{"id":23308,"date":"2026-11-01T23:32:20","date_gmt":"2026-11-01T15:32:20","guid":{"rendered":"https:\/\/www.luleey.com\/?p=23308"},"modified":"2026-11-01T23:32:22","modified_gmt":"2026-11-01T15:32:22","slug":"fusion-splicer-loss-estimate-vs-otdr-why-0-00-db-can-still-fail","status":"publish","type":"post","link":"https:\/\/www.luleey.com\/pt\/fusion-splicer-loss-estimate-vs-otdr-why-0-00-db-can-still-fail\/","title":{"rendered":"Estimativa de perda do emendador de fus\u00e3o versus OTDR: por que 0,00 dB ainda pode apresentar falha"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-096e0f3f\">A <strong><a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/fusion-splicer\/\" title=\"View all posts in fusion splicer\">splicer de fus\u00e3o<\/a> loss estimate<\/strong> of 0.00 dB looks like a perfect joint. Then the <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/otdr\/\" title=\"Ver todos os posts em OTDR\">OTDR<\/a> reports 0.30 dB, 0.50 dB, or even a negative \u201cgainer\u201d at the same location. Which number should you trust?<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-70feb939\">First, identify what each instrument is actually reporting. The splicer calculates an estimate from alignment images and its internal model. An OTDR infers event loss from backscattered light. A light source and power meter measure the total end-to-end insertion loss. These values are related, but they are not interchangeable.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/11\/image.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/11\/image.png\" alt=\"\" class=\"wp-image-23309\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/11\/image.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/11\/image-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/11\/image-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/11\/image-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/11\/image-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/11\/image-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-d7b6ab52\">Why a Fusion Splicer Loss Estimate Can Read 0.00 dB<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-564663f2\">A fusion splicer normally observes the prepared fiber ends, aligns the fibers, applies the arc, and analyzes the resulting image. Depending on the model, the estimate may use visible core or cladding offsets, cleave condition, fiber geometry, arc data, and an internal loss model.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a9b1f7f4\">The splicer does not send a calibrated test signal through the completed link and measure the received power at the far end. A displayed 0.00 dB can therefore mean \u201cthe calculated result rounded to 0.00 on this instrument,\u201d not \u201cthe splice has exactly zero physical loss.\u201d<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8a366d1e\">Treat the screen value as immediate process feedback. It can help catch gross alignment, cleave, contamination, or arc problems, but it is not a certification result.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Leitura<\/th><th>What it answers<\/th><th>Main limitation<\/th><\/tr><\/thead><tbody><tr><td>Splicer estimate<\/td><td>Does the joint look acceptable to this splicer and algorithm?<\/td><td>Calculated locally; not a direct transmission measurement<\/td><\/tr><tr><td>One-way OTDR event loss<\/td><td>How does the event change backscatter from one direction?<\/td><td>May show false high loss or a gainer<\/td><\/tr><tr><td><a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/bidirectional-otdr\/\" title=\"Ver todas as publica\u00e7\u00f5es sobre OTDR bidirecional\">OTDR bidirecional<\/a> average<\/td><td>What is the best field estimate of this event\u2019s loss?<\/td><td>Requires correct event pairing and signed averaging<\/td><\/tr><tr><td>OLTS\/LSPM insertion loss<\/td><td>Does the complete link meet its end-to-end budget?<\/td><td>Does not locate one individual splice<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-42451bc8\">ITU-T L.12 states that a splicer estimate or one-way OTDR can identify gross high-loss joints during construction, while actual field <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/splice-loss\/\" title=\"View all posts in splice loss\">splice loss<\/a> can be determined by averaging OTDR readings from both directions. <\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-b7d12a87\">First Check: Is the \u201cHigh Loss\u201d Only a One-Way OTDR Result?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b6c50fbb\">An OTDR measures returned Rayleigh backscatter rather than transmitted power. If the fibers on opposite sides of a splice have different mode field diameters or backscatter coefficients, the trace can step down too far in one direction and step up in the other.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9d2a55ad\">The step-up is called a gainer. The splice is not creating optical power. It is a measurement artifact caused by different backscatter levels.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ff08a24d\">Use the signed readings from the same physical splice:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Dire\u00e7\u00e3o<\/th><th>OTDR event reading<\/th><th>Interpretation<\/th><\/tr><\/thead><tbody><tr><td>A \u2192 B<\/td><td>+0.36 dB<\/td><td>Exaggerated loss may be present<\/td><\/tr><tr><td>B \u2192 A<\/td><td>\u22120.18 dB<\/td><td>Gainer in the reverse direction<\/td><\/tr><tr><td>Signed average<\/td><td>(+0.36 + \u22120.18) \u00f7 2 = <strong>0.09 dB<\/strong><\/td><td>Best estimate from this trace pair<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9855bfc3\">Do not remove the minus sign. Averaging the absolute values would incorrectly produce 0.27 dB.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8279673f\">This behavior is especially relevant when joining different single-mode fiber designs, such as G.652D and G.657A2. Corning\u2019s OTDR assessment guidance documents cases where splicer predictions remained at or below 0.01 dB while one-way OTDR results showed exaggerated loss because of MFD-related backscatter differences.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8a06cc3f\">For the fiber-specific background, see <a href=\"https:\/\/www.luleey.com\/pt\/can-you-splice-g-652d-to-g-657a2-fiber\/?utm_source=chatgpt.com\">\u00c9 poss\u00edvel fazer uma emenda entre fibras G.652D e G.657A2?<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-93170ad8\">Three Reasons the Splicer and OTDR Can Disagree<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-908fe9a8\">1. The displayed 0.00 dB is a rounded estimate<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-090a4846\">The splicer has limited display resolution and uses a model rather than a direct through-power test. A very small predicted value may display as 0.00 dB. Different models may also produce different estimates from the same joint.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-ab156b3f\">2. The OTDR result is directionally biased<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6e259a2f\">Different mode field diameters or backscatter coefficients can make a good splice look like a high-loss event from one end and a gainer from the other. A one-way result is not the actual splice loss.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-722672ab\">3. Real loss appeared outside the estimate<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9ecb4e26\">Genuine excess loss can result from contamination, a bad cleave, alignment error, the wrong splice program, poor arc conditions, a bubble, tapering, or damaged fiber.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-26eacd3a\">Loss may also appear after the splice leaves the camera view\u2014for example, when the protection sleeve is heated, the fiber is pinched in the tray, or a tight bend is introduced.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-df913036\">The OTDR may also be marking the wrong event. A nearby connector, mechanical splice, bend, splitter, or reflective fault can be mistaken for the fusion splice if route distances are not mapped correctly.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-5ca5777e\">Um fluxo de trabalho de resolu\u00e7\u00e3o de problemas em sete etapas<\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-f9bf77b5\">1. Preserve the evidence before cutting the splice<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9a91ae68\">Save the splicer record, fiber images, program name, estimated loss, cleave angles, date, operator, and splice ID. Save the original OTDR trace rather than only a screenshot.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a91dcbec\">Record the wavelength, range, pulse width, averaging time, event threshold, index setting, launch cable, receive cable, and test direction.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-80e49317\">2. Confirm that both tools refer to the same physical event<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d5b0f511\">Match the event to route drawings, cable markings, splice enclosure, tray, and fiber number. The same splice appears at a different distance when measured from the opposite end.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-30b19071\">Check whether the event is reflective. A normal fusion splice is usually non-reflective. A clear reflection may indicate a connector, mechanical gap, contaminated interface, or incorrect event assignment. ITU-T L.12 states that a measurable spike from a confirmed fusion splice requires remake.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-7bd699df\">3. Repeat the OTDR test from both ends<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4330b07c\">Use the same wavelength and compatible range, pulse width, averaging, and analysis method. Use clean, suitable launch and receive cables.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-139ad503\">Avoid changing several settings between directions. A long-pulse automatic trace and a short-pulse manually analyzed trace may not form a valid pair.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-7689a47e\">4. Average the signed event readings<\/h3>\n\n\n\n<div class=\"wp-block-wd-image wd-block-image wd-23775996\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" class=\"wp-image-23310\" src=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/11\/fusion-splicer-loss-troubleshooting-flow-1000x1000-1.png\" alt=\"\" title=\"\" srcset=\"https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/11\/fusion-splicer-loss-troubleshooting-flow-1000x1000-1.png 1000w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/11\/fusion-splicer-loss-troubleshooting-flow-1000x1000-1-800x800.png 800w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/11\/fusion-splicer-loss-troubleshooting-flow-1000x1000-1-400x400.png 400w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/11\/fusion-splicer-loss-troubleshooting-flow-1000x1000-1-768x768.png 768w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/11\/fusion-splicer-loss-troubleshooting-flow-1000x1000-1-12x12.png 12w, https:\/\/www.luleey.com\/wp-content\/uploads\/2026\/11\/fusion-splicer-loss-troubleshooting-flow-1000x1000-1-150x150.png 150w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/div>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3a118a4b\">Pair the same physical splice and calculate:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-053fa24e\"><code>Bidirectional splice loss = (A\u2192B reading + B\u2192A reading) \u00f7 2<\/code><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3a2b6119\">Keep a negative gainer value negative. If one direction is high and the reverse result is negative by a similar amount, backscatter mismatch is probably influencing the result. If both directions are high and positive, a real defect is more likely.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-4550424f\">5. Check the tray and protection before re-splicing<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6c2c6fce\">Inspect the joint and nearby fiber for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>A sleeve that is bent, twisted, or not centered<\/li>\n\n\n\n<li>Fiber pinched under a cover or retaining tab<\/li>\n\n\n\n<li>A tight turn at the splice holder<\/li>\n\n\n\n<li>Buffer-tube pressure<\/li>\n\n\n\n<li>A sharp transition into the tray<\/li>\n\n\n\n<li>Loss that increases at the longer test wavelength<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ed8e515f\">Correct routing only under the approved handling procedure, then repeat the measurements. Do not assume every post-splice loss is inside the fused glass.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-2eb6295f\">6. Re-splice only when evidence indicates a real problem<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5102aa45\">If the bidirectional average fails the project limit, the confirmed splice is reflective, the image shows a true defect, or the protected joint has been damaged, cut out and remake it under the approved procedure.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1406f027\">For the remake:<\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li>Confirm both fiber types, coatings, and the documented splice program.<\/li>\n\n\n\n<li>Strip and clean with the approved materials.<\/li>\n\n\n\n<li>Make a fresh cleave and reject contaminated or visibly defective end faces.<\/li>\n\n\n\n<li>Clean the V-grooves, clamps, and camera area as specified by the manual.<\/li>\n\n\n\n<li>Check the cleaver blade position and condition.<\/li>\n\n\n\n<li>Correr <a style=\"color: #FF6A00;\" target=\"_blank\" href=\"https:\/\/www.luleey.com\/pt\/tag\/arc-calibration\/\" title=\"View all posts in arc calibration\">arc calibration<\/a> when required by the exact splicer manual, environment, or maintenance state.<\/li>\n\n\n\n<li>Inspect electrode condition and follow the model-specific maintenance procedure.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-96a3073f\">AFL\u2019s official troubleshooting guide lists poor cleaning, bad end faces, bubbles, V-groove or camera contamination, worn electrodes, uncalibrated arc power, incorrect programs, and unsuitable parameters among possible causes of high estimated loss. It also treats calibration procedures as model-specific.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1c5e521a\">Do not repeatedly apply an extra arc simply to reduce the displayed number. Additional arcs can worsen some splices.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ee0fea9f\">For preparation, the verified <a href=\"https:\/\/www.luleey.com\/pt\/produto\/s09-high-precision-optical-fiber-cleaver\/?utm_source=chatgpt.com\">LuLeey S09 cleaver page<\/a> lists an average cleave angle below 0.5\u00b0 and support for 250 \u00b5m, 900 \u00b5m, and 3.0 mm single-fiber constructions. The cleave length must still match the exact splicer and holder requirement.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-151709db\">7. Retest the event and the complete link<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-32a47626\">Repeat the bidirectional OTDR test after the repair or routing correction. Then use the project\u2019s approved OLTS or light-source-and-power-meter method when the complete link must be certified.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-58383404\">Corning distinguishes these roles: OTDR traces locate and characterize events, but they do not replace Tier 1 end-to-end attenuation testing with an OLTS\/LSPM. <a href=\"https:\/\/www.corning.com\/catalog\/coc\/documents\/misc\/LAN-1561-AEN.pdf?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">corning.com<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-bad0c7cb\">Fast Decision Table<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Evid\u00eancias<\/th><th>Most likely meaning<\/th><th>Pr\u00f3xima a\u00e7\u00e3o<\/th><\/tr><\/thead><tbody><tr><td>Splicer 0.00 dB; one-way result high; reverse is a gainer<\/td><td>Directional backscatter\/MFD artifact may dominate<\/td><td>Average signed readings before remaking<\/td><\/tr><tr><td>Splicer 0.00 dB; both directions high<\/td><td>Real splice loss, bend, or wrong event is likely<\/td><td>Inspect mapping and tray; re-splice if the averaged result fails<\/td><\/tr><tr><td>Splicer 0.00 dB; reflective spike<\/td><td>Not a normal simple fusion-splice signature<\/td><td>Confirm event identity and inspect for a gap, connector, or defective joint<\/td><\/tr><tr><td>Splicer estimate high; bidirectional result passes<\/td><td>Estimation, image, or maintenance issue may exist<\/td><td>Inspect equipment; do not fail the link from the estimate alone<\/td><\/tr><tr><td>OTDR events pass; OLTS link loss fails<\/td><td>Cumulative loss, connector\/reference issue, bend, or another event<\/td><td>Troubleshoot the complete link<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-de6e5a63\">What to Send for a Useful Technical Review<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-94d61bd0\">\u201cThe splicer says 0.00\u201d is not enough evidence. Send:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Exact splicer model, firmware, splice program, and maintenance state<\/li>\n\n\n\n<li>Fiber types and cable part numbers on both sides<\/li>\n\n\n\n<li>Original splicer images and records<\/li>\n\n\n\n<li>Original A\u2192B and B\u2192A OTDR trace files<\/li>\n\n\n\n<li>OTDR wavelength, pulse, range, averaging, thresholds, and launch\/receive cables<\/li>\n\n\n\n<li>Event distance from each end<\/li>\n\n\n\n<li>Photos of the protected splice and tray routing<\/li>\n\n\n\n<li>End-to-end OLTS\/LSPM result, if available<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3413060d\">LuLeey can then help distinguish a preparation issue from an OTDR artifact or application mismatch. Use the <a href=\"https:\/\/www.luleey.com\/pt\/contact-us\/?utm_source=chatgpt.com\">LuLeey contact page<\/a> and include the exact equipment model and trace files.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-fd809d5a\">Pr\u00f3ximo passo pr\u00e1tico<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f4c55f4b\">Do not cut out a splice because one instrument shows a surprising number. First map the event, test from both ends, and average the signed OTDR readings.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-faaf8137\">If the bidirectional result still fails\u2014or the event is reflective, visibly defective, or mechanically stressed\u2014repair the cause, make a fresh splice, and retest the complete link.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-997cee8f\">Refer\u00eancias oficiais<\/h3>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.itu.int\/rec\/dologin_pub.asp?id=T-REC-L.12-200005-S!!PDF-E&amp;lang=e&amp;type=items&amp;utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">ITU-T L.12: Optical fibre joints<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.corning.com\/content\/dam\/corning\/catalog\/coc\/documents\/application-notes\/AN3060.pdf?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Corning AN3060: Guidance for OTDR Assessment of Fusion Spliced Single-Mode Fibers<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/learn.aflglobal.com\/_pfcdn\/assets\/preprocessed\/11221\/dbdf55c9-3246-42c1-9b9b-97f0610bab9b\/dbdf55c9-3246-42c1-9b9b-97f0610bab9b.92e046c3-a933-447f-8e98-f44d65042f19?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">AFL AN-3035: 90S+ Splicer Error Code and Troubleshooting Quick Guide<\/a><\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>Reading What it answers Main limitation Splicer estimate Does the joint look acceptable to this splicer and algorithm? Calculated locally;<\/p>","protected":false},"author":1,"featured_media":23309,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1077],"tags":[58,1797,1507,1800,1796,1798,1799],"class_list":["post-23308","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-problem-cases","tag-otdr","tag-arc-calibration","tag-bidirectional-otdr","tag-fiber-cleaving","tag-fusion-splicer","tag-gainer-event","tag-splice-loss"],"_links":{"self":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts\/23308","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/comments?post=23308"}],"version-history":[{"count":1,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts\/23308\/revisions"}],"predecessor-version":[{"id":23311,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/posts\/23308\/revisions\/23311"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/media\/23309"}],"wp:attachment":[{"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/media?parent=23308"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/categories?post=23308"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luleey.com\/pt\/wp-json\/wp\/v2\/tags?post=23308"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}