كابل توزيع من MPO إلى FC UPC، كابل توزيع مكون من 8 ألياف أحادية النمط من نوع MPO/MTP إلى FC/UPC
USD $40.99 USD $79.99نطاق السعر: من USD $40.99 خلال USD $79.99
- خصومات تلقائية للشركات الصغيرة
- يمكنك مزج ومطابقة منتجات الكابلات والمقسمات المؤهلة:
- 10 عناصر أو أكثر → وفر 10%
- 20 قطعة أو أكثر → وفر 12%
The Luleey MPO to FC UPC Cable is a high-performance 8 Fiber MPO Cable designed to connect MPO/MTP backbone cabling to FC/UPC fiber interfaces. Built with single mode fiber, this MPO Breakout Cable provides low insertion loss, stable return loss, and reliable optical performance for telecom networks, optical distribution frames, fiber communication systems, and equipment room cabling.
This MPO to FC Fanout Cable uses one MPO/MTP connector on one end and 8 FC/UPC connectors on the other, making it suitable for structured fiber distribution, local area networks, wide area networks, optical test systems, and single mode fiber infrastructure. Luleey provides factory-tested MPO Cable assemblies for clean deployment, stable transmission, and long-term network reliability.
عملية دفع آمنة ومضمونة

نظرة عامة على المنتج
The Luleey MPO to FC UPC Cable is an 8-fiber single mode breakout cable designed for fiber optic networks that require FC/UPC connector interfaces. It converts one MPO/MTP interface into eight FC/UPC fiber connections, allowing engineers to distribute backbone fiber links into individual FC ports efficiently.
This 8 Fiber MPO Cable is built with single mode fiber for long-distance optical communication and stable network transmission. It is commonly used in telecom systems, optical distribution frames, local area networks, wide area networks, fiber communication systems, equipment rooms, test instruments, and structured fiber cabling projects.
Compared with using multiple individual FC patch cords, an MPO Breakout Cable helps reduce cable congestion, simplify installation, improve fiber organization, and make maintenance easier in high-density optical network environments.
صُممت مجموعات كابلات MPO من Luleey لتوفير أداء بصري موثوق به، وتركيب منظم، وتكوين عملي وفقًا لمتطلبات كل مشروع.
الميزات
- MPO/MTP to 8 × FC/UPC breakout cable design
- 8-fiber single mode construction
- Designed for FC/UPC fiber interfaces
- خسارة إدخال منخفضة لضمان استقرار الإرسال الضوئي
- UPC polished connectors for standard single mode optical links
- الموصل «أ» قابل للتكوين ليكون من النوع الذكري أو الأنثوي من طراز MPO/MTP
- يدعم الموصل «أ» خيارات صقل الألياف من نوع UPC أو APC
- خيارات قطبية MPO من النوع A والنوع B والنوع C
- Suitable for telecom networks and optical distribution systems
- Compatible with fiber patch panels, ODF systems, and test equipment
- غلاف LSZH لضمان أمان أكبر عند التركيب في الأماكن المغلقة
- تم اختبارها في المصنع من قِبل شركة Luleey للتأكد من أدائها البصري
- Available in multiple cable lengths for flexible project deployment
التطبيقات
- شبكات الاتصالات
- صناديق التوزيع البصرية
- أنظمة الاتصالات الليفية
- Local Area Networks
- Wide Area Networks
- توصيلات غرفة المعدات
- Optical Test Instruments
- توزيع الألياف الضوئية في المكتب المركزي
- Commercial Building Fiber Cabling
- Single Mode Fiber Infrastructure
المواصفات
| المعلمة | القيمة |
|---|---|
| العلامة التجارية | لولوي |
| نوع المنتج | MPO/MTP to FC/UPC Breakout Cable |
| الموصل أ | MPO/MTP ذكر أو أنثى، UPC أو APC اختياري |
| الموصل ب | 8 × FC/UPC |
| عدد الألياف | 8 ألياف |
| نوع الألياف | الألياف أحادية النمط |
| طول الموجة الاختباري | 1310 نانومتر / 1550 نانومتر |
| نطاق الطول الموجي التشغيلي | فوق 1310 نانومتر |
| خسارة الإدخال في MPO | القيمة النموذجية ≤0.20 ديسيبل، القيمة القصوى ≤0.70 ديسيبل |
| خسارة الإدخال في موصل FC | القيمة النموذجية ≤0.20 ديسيبل، القيمة القصوى ≤0.30 ديسيبل |
| خسارة العودة | UPC ≥50 ديسيبل |
| قطبية MPO | النوع أ / النوع ب / النوع ج (اختياري) |
| متانة التزاوج في MPO | 500 مرة أو أكثر |
| متانة التوصيل بين الموصلات | 1000 مرة أو أكثر |
| قوة الشد | ≥120 نيوتن |
| درجة حرارة التشغيل | من -20 درجة مئوية إلى +70 درجة مئوية |
| درجة حرارة التخزين | من -20 درجة مئوية إلى +70 درجة مئوية |
| طول الكابل | 1 م / 3 م / 5 م / 10 م / 15 م / 20 م (اختياري) |
ملاحظات حول تكوين الموصلات
This MPO to FC UPC Cable uses FC/UPC connectors on the fanout side. Connector A can be selected according to the project requirement, including MPO/MTP male or female options and UPC or APC polish options.
تشمل خيارات التكوين المتاحة ما يلي:
| المنصب | الخيارات المتاحة |
|---|---|
| الموصل أ | MPO/MTP: موصل APC أنثوي، موصل UPC أنثوي، موصل APC ذكري، موصل UPC ذكري |
| الموصل ب | 8 × FC/UPC |
| قطبية MPO | النوع أ، النوع ب، النوع ج |
For standard FC/UPC single mode cabling, engineers should confirm connector gender, MPO polarity, and mating interface before ordering. UPC and APC connectors should not be mixed unless the optical system is specifically designed for that configuration.
Why Use an MPO to FC UPC Cable?
An MPO to FC UPC Cable is useful when high-density MPO/MTP backbone cabling needs to connect with FC/UPC-based optical equipment, patch panels, ODF systems, or test instruments.
FC connectors use a threaded coupling structure, which provides secure mechanical stability in equipment rooms, optical test environments, and telecom distribution systems.
The 8-fiber breakout design allows one MPO/MTP connector to be distributed into eight FC/UPC connections, reducing cable clutter and improving fiber management compared with multiple separate FC patch cords.
FC UPC vs FC APC: Which One Should You Choose?
FC/UPC and FC/APC connectors are both used in single mode fiber networks, but they serve different optical requirements.
| نوع الموصل | الأفضل لـ |
|---|---|
| FC/UPC | Standard single mode links, LAN/WAN fiber, test equipment, telecom distribution |
| FC/APC | Reflection-sensitive links, CATV, GPON, XGS-PON, long-distance optical systems |
Choose the MPO to FC UPC Cable when your equipment uses standard FC/UPC interfaces and does not require ultra-low reflection APC polishing.
Choose the FC/APC version when the link is sensitive to back reflection or when the connected equipment specifically requires APC connectors.
لماذا يُستخدم كابل توزيع MPO؟
يتيح كابل التوزيع MPO توزيع موصل MPO/MTP واحد عالي الكثافة على عدة موصلات ألياف فردية.
تشمل المزايا ما يلي:
- تنظيم مسار الكابلات بشكل أفضل
- تركيب أسرع
- تقليل الازدحام في الرفوف
- إدارة أسهل لملفات ODF
- تنظيم أفضل للألياف
- توسيع الشبكة بشكل أكثر قابلية للتوسع
For telecom rooms, equipment rooms, and optical distribution systems, the Luleey 8 Fiber MPO Cable provides a clean and efficient method for managing multiple FC/UPC fiber connections.
الأسئلة الشائعة
What is an MPO to FC UPC Cable?
An MPO to FC UPC Cable is a fiber breakout assembly that converts one MPO/MTP connector into multiple FC/UPC connectors for single mode fiber distribution.
ما هي استخدامات كابل MPO ذي 8 ألياف هذا؟
It is commonly used in telecom networks, optical distribution frames, local area networks, wide area networks, optical test systems, and equipment room cabling.
What does MPO to FC Fanout Cable mean?
It means one MPO/MTP connector is distributed into multiple FC connectors, making fiber breakout and distribution easier.
What is the difference between FC UPC and FC APC?
FC/UPC is commonly used for standard single mode fiber links, while FC/APC provides lower back reflection and is better for reflection-sensitive systems such as CATV, GPON, and long-distance optical links.
هل هذا كابل MPO أحادي الوضع؟
نعم. يستخدم هذا المنتج الألياف أحادية النمط في أنظمة الاتصالات الضوئية والبنية التحتية للألياف الضوئية لمسافات طويلة.
ما هي خيارات القطبية المتاحة؟
تتوفر خيارات القطبية من النوع A والنوع B والنوع C وفقًا لتصميم كابلات الشبكة.
هل يمكن أن يكون الموصل «أ» ذكراً أم أنثى؟
نعم. يمكن اختيار الموصل «أ» ليكون من النوع الذكري أو الأنثوي من نوع MPO/MTP، حسب واجهة التوصيل المقابلة.
هل يمكن لموصل «أ» استخدام كابلات UPC أو APC؟
نعم. يدعم الموصل «أ» خيارات الصقل UPC أو APC. يجب على المهندسين التأكد من نوع الصقل المطلوب قبل تقديم الطلب.
هل يمكن لشركة Luleey توفير كابلات بأطوال مخصصة؟
نعم. يمكن لشركة Luleey توفير كابلات بأطوال مختلفة وتكوينات موصلات متنوعة وفقًا لمتطلبات المشروع.
لماذا تختار مجموعات الكابلات MPO من Luleey؟
Luleey MPO Cable assemblies are factory tested and designed for stable optical performance, clean cable management, and reliable deployment in telecom, enterprise, and optical distribution environments.
يجب عليك تسجيل الدخول لنشر مراجعة.
سؤال وجواب
كابل توزيع من MPO إلى FC UPC، كابل توزيع مكون من 8 ألياف أحادية النمط من نوع MPO/MTP إلى FC/UPC
| الوزن | 0.25 كيلوجرام |
|---|---|
| الأبعاد | 10 × 10 × 10 سنتيميتر |
| الموصل أ | MTP/MPO (أنثى) APC, MTP/MPO (أنثى) UPC, MTP/MPO (ذكر) APC, MTP/MPO (ذكر) UPC |
| الموصل ب | نادي يو بي سي لكرة القدم |
| نوع MPO | النوع أ, النوع ب, النوع C |
| نوى MPO | 8 |
| مادة كابل MPO | OS2 |
| طول الكابل | 10 أمتار, 15 م, 1 م, 20 مترًا, 3 أمتار, 5 أمتار |






















































SFP/SFP+ (1G/2.5G/5G/10G)
SFP-T (1 جيجابت/2.5 جيجابت/10 جيجابت)
كابل AOC 10G/25G/40G/100G
كابل DAC 10G/25G/40G/100G
QSFP28، QSFP+، SFP28، 100G/40G/25G
محولات الوسائط من النحاس إلى الألياف الضوئية
لوحة PCBA لمحول الوسائط الليفية
محولات الوسائط الليفية من OEO
محولات الوسائط من التسلسلية إلى الألياف الضوئية
محولات الوسائط من الفيديو إلى الألياف الضوئية
وحدة ONU GPON/EPON بسعة 1000 ميغابت/ثانية
وحدة ONU لشبكة EPON بسرعة 10 جيجابت/ثانية/XG-PON/XGS-PON
وحدة ONU من نوع STICK SFP بتقنية 2.5G GPON/XPON
وحدة ONU لشبكات POE GPON/EPON
جهاز ONT لاسلكي من نوع GPON/EPON
EPON OLT
وحدة OLT لشبكة GPON
وحدة SFP PON
المفاتيح الصناعية
المحولات المُدارة
محولات POE
المحولات غير المُدارة
كابلات الألياف الضوئية من نوع MTP/MPO
خراطيش الألياف الضوئية
حلقة إرجاع الألياف الضوئية
الكابلات البصرية وأطراف الألياف الضوئية
المقسمات الضوئية وصندوق المقسم
موصلات ذات شفة ليفية
المحولات البصرية
مخفف ضوئي
الموصل السريع ولوحة الموصلات
مضخم إشارة كابل التلفزيون (CATV)
جهاز استقبال ضوئي لشبكة الكابل التلفزيوني (CATV)
جهاز تحديد مواقع الأعطال البصري
OTDR
مقياس الطاقة الضوئية
جهاز تحديد الألياف الضوئية
منظفات الألياف الضوئية
مقصات الألياف ومقشرات الألياف
الأدوات النحاسية
المراجعات
There are no reviews yet