MPO to SC APC Cable, 16 Fiber OS2 Single Mode Breakout Cable
EUR €69.34
- Automatic discounts for small businesses
- Mix & Match eligible Cables and Splitters products:
- 10+ items → Save 10%
- 20+ items → Save 12%
The Luleey MPO to SC APC Cable breaks out one 16-fiber MPO/MTP connection into sixteen SC/APC simplex connectors for OS2 single mode fiber distribution.
- 1 × 16-fiber MPO/MTP to 16 × SC/APC simplex connectors
- OS2 single mode fiber construction
- SC/APC connectors with high return loss
- MPO/MTP male or female options
- MPO/MTP APC or UPC options
- Type A, Type B and Type C polarity options
- MPO insertion loss: typical ≤0.20dB, maximum ≤0.70dB
- SC insertion loss: typical ≤0.20dB, maximum ≤0.30dB
- APC return loss ≥60dB
- LSZH cable jacket
- Factory tested at 1310nm and 1550nm
- Suitable for telecom, PON, ODF and high-density fiber distribution
Guaranteed Safe Checkout

Product Overview
The MPO to SC APC Cable is a 16-fiber OS2 single mode breakout cable designed to distribute one high-density MPO/MTP interface into sixteen individual SC/APC fiber connections.
One end uses a 16-fiber MPO/MTP connector, while the breakout side provides sixteen SC/APC simplex connectors. This configuration allows multiple single mode fiber channels to be routed through one compact MPO backbone cable and then separated into individual SC/APC interfaces at the equipment, patch panel or optical distribution frame.
The SC/APC connectors use angled physical contact polishing to provide high return loss and reduced back reflection, making the cable especially suitable for reflection-sensitive single mode applications such as PON networks, CATV systems, telecom infrastructure, optical distribution frames and fiber testing systems.
Compared with installing sixteen individual long-distance patch cords, the 16-fiber MPO breakout design helps reduce backbone cable congestion, simplify routing and improve fiber organization.
Connector A can be configured with MPO/MTP male or female gender and APC or UPC polishing according to the mating interface. Type A, Type B and Type C polarity options are available for different cabling designs.
Because MPO gender, polishing and polarity directly affect compatibility, the connector configuration and fiber mapping should be confirmed before ordering.
Key Features
- 16-fiber high-density breakout design
- One MPO/MTP interface to sixteen SC/APC connectors
- OS2 single mode optical fiber
- Low insertion loss for stable optical transmission
- SC/APC interface for low-reflection single mode applications
- MPO/MTP male and female options
- MPO/MTP APC and UPC polish options
- Type A, Type B and Type C polarity configurations
- LSZH low-smoke zero-halogen jacket
- Factory tested at 1310nm and 1550nm
- High tensile strength for structured cabling installation
- Suitable for high-density telecom and fiber distribution systems
Typical Applications
- Optical Distribution Frames
- Telecom Fiber Distribution
- GPON and XGS-PON Infrastructure
- CATV Optical Networks
- Central Office Fiber Cabling
- Equipment Room Cabling
- Fiber Patch Panels
- Single Mode Backbone Distribution
- Optical Test Systems
- Building-to-Building Fiber Links
- High-Density Fiber Management
- MPO/MTP Backbone Breakout
Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | Luleey |
| Product Type | MPO/MTP to SC/APC Breakout Cable |
| Fiber Count | 16 Fibers |
| Fiber Type | OS2 Single Mode |
| Connector A | MPO/MTP Male or Female |
| Connector A Polish | APC or UPC Optional |
| Connector B | 16 × SC/APC Simplex |
| MPO Polarity | Type A / Type B / Type C |
| Test Wavelength | 1310nm / 1550nm |
| MPO Insertion Loss | Typical ≤0.20dB, Maximum ≤0.70dB |
| SC Connector Insertion Loss | Typical ≤0.20dB, Maximum ≤0.30dB |
| SC/APC Return Loss | ≥60dB |
| MPO/APC Return Loss | ≥60dB |
| MPO/UPC Return Loss | ≥50dB |
| MPO Mating Durability | ≥500 Cycles |
| SC Connector Mating Durability | ≥1000 Cycles |
| Tensile Strength | ≥120N |
| Cable Jacket | LSZH |
| Operating Temperature | -20°C to +70°C |
| Storage Temperature | -20°C to +70°C |
| Standard Cable Length | 1m |
| Custom Length | Available on Request |
Connector Configuration
Before ordering, confirm the MPO/MTP interface used by your equipment or patch panel.
Connector A options
MPO/MTP Female APC
MPO/MTP Female UPC
MPO/MTP Male APC
MPO/MTP Male UPC
Connector B
16 × SC/APC Simplex
MPO/MTP male and female connectors are not interchangeable when the mating hardware requires a specific pin configuration.
APC and UPC polishing should also match the mating interface. Do not directly mate an MPO/APC connector with an MPO/UPC interface.
MPO Polarity Selection
The cable is available with Type A, Type B and Type C polarity configurations.
The correct polarity depends on the fiber mapping required by the connected equipment and cabling system.
For a 16-fiber breakout cable, customers should confirm the required MPO-to-SC channel mapping before ordering, especially when the cable is being integrated into an existing MPO backbone.
If the polarity or fiber mapping is unknown, provide the connection diagram or the equipment interface information before production.
Why Use a 16 Fiber MPO Breakout Cable?
A 16-fiber MPO breakout cable combines sixteen individual optical fibers into one compact MPO backbone interface.
Instead of routing sixteen separate long fiber patch cords through a rack, cabinet or cable tray, one MPO cable can carry the fibers to the distribution point and then break them out into sixteen individual SC/APC connections.
This provides several practical advantages:
- Reduced backbone cable congestion
- Cleaner rack and cabinet organization
- Faster multi-fiber installation
- Easier fiber identification and maintenance
- Higher fiber density
- Simplified ODF and patch-panel deployment
The design is particularly useful when many SC/APC interfaces need to connect to an MPO-based backbone.
Why SC/APC?
SC/APC connectors use an angled polished end face designed to reduce optical back reflection.
This makes SC/APC commonly used in applications such as:
- GPON
- XGS-PON
- CATV
- FTTH infrastructure
- Telecom optical distribution
- Reflection-sensitive optical measurement systems
SC/APC should be connected to another APC interface. It should not be directly mated with SC/UPC.
OS2 Single Mode Fiber
This cable uses OS2 single mode fiber for single mode optical infrastructure.
It is suitable for backbone fiber distribution and longer-distance optical links when used with compatible optical equipment.
Actual transmission distance and data rate depend on the optical transceivers, wavelength, optical power budget and complete link design rather than the passive cable alone.
Factory Optical Testing
Each cable assembly is tested for optical performance before shipment.
Testing is performed at 1310nm and 1550nm to verify insertion loss and connection quality.
Published limits include:
MPO/MTP insertion loss: maximum ≤0.70dB
SC connector insertion loss: maximum ≤0.30dB
SC/APC return loss: ≥60dB
For project orders requiring individual test results, confirm the testing and documentation requirements before ordering.
How to Choose the Correct Configuration
Check the following before placing an order:
Fiber Count: 16 Fibers
Fiber Type: OS2 Single Mode
Connector B: 16 × SC/APC
MPO Gender: Male or Female
MPO Polish: APC or UPC
Polarity: Type A, Type B or Type C
Cable Length: 1m standard or custom length
Selecting the correct MPO gender, polishing and polarity is important because these parameters must match the existing MPO/MTP interface.
You must be logged in to post a review.
Q & A
MPO to SC APC Cable, 16 Fiber OS2 Single Mode Breakout Cable
| Weight | 0.25 kg |
|---|---|
| Dimensions | 10 × 10 × 10 cm |
| Connector A | MTP/MPO (Female) APC, MTP/MPO (Female) UPC, MTP/MPO (Male)APC, MTP/MPO (Male)UPC |
| Connector B | SC APC |
| MPO Type | TYPE A, TYPE B, TYPE C |
| MPO cores | 16 |
| MPO Cable Material | OS2 |
| Cable Length | 1m |





















































SFP/SFP+ (1G/2.5G/5G/10G)
SFP-T (1G/2.5G/10G)
AOC Cable 10G/25G/40G/100G
DAC Cable 10G/25G/40G/100G
QSFP28 QSFP+ SFP28 100G/40G/25G
Copper to Fiber Media Converters
Fiber Media Converter PCBA Board
OEO Fiber Media Converters
Serial to Fiber Media Converters
Video to Fiber Media Converters
1000M GPON/EPON ONU
10G EPON ONU/XG-PON/XGS-PON
2.5G GPON/XPON STICK SFP ONU
POE GPON/EPON ONU
Wireless GPON/EPON ONT
EPON OLT
GPON OLT
SFP PON Module
Industrial Switches
Managed Switches
POE Switches
Unmanaged Switches
MTP/MPO Fiber Cables
Fiber Optic Cassettes
Fiber Optic Loopback
Optic Cables and Fiber Pigtails
Optical Splitters and Splitter Box
Fiber Flange Connectors
Optical Adapters
Optical Attenuator
Quick Connector and Connector Panel
CATV Amplifier
CATV Optical Receiver
Visual Fault Locator
OTDR
Optical Power Meter
Fiber Optic Identifier
Fiber Optic Cleaners
Fiber Cleavers & Fiber Strippers
Copper Tools
Reviews
There are no reviews yet