incluem um transmissor desativado ou com falha em A, polaridade duplex invertida, um conector desconectado ou contaminado, perda excessiva no trajeto, tipo de fibra incorreto, comprimentos de onda ou PMDs incompat\u00edveis, um par BiDi A\/B incorreto ou um problema no receptor de B. O RX LOS restringe a dire\u00e7\u00e3o; ele n\u00e3o identifica um \u00fanico componente com falha.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1b834363\">Verifique a dire\u00e7\u00e3o oposta separadamente. \u00c9 poss\u00edvel que B n\u00e3o receba nada de A, enquanto A continua recebendo normalmente de B. Um \u00fanico \u00edcone de \u201cLink Down\u201d muitas vezes oculta essa diferen\u00e7a direcional.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-36b41886\">Para um link duplex, verifique se cada transmissor alcan\u00e7a o receptor oposto. Para BiDi de fibra \u00fanica, verifique se os comprimentos de onda de transmiss\u00e3o e recep\u00e7\u00e3o s\u00e3o complementares; dois m\u00f3dulos na mesma dire\u00e7\u00e3o n\u00e3o constituem um par normal.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-773f86cd\">A falha TX \u00e9 localizada no lado do transmissor<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b18959a0\">Se o dispositivo B sinalizar uma falha de transmiss\u00e3o (TX Fault), concentre-se primeiro no m\u00f3dulo B e na forma como o host desse m\u00f3dulo alimenta e controla o transmissor. Verifique se o host sinalizou intencionalmente a desativa\u00e7\u00e3o da transmiss\u00e3o (TX Disable), se os dados de diagn\u00f3stico est\u00e3o v\u00e1lidos ap\u00f3s a inicializa\u00e7\u00e3o e se a tens\u00e3o, a temperatura ou qualquer outro aviso do transmissor est\u00e1 fora do normal para esse m\u00f3dulo espec\u00edfico.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-de56146d\">\u201cTX Disable\u201d e \u201cTX Fault\u201d s\u00e3o sinais diferentes. \u201cTX Disable\u201d \u00e9 um comando de controle do host para o m\u00f3dulo que desativa o transmissor. \u201cTX Fault\u201d \u00e9 um sinal de status do m\u00f3dulo para o host. Um transmissor desativado pode fazer com que o lado remoto relate \u201cRX LOS\u201d sem que isso comprove que o transmissor tenha falhado.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a94df145\">Quando o DDM estiver dispon\u00edvel, compare a falha de transmiss\u00e3o (TX Fault) com a temperatura, a tens\u00e3o de alimenta\u00e7\u00e3o, a polariza\u00e7\u00e3o de transmiss\u00e3o (TX bias) e a pot\u00eancia de sa\u00edda de transmiss\u00e3o (TX output power) correspondentes ao mesmo carimbo de data\/hora. LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/pt\/sfp-tx-bias-current-high-causes-and-fixes\/\">Guia sobre a corrente de polariza\u00e7\u00e3o de transmiss\u00e3o (TX) do SFP<\/a> explica por que um aviso de desvio, a queda na pot\u00eancia de transmiss\u00e3o e a falha de transmiss\u00e3o, quando considerados em conjunto, s\u00e3o mais informativos do que um valor isolado.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d768143c\">N\u00e3o reinicie nem conecte a quente repetidamente um m\u00f3dulo de produ\u00e7\u00e3o apenas para limpar o sinalizador. Siga o procedimento do host e do m\u00f3dulo, preserve as evid\u00eancias originais e utilize um intervalo de manuten\u00e7\u00e3o aprovado.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-b479039e\">O RX LOS n\u00e3o \u00e9 o mesmo que um alarme de pot\u00eancia do RX<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1c6fdc12\"><a href=\"https:\/\/members.snia.org\/document\/dl\/25916\" target=\"_blank\" rel=\"noopener\">SFF-8472 Rev. 12.5a<\/a> define os estados de falha de transmiss\u00e3o (TX Fault) e perda de sinal de recep\u00e7\u00e3o (RX LOS) digitalmente, separadamente dos indicadores opcionais de alarme e aviso para temperatura, tens\u00e3o, polariza\u00e7\u00e3o de transmiss\u00e3o (TX bias), pot\u00eancia de transmiss\u00e3o (TX power) e pot\u00eancia \u00f3ptica recebida. Al\u00e9m disso, torna o monitoramento por software opcional.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-16f56dd5\">Essa distin\u00e7\u00e3o \u00e9 importante:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><code>RX LOS<\/code> \u00e9 uma indica\u00e7\u00e3o do estado do sinal.<\/li>\n\n\n\n<li><code>Aviso de bateria fraca do RX Power<\/code> compara um valor monitorado com um limite de alerta programado.<\/li>\n\n\n\n<li><code>Alarme de baixa pot\u00eancia do RX<\/code> \u00e9 um indicador de limiar mais grave.<\/li>\n\n\n\n<li>O valor exibido em dBm \u00e9 uma leitura de diagn\u00f3stico amostrada, com precis\u00e3o e m\u00e9todo de relat\u00f3rio espec\u00edficos do m\u00f3dulo.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d7abb9a3\">Os limiares e o comportamento n\u00e3o precisam ser id\u00eanticos. Um m\u00f3dulo pode relatar ter recebido alguma pot\u00eancia mesmo sem reconhecer um sinal aceit\u00e1vel para o PMD e a taxa selecionados. Por outro lado, um host pode n\u00e3o indicar uma perda de sinal de recep\u00e7\u00e3o (RX LOS) mesmo quando utiliza internamente o pino de status f\u00edsico.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-91948d7c\">Use os produtos da LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/pt\/what-is-ddm-dom-in-sfp-transceivers\/\">Guia de campo do DDM\/DOM<\/a> para obter um panorama completo. Compare a pot\u00eancia de transmiss\u00e3o (TX) local com a pot\u00eancia de recep\u00e7\u00e3o (RX) remota para a mesma dire\u00e7\u00e3o e utilize os limites operacionais m\u00ednimo e m\u00e1ximo exatos do m\u00f3dulo. N\u00e3o existe um valor \u201cideal\u201d universal em dBm.<\/p>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-ab588b48\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-22363\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/09\/sfp-rx-los-tx-fault-workflow-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-4af6aad6\">Um fluxo de trabalho controlado para falhas de LOS e TX no RX<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-121a61f3\">1. Registre a configura\u00e7\u00e3o exata<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c974b8bc\">Salve os modelos dos hosts e das portas, as vers\u00f5es do firmware e dos drivers, os n\u00fameros de pe\u00e7a e as revis\u00f5es dos m\u00f3dulos, a codifica\u00e7\u00e3o, o PMD \u00f3ptico, a taxa configurada ou negociada, o FEC e o modo da porta. Registre simultaneamente o status de ambas as extremidades, os valores de DDM, os eventos de link e os contadores de erros.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-24c33d1f\">A indica\u00e7\u00e3o \u201cSFP\u201d, \u201cSFP+\u201d ou \u201cSFP28\u201d n\u00e3o significa necessariamente compatibilidade. O encaixe f\u00edsico, o modo SerDes do host, a codifica\u00e7\u00e3o do m\u00f3dulo, a taxa de opera\u00e7\u00e3o real e a taxa de transfer\u00eancia \u00fatil s\u00e3o fatores distintos.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-ba2b92a9\">2. Confirme o r\u00f3tulo e o estado<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d20cf8c9\">Leia a defini\u00e7\u00e3o exata da plataforma para <code>RX LOS<\/code>, <code>Detec\u00e7\u00e3o de sinal<\/code>, <code>Falha no RX<\/code>, <code>Falha TX<\/code> e <code>TX Desativar<\/code>. Aguarde at\u00e9 que o m\u00f3dulo apresente dados v\u00e1lidos ap\u00f3s a inicializa\u00e7\u00e3o e, em seguida, confirme se o status \u00e9 est\u00e1vel por meio de uma segunda leitura.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f4e7bc18\">N\u00e3o presuma que <code>1<\/code> significa sempre que est\u00e1 tudo bem ou que um \u00edcone verde no painel de controle se sobrep\u00f5e ao estado original.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-6acf6eef\">3. Mapeie os dois sentidos<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-052bc45f\">Escreva o link como dois caminhos:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>A TX \u2192 B RX<\/strong><\/li>\n\n\n\n<li><strong>B TX \u2192 A RX<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-39258fdd\">Se B tiver perda de sinal de recep\u00e7\u00e3o (RX LOS), verifique o primeiro caminho. Se B apresentar falha de transmiss\u00e3o (TX Fault) e A tiver perda de sinal de recep\u00e7\u00e3o (RX LOS), as duas observa\u00e7\u00f5es coincidem quanto ao <strong>B TX \u2192 A RX<\/strong> essa dire\u00e7\u00e3o e tornam o lado de transmiss\u00e3o de B um candidato mais prov\u00e1vel. Eles ainda n\u00e3o descartam um problema de alimenta\u00e7\u00e3o do host, a desativa\u00e7\u00e3o da transmiss\u00e3o (TX Disable) ou uma segunda falha.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-be76f0b7\">4. Verificar a correspond\u00eancia \u00f3ptica<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6029bfdf\">Confirme a taxa e o PMD, a categoria da fibra, o comprimento de onda, a fam\u00edlia do conector e o polimento, a polaridade duplex ou o emparelhamento BiDi, bem como a janela de pot\u00eancia de recep\u00e7\u00e3o em cada dire\u00e7\u00e3o. N\u00e3o basta que o conector se encaixe.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-cea0e60b\">Inspecione e limpe os conectores acess\u00edveis seguindo o procedimento aprovado pelo propriet\u00e1rio da rede. O <a href=\"https:\/\/foa.org\/tech\/ref\/testing\/test\/scope.html\" target=\"_blank\" rel=\"noopener\">Guia de conectores da Associa\u00e7\u00e3o de Fibra \u00d3ptica<\/a> explica como a contamina\u00e7\u00e3o causa perdas e reflet\u00e2ncia e pode se transferir entre ferrolhos acoplados. Nunca olhe diretamente para dentro de uma fibra ou porta \u00f3ptica; utilize um medidor de pot\u00eancia adequado e um m\u00e9todo de inspe\u00e7\u00e3o por v\u00eddeo.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-59a1521d\">5. Isolar um componente<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-af1656ae\">Durante uma janela de manuten\u00e7\u00e3o aprovada, substitua por um cabo de conex\u00e3o ou m\u00f3dulo que se saiba estar em boas condi\u00e7\u00f5es e que atenda \u00e0s especifica\u00e7\u00f5es corretas, e repita as mesmas observa\u00e7\u00f5es. Se a falha ocorrer em um \u00fanico m\u00f3dulo entre portas compat\u00edveis, isso refor\u00e7a a hip\u00f3tese do m\u00f3dulo. Se o RX LOS permanecer em uma \u00fanica dire\u00e7\u00e3o da fibra, inspecione esse trajeto. Se permanecer em uma \u00fanica porta do host, investigue o host e a configura\u00e7\u00e3o.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f8dcf4e9\">Um loopback local pode reduzir o caminho local, mas somente ap\u00f3s a correspond\u00eancia entre o PMD, a fibra, o conector e a pot\u00eancia do receptor. O LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/pt\/how-to-test-an-sfp-port-with-a-fiber-loopback\/\">guia de teste de loopback de fibra \u00f3ptica<\/a> explica as limita\u00e7\u00f5es: um loop bem-sucedido n\u00e3o testa o tronco de produ\u00e7\u00e3o nem o par remoto, e um loop passivo n\u00e3o constitui um teste geral v\u00e1lido para \u00f3pticas BiDi de comprimentos de onda complementares.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-eca936c6\">6. Verifique o tr\u00e1fego, n\u00e3o apenas o status<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f165184f\">Ap\u00f3s o status ser desmarcado, verifique se o estado do link est\u00e1 est\u00e1vel, a taxa real e as novas varia\u00e7\u00f5es nos contadores em ambas as dire\u00e7\u00f5es. O fato de o RX LOS estar desmarcado indica apenas que essa indica\u00e7\u00e3o espec\u00edfica de perda n\u00e3o est\u00e1 ativa. Isso n\u00e3o comprova que os quadros Ethernet estejam livres de erros nem que a taxa de transfer\u00eancia esteja dentro do esperado.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2d5d1d13\">Se a conex\u00e3o estiver ativa, mas os erros de FCS\/CRC aumentarem, siga as instru\u00e7\u00f5es do LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/pt\/sfp-crc-errors-with-normal-rx-power-what-to-check\/\">Lista de verifica\u00e7\u00e3o para solu\u00e7\u00e3o de problemas do CRC do SFP<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-72dab416\">Erros comuns a evitar<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Substituir o receptor de B simplesmente porque B informa que o RX est\u00e1 sem linha de vis\u00e3o<\/li>\n\n\n\n<li>Considerar o TX Disable como prova de falha do TX<\/li>\n\n\n\n<li>Leitura dos valores locais de TX e RX como uma \u00fanica dire\u00e7\u00e3o \u00f3ptica<\/li>\n\n\n\n<li>Trocar as duas lentes e os dois cabos de conex\u00e3o de uma s\u00f3 vez<\/li>\n\n\n\n<li>Utilizar um valor gen\u00e9rico de comprimento de onda ou uma regra em dBm em vez dos dados exatos das fichas t\u00e9cnicas<\/li>\n\n\n\n<li>Declarar sucesso quando o alarme \u00e9 desativado sem verificar o tr\u00e1fego e os contadores<\/li>\n\n\n\n<li>Ignorando as configura\u00e7\u00f5es do SerDes do host, da taxa de transmiss\u00e3o, da FEC, da codifica\u00e7\u00e3o, do firmware ou da porta<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5795d495\">Este fluxo de trabalho n\u00e3o \u00e9 um guia de registro de PON. Um Stick ONU PON de 2,5G cont\u00e9m a l\u00f3gica da ONU e pode apresentar um comportamento diferente em rela\u00e7\u00e3o ao host. Um host SFP+ de 1G\/10G pode oper\u00e1-lo a 1G somente quando tanto o Stick quanto o host suportarem um modo 1G compat\u00edvel; algumas portas SFP+ podem suportar 2,5G apenas com o chipset\/PHY, firmware ou driver adequados, configura\u00e7\u00f5es de porta, codifica\u00e7\u00e3o do m\u00f3dulo e modo de host do Stick corretos.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-4454f2f7\">Onde os equipamentos da LuLeey se encaixam<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9a4475c4\">Para um teste multimodo local controlado, o LuLeey\u2019s <a href=\"https:\/\/www.luleey.com\/pt\/produto\/fiber-optic-loopback-lc-upc-om3-mm\/\">Loopback de fibra LC\/UPC OM3<\/a> A p\u00e1gina indica um caminho multimodo de 50\/125 \u00b5m, interface LC\/UPC e perda de inser\u00e7\u00e3o n\u00e3o superior a 0,2 dB. Essas especifica\u00e7\u00f5es n\u00e3o o tornam universal. O valor refere-se \u00e0 perda m\u00e1xima, e n\u00e3o a uma atenua\u00e7\u00e3o de prote\u00e7\u00e3o garantida; verifique o valor exato de PMD e a entrada m\u00e1xima do receptor antes de montar um loop curto.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-15a60686\">Para uma substitui\u00e7\u00e3o ou verifica\u00e7\u00e3o de compatibilidade, envie \u00e0 LuLeey os modelos de ambos os hosts, as etiquetas e revis\u00f5es dos m\u00f3dulos, o firmware, o modo da porta, os detalhes da fibra e do conector, os estados de falha de transmiss\u00e3o (TX Fault), perda de sinal de recep\u00e7\u00e3o (RX LOS) e desativa\u00e7\u00e3o de transmiss\u00e3o (TX Disable) em ambas as extremidades, instant\u00e2neos completos do DDM, carimbos de data e hora dos eventos de link e as varia\u00e7\u00f5es dos contadores.<\/p>","protected":false},"excerpt":{"rendered":"<p>Status exibido no dispositivo B O que o m\u00f3dulo est\u00e1 informando Primeiro aspecto a ser analisado O que isso n\u00e3o comprova RX<\/p>","protected":false},"author":1,"featured_media":22362,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[886],"tags":[69,1680,1642,1669,1682,71,1681],"class_list":["post-22361","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-network-maintenance","tag-sfp","tag-loss-of-signal","tag-network-maintenance","tag-optical-troubleshooting","tag-rx-los","tag-sfp-2","tag-tx-fault"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts\/22361","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/comments?post=22361"}],"version-history":[{"count":1,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts\/22361\/revisions"}],"predecessor-version":[{"id":22372,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts\/22361\/revisions\/22372"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/media\/22362"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/media?parent=22361"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/categories?post=22361"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/tags?post=22361"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}